Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 102 for “"Ionization Source"”.

  1. Microengineered mass spectrometer with field emission ionization source

    … 1cm by 1cm, where one is a cathode electron source and the other is the ion collector. External ion sources are not needed. Electrons are emitted from the array of cathode tips by field emission. Gas molecules near the cathode are bombarded by electrons and ionized. An electrostatic field and …

    njit Repository record for Microengineered mass spectrometer with field emission ionization source (opens in a new tab)

  2. An Imaging Mass Spectrometer with Ultrashort Laser Pulses as its Ionization Source

    … adapted for ultrashort laser pulses as its ionization technique, as an alternative to other imaging techniques. Before my arrival, the mass spectrometer has only been subject to preliminary tests on noble gases. Since then, we’ve made some modifications to the system in order to properly …

    ottawa-retro Repository record for An Imaging Mass Spectrometer with Ultrashort Laser Pulses as its Ionization Source (opens in a new tab)

  3. Portable, Solid-Phase Microextraction Low Temperature Plasma Ionization Source for Mass Spectrometry

    … and selectivity. However, all known MS ionization methods are significantly hindered by ion suppression that is caused by the competition for charge between analytes of interest and other species present in the sample matrix. To approach this key problem without using chromatography …

    unsw Repository record for Portable, Solid-Phase Microextraction Low Temperature Plasma Ionization Source for Mass Spectrometry (opens in a new tab)

  4. Effects of a Heavy Particle External Ionization Source on Carbon-Dioxide Laser Discharges

    Made available in DSpace on 2014-12-10T19:07:02Z (GMT). No. of bitstreams: 1 7309937.pdf: 2573057 bytes, checksum: cb6a073921655fbca8a6ba8a3aa80739 (MD5) Previous issue date: 1972

    uiuc Repository record for Effects of a Heavy Particle External Ionization Source on Carbon-Dioxide Laser Discharges (opens in a new tab)

  5. Surface Acoustic Wave Nebulization as a Mass Spectrometry Ionization Source, Characterization and Application

    … of SAWN is lower compare to electrospray ionization (ESI). To improve the SAWN performance, a standing wave SAWN chip was designed and fabricated. The droplet size of standing wave SAWN was measured and is in general smaller than progressive wave SAWN. The standing wave SAWN design …

    washington Repository record for Surface Acoustic Wave Nebulization as a Mass Spectrometry Ionization Source, Characterization and Application (opens in a new tab)

  6. DEVELOPMENT OF A MINIATURIZED AMBIENT GLOW DISCHARGE IONIZATION SOURCE AND ITS APPLICATION IN ELEMENTAL AND MOLECULAR ANALYSIS

    … (LS-APGD) was first developed as an excitation source for atomic emission spectroscopy, it has been improved upon and demonstrated as an ionization source for elemental mass spectrometry, molecular mass spectrometry, and ambient desorption mass spectrometry. Multiple functions coming from one …

    clemson Repository record for DEVELOPMENT OF A MINIATURIZED AMBIENT GLOW DISCHARGE IONIZATION SOURCE AND ITS APPLICATION IN ELEMENTAL AND MOLECULAR ANALYSIS (opens in a new tab)

  7. DEVELOPMENT OF ROBUST AND SENSITIVE NANO-ELECTROSPRAY IONIZATION SOURCE WITH NOVEL MULTI-CHANNEL EMITTER COUPLED WITH MASS SPECTROMETRY

    Nanoelectrospray ionization (nanoESI) provides high sensitivity due to increased desolvation efficiencies developed through the production of nanometer sized droplets. Unfortunately, this sensitivity is often traded for poor robustness and reproducibility, where conventional nanospray …

    queens Repository record for DEVELOPMENT OF ROBUST AND SENSITIVE NANO-ELECTROSPRAY IONIZATION SOURCE WITH NOVEL MULTI-CHANNEL EMITTER COUPLED WITH MASS SPECTROMETRY (opens in a new tab)

  8. Evaluation and Optimization of a Liquid-Sampling Atmospheric Pressure Glow Discharge Ionization Source for Diverse Applications in Mass Spectrometry

    … requires instrumentation capable of hard ionization, such as inductively coupled plasma mass spectrometry (ICP-MS) and thermal ionization mass spectrometry (TIMS). These instruments also require very high-resolution mass analyzers so isobaric elemental isotopes can be clearly resolved and …

    clemson Repository record for Evaluation and Optimization of a Liquid-Sampling Atmospheric Pressure Glow Discharge Ionization Source for Diverse Applications in Mass Spectrometry (opens in a new tab)

  9. Liquid Sampling–Atmospheric Pressure Glow Discharge Ionization Source Coupled to an Ultra High Resolution Orbitrap Mass Spectrometer for Diverse Spectrochemical Analysis

    … analysis and an atmospheric pressure chemical ionization source coupled to a mass spectrometer. However, with the LS-APGD, a simple switch in the carrier solution allows for these analyses. The International Atomic Energy Agency (IAEA) sets international target values (ITVs) for measurement …

    clemson Repository record for Liquid Sampling–Atmospheric Pressure Glow Discharge Ionization Source Coupled to an Ultra High Resolution Orbitrap Mass Spectrometer for Diverse Spectrochemical Analysis (opens in a new tab)

  10. Progress Towards Uranium Isotope Ratio Measurements Directly from Cotton Swipes with the Liquid Sampling – Atmospheric Pressure Glow Discharge (LS-APGD) Ionization Source

    … – atmospheric pressure glow discharge (LS-APGD) ionization source is a novel microplasma ionization source capable of ionizing a diverse set of both inorganic and organic chemical species including, ionic metal constituents as well as ligated metallic species, polyaromatic hydrocarbons (PAH), …

    clemson Repository record for Progress Towards Uranium Isotope Ratio Measurements Directly from Cotton Swipes with the Liquid Sampling – Atmospheric Pressure Glow Discharge (LS-APGD) Ionization Source (opens in a new tab)

  11. Diverse Mass Spectrometric Couplings and Applications of the Liquid Sampling–Atmospheric Pressure Glow Discharge as a Combined Atomic and Molecular Ionization Source

    … operate as a combined atomic and molecular (CAM) ionization source, the first of its kind. The LS-APGD operates using < 100 µL min-1 liquid flow and < 1 L min-1 He sheath gas, allowing for reduced operational overhead relative to many other ionization sources. Even with these unique merits behind …

    clemson Repository record for Diverse Mass Spectrometric Couplings and Applications of the Liquid Sampling–Atmospheric Pressure Glow Discharge as a Combined Atomic and Molecular Ionization Source (opens in a new tab)

  12. Identification and Validation of Protein Biomarkers for Invasive Aspergillosis; Development of Surface-Induced Dissociation Device and Paper Spray Ionization Source for Protein Complex Studies

    … on instrument development to improve current ionization and dissociation technologies for characterizing topology and substructure of protein complexes. Part I of this dissertation describes the identification and validation of protein biomarkers for Invasive Aspergillosis (IA), a fatal …

    arizona-thes Repository record for Identification and Validation of Protein Biomarkers for Invasive Aspergillosis; Development of Surface-Induced Dissociation Device and Paper Spray Ionization Source for Protein Complex Studies (opens in a new tab)

  13. Development of an electrospary ionization source and vacuum interface for guided ion beam tandem mass spectrometry experiments: structural and energetic effects in the molecular recognition of amino acids by 18-crown-6

    Absolute 18-crown-6 (18C6) binding affinities of the side chains of AAs in peptides and proteins were determined in a step by step fashion using guided ion beam tandem mass spectrometry techniques. Firstly, 18C6 binding affinities of several peptidomimetic bases (B) that serve as mimics of the side …

    wayne-thes Repository record for Development of an electrospary ionization source and vacuum interface for guided ion beam tandem mass spectrometry experiments: structural and energetic effects in the molecular recognition of amino acids by 18-crown-6 (opens in a new tab)

  14. Development of microplasmas and analysis of complex biomolecules using plasma and synchrotron radiation

    In this work, a microplasma-based ionization source for ambient mass spectrometry (AMS) has been developed. Optical emission spectroscopy, optical microscopy, and electrical measurements have been used to characterize the discharge. The discharge was used in a direct exposure mode in AMS …

    gatech Repository record for Development of microplasmas and analysis of complex biomolecules using plasma and synchrotron radiation (opens in a new tab)

  15. Extreme ultraviolet laser ionization mass spectrometry: probing materials at the micro and nano scales

    … "bench-top" scale. Herein I show how EUV laser ionization can be used with different types of mass spectrometers as a new route for interrogating nuclear and geologic materials with micro and nano scale lateral spatial resolution. I focus on the application of a compact capillary discharge EUV …

    colostate Repository record for Extreme ultraviolet laser ionization mass spectrometry: probing materials at the micro and nano scales (opens in a new tab)

Page 1 of 6