Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 58 for “"Ionization chambers"”.
-
Saturation characteristics of ionization chambers
… characteristics of two types of parallel plate ionization chambers - the free -air chamber and the extrapolation chamber. Despite the great importance of free-air chambers in standardising laboratories, little theoretical consideration seems to have been given to their saturation losses. The …
-
Investigation of radiation quality with differential ionization chambers
… Two ratios were measured: (a) the ratio of the ionization current in a copper-lined ionization chamber to the ionization current in a lucite-wall chamber, (b) the ratio of the ionization current in the copper-lined chamber to the ionization current in the same lucite-wall chamber with the latter …
-
The evaluation of electret ionization chambers as a field screening method for samples containing natural and depleted Uranium
<p>Electret ionization chambers have been experimentally evaluated as a field screening method for samples containing natural and depleted uranium. Correlation factors relating the electret's response to uranium standards were experimentally determined and tested. The method was tested on unknown …
-
The evaluation of thermally stimulated exoelectron emission detectors and electret ionization chambers for the purpose of measuring tritium on surfaces
… (TSEE) detector. The other type is the Electret Ionization Chamber (EIC). Both types of detectors were studied for linearity and reproducibility using a solid, 100 cm<sup>2</sup> tritium source (NIST traceable). Three variations of TSEE detectors were evaluated: Thin Film BeO, Ceramic BeO …
-
Investigation of exposure rate discrepancies between energy compensated Geiger Mueller tubes and pressurized ionization chambers due to muon and anti-muon cosmic particles
… Geiger Mueller (GM) tubes and pressurized ionization chambers are two types of gas filled detectors that measure radiation dose or exposure but operate on different physical principles. Energy compensated GMs are gaining popularity because they are less expensive and more durable than …
-
An ionization chamber technique for the measurement of the transverse spin dependence of the proton-proton total cross-section
High precision ionization chambers were designed end built to measure the transverse spin dependence of the proton-proton total cross-section difference in the 318 MeV to 8 MeV energy region. Severe microphonic noise was minimized by mounting one of the chambers on pneumatic vibration isolators. …
-
Development of a Hybrid Alanine-calorimetry Absorbed-dose Standard for Linac Electron Beams
… calibrating alanine against secondary standard ionization chambers, with calibrations traceable to primary standard water calorimeter measurements in high-energy electron beams, and subsequently using alanine in low-energy electron beams to determine absorbed dose. Ionization chambers calibrated …
-
Ανάπτυξη Monte Carlo προσομοιώσεων και δοσιμετρικών υπολογισμών σε σύγχρονα συστήματα γραμμικών επιταχυντών με ενσωματωμένο μαγνητικό τομογράφο (MR-Linacs)
… Subsequently, the dead volume of a variety of ionization chambers was determined, and its impact on computational dosimetry was assessed. As a next step, the k_(B,Q) correction factors for a 10×10cm2 reference field were calculated. The ionization chambers were positioned in four main …
-
Απόκριση ανιχνευτών ελέγχου ραδιενέργειας περιβάλλοντος στη γήινη και κοσμική ακτινοβολία
… of a network of 24 Reuter-Stokes high-pressure ionization chambers (HPIC) detectors that measure dose rate and geographically cover the whole territory of Greece. The response of the Reuter-Stokes detectors to terrestrial and cosmic radiation was evaluated in comparison with spectroscopic data …
-
Ανάπτυξη διαδικασιών και μεθόδων για τη ραδιοβιολογική μελέτη και τον ποιοτικό έλεγχο σύγχρονων τεχνικών ακτινοθεραπείας
… were determined for an extensive range of ionization chambers and dosimetry diodes, a microDiamond detector, TLDs, and alanine pellets using a comprehensive MC model of the GK Perfexion unit. Calculations were performed for the Solid Water (SW) and Acrylonitrile Butadiene Styrene (ABS) …
-
High-energy induced fission theory and application.
… The construction of two types of bismuth-fission ionization chambers is described in detail The operating characteristics of one such chamber, the CR-5, containing thirty grams of bismuth, are listed. A brief review of cosmic ray phenomena is included which points to the field wherein this type of …
-
The electronic response of 2,2,4,4 tetramethylpentane to minimum ionizing particles
… have been suggested as a detection media for ionization chambers in hadronic calorimeters as a means of improving their energy resolution. In this thesis, the performance of a parallel plate (with 1 cm separation) ionization chamber using room temperature 2,2,4,4 TMP was studied using minimum …
-
Ανάπτυξη μεθόδων για την βελτιστοποίηση και τον ποιοτικό έλεγχο σύγχρονων τεχνικών βραχυθεραπείας
… develop a QA protocol based on pixel-segmented ionization chambers (PIXSICs) that would enable all QA tests (source calibration, source positioning, and irradiation time) to be performed in an integrated and unified manner. This would eliminate the need for multiple equipment items, reduce the …
-
Accelerator systems and instrumentation for the NuMI neutrino beam
… beam includes arrays of radiation-tolerant ionization chambers downstream of the decay volume. These arrays detect the remnant hadrons and tertiary muons produced with the neutrinos. This thesis discusses measurements using the arrays, including diagnostics of potential beam errors and …
-
Development and evaluation of a Monte Carlo code system for analysis of ionization chamber responses
… code system for calculating the response of an ionization chamber to a mixed neutron and photon radiation environment. The resulting code system entitled MICAP - a Monte Carlo Ionization Chamber Analysis Package - determines the neutron, photon, and total responses of the ionization chamber to …
-
Kilo-Voltage X-Ray Correction Factors for In-Water Measurements Based on TG-61
… an in-water measurement which is based on ionization chambers calibrated in air in terms of air kerma. The variation of the overall correction factor (PQ;cham) and its components (known as corrections for the change in the chamber response due to the change in the spectrum distribution in …
-
Die versyfering van historiese kosmiese straal-data = The digitization of historic cosmic-ray data
… was recorded using the model C cosmic-ray ionization chamber which uses a Lindemann electrometer. The shadow of the electrometer needle was projected onto a continuously moving strip of 60 mm photographic paper. Hour markers were recorded by dimming the lamp for three minutes at the start …
-
Proposed model of thermionically assisted breakdown and implementation on electrostatic thrusters
… multiplication are proposed to be multistep ionization and neutralization of the space charge by ions. Breakdown criteria and a means of estimating the reduction is breakdown voltage requirement are derived. One proposal for the thermionically assisting emission device is the coiled-coil …
-
An x-ray dose comparator
… an x-ray field. Essentially, it consists of two ionization chambers each fed into a very stable, linear, d.c. amplifier. The outputs of the d.c. amplifiers are coupled in such a way that a fraction of the output of one amplifier is balanced against the total output of the other in a ratio …
Page 1 of 3