Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 13 of 13 for “"Ionization current"”

  1. Investigation of radiation quality with differential ionization chambers

    … Two ratios were measured: (a) the ratio of the ionization current in a copper-lined ionization chamber to the ionization current in a lucite-wall chamber, (b) the ratio of the ionization current in the copper-lined chamber to the ionization current in the same lucite-wall chamber with the latter …

    ubc Repository record for Investigation of radiation quality with differential ionization chambers (opens in a new tab)

  2. Using Plasmas for High-Speed Flow Control and Combustion Control

    … studies of chemiluminescence and chemi-ionization for flame emission and combustion control have been discussed. Pulsed DC and pulsed RF actuator discharge power measurements and plasma temperature measurements demonstrated that rapid localized heating, at a rate of 1000 degrees C / 10 …

    ohiolink Repository record for Using Plasmas for High-Speed Flow Control and Combustion Control (opens in a new tab)

  3. DISCOVERY AND CHARACTERIZATION OF LOW CURRENT ELECTROSPRAY MODES FOR MASS SPECTROMETRY: APPLICATIONS FOR FEMTOESI AND THE ENHANCEMENT OF RELATIVE IONIZATION EFFICIENCY

    The analysis of analytes using electrospray ionization (ESI) and mass spectrometry (MS) has become a widely used tool for the detection and characterization of a wide class of chemical species. Because of its utilization for liquid phase sample and its application to a wide range of flow rates, …

    unh-thes Repository record for DISCOVERY AND CHARACTERIZATION OF LOW CURRENT ELECTROSPRAY MODES FOR MASS SPECTROMETRY: APPLICATIONS FOR FEMTOESI AND THE ENHANCEMENT OF RELATIVE IONIZATION EFFICIENCY (opens in a new tab)

  4. Investigation of the Fundamentals of Electrospray Ionization and the Separation of Small Molecules using Ion Mobility Mass Spectrometry

    … solution-phase oligomeric distributions during ionization. Gas-phase ions in IM-MS are typically formed using electrospray ionization (ESI), which is a gentle ionization source that preserves noncovalent interactions. One challenge in ESI is that multiple analytes in a single droplet can …

    washington Repository record for Investigation of the Fundamentals of Electrospray Ionization and the Separation of Small Molecules using Ion Mobility Mass Spectrometry (opens in a new tab)

  5. Design and installation of a field ionization test chamber for ion thrusters

    … utilization of carbon nanotube arrays for field ionization in ion thrusters allows for a substantial reduction in thruster size and weight. The availability of miniature ion thrusters may enable the development of a suitable propulsion system for nano- and picosatellites, and can realize …

    nps Repository record for Design and installation of a field ionization test chamber for ion thrusters (opens in a new tab)

  6. Development and experimental validation of a knock induced damage model and real-time implementation of model-based strategies to control knock intensity in boosted gasoline engines

    … and potentially during the engine design. Ionization current signal capabilities have been investigated to fully replace the pressure sensor, to develop a robust on-board close-loop combustion control strategy, both in knock-free and knock-limited conditions. Water injection is a powerful …

    bologna Repository record for Development and experimental validation of a knock induced damage model and real-time implementation of model-based strategies to control knock intensity in boosted gasoline engines (opens in a new tab)

  7. Gallium film formation by ion cluster beam deposition

    … films was under the strong influence of the ionization current; the higher the degree of ionization, the higher the degree of film crystallinity. It also was found that less efficient ionization, due to a decrease in the effective cluster ionization cross section with electron velocity, …

    njit Repository record for Gallium film formation by ion cluster beam deposition (opens in a new tab)

  8. A comparison of some methods of estimating radium

    … weight of the sample and (2) measurement of the ionization current produced by the emanation in a calibrated electroscope. Granting that we have accurate methods of separating radium emanation, the other problem of measuring the ionization of current and the calibration of the electroscopes for …

    missouri Repository record for A comparison of some methods of estimating radium (opens in a new tab)

  9. Investigation of the feasibility of sensing transient velocity by means of gaseous ionization

    … as the ratio of the fractional change of gas ionization current to the fractional change of gas pressure. A maximum obtainable sensitivity was calculated, S<sup>i</sup><sub>p</sub>]<sub>max</sub> = -0.309 A/B V, where A, B are constants for a given gas within a particular range of …

    vt Repository record for Investigation of the feasibility of sensing transient velocity by means of gaseous ionization (opens in a new tab)

  10. Strong-field induced plasma formation in solid dielectrics

    … mechanisms - strong-field and electron-impact ionization - to the generation of an electron-hole plasma in strong-field driven solid dielectrics. The first two chapters of this thesis are dedicated to a theoretical description of the fundamental, ultrafast, light-matter interaction and …

    fu-berlin Repository record for Strong-field induced plasma formation in solid dielectrics (opens in a new tab)

  11. Saturation characteristics of ionization chambers

    … characteristics of two types of parallel plate ionization chambers - the free -air chamber and the extrapolation chamber. Despite the great importance of free-air chambers in standardising laboratories, little theoretical consideration seems to have been given to their saturation losses. The …

    edinburgh Repository record for Saturation characteristics of ionization chambers (opens in a new tab)

  12. Application de la chimiluminescence de flamme et du courant d’ionisation à la surveillance de l’état de combustion pour une chaudière à gaz domestique

    Les variations de la composition des gaz naturels nécessitent un system de réglage automatique de la richesse de flamme pour des chaudières domestiques à gaz. Dans ce travail,deux solutions potentielles sont étudiées, à savoir la chimiluminescence de flamme et le courant d’ionisation. Des …

    star-france Repository record for Application de la chimiluminescence de flamme et du courant d’ionisation à la surveillance de l’état de combustion pour une chaudière à gaz domestique (opens in a new tab)