Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 13 of 13 for “"Ionization quenching"”
-
3D Scintillator Detector Quenching Characterization For Scanning Proton Beams
… the scintillators’ response depends on the ionization density of the incident radiation, termed ionization quenching. For protons and other heavy charged particles, the ionization density, which is quantified as the linear energy transfer (LET), varies as a function of depth. Therefore, …
-
The High Energy Telescope on Solar Orbiter
… that the non-linearity in light output, called ionization quenching, is independent of temperature in case of the scintillation material used in HET. Ionization quenching originates from high ionization densities in the scintillation material when detecting heavy ions. The results are published …
-
Characterization of electroluminescence signals from nuclear recoil events in the dual-phase argon time projection chamber of the red experiment with convolutional autoencoders
… by detecting both prompt scintillation light and ionization charge, with the latter measured through delayed electroluminescence signals. While conventional WIMP searches focus on masses around hundreds of GeV/c2, interest has recently expanded to lighter WIMPs, down to 1 GeV/c2. The properties of …
-
Characterization of electroluminescence signals from nuclear recoil events in the dual-phase argon Time Projection Chamber of the Red experiment with Convolutional Autoencoders
… by detecting both prompt scintillation light and ionization charge, with the latter measured through delayed electroluminescence signals. While conventional WIMP searches focus on masses around hundreds of GeV/c2, interest has recently expanded to lighter WIMPs, down to 1 GeV/c2. The properties of …
-
Phenomenological Studies and Analysis Techniques to Search for Light Dark Matter With NEWS-G
… must face. The possibility of measuring the ionization quenching factor of gases with a neutron capture experiment is explored, but ultimately ruled-out. A likelihood analysis framework is implemented for NEWS-G, and validated through a case-study of the neutrino floor. Finally, the …
-
Energy non-linearity studies and pulse shape analysis of liquid scintillator signals in the Double Chooz experiment
… the non-linear scintillator response caused by ionization quenching and Cerenkov light has to be accurately reproduced in the Monte Carlo. To this end the relevant properties of the liquid scintillators are investigated experimentally and theoretically. For the data analysis the pulse shape of …
-
Optimization, simulation and analysis of the scintillation signals in the Double Chooz experiment
… measurements and Monte Carlo tuning of the ionization quenching effect for electrons and alpha particles. In addition, simulations of the position dependent detector light collection efficiency led to an inhomogeneity correction method. The detector response timing was studied for alphas and …
-
The SNO+ liquid scintillator response to low-energy electrons and its effect on the experiment’s sensitivity to a future neutrinoless double beta decay signal
… scintillator response to low-energy electrons. Ionization quenching of low-energy electrons in the tellurium-loaded liquid scintillator is small, with Birks’ constant measured to be kB = (4.1 ± 2.9) × 10−6 cm/keV.
-
SPOT SCANNING PROTON BEAMS CHARACTERIZATION VIA PLASTIC SCINTILLATOR DETECTOR
… are steep — conditions that push conventional ionization chambers beyond their reliable operating range. Plastic scintillation detectors offer a potential solution. Their sub-millimeter active volumes avoid the volume-averaging effects over larger chambers, and their very high temporal …
-
Study and detection of low energy neutrinos
… of the experimental set up, to calculate the ionization yield inside the gaseous volume and to study the shielding response to background radiation. Apart from the GEANT4 simulation, a new method was developed for the calculation of the mean ionization potential and the Fano factor of low …
-
Measurement of proton and alpha-particle quenching in LAB based scintillators and determination of spectral sensitivities to supernova neutrinos in the SNO+ detector
… measurement of the Alpha-particle and proton quenching parameters of loaded and unloaded LAB is described. These parameters are crucial for an efficient background suppression, necessary to reach a sensitivity above the current limit in 76Ge of T1/2(0v) > 2.1 x 10^(25) y (90% C.L.). For 0.3% …
-
In Vivo Dosimetry Using Plastic Scintillation Detectors For External Beam Radiation Therapy
… made with an ion chamber and radiochromic film. Ionization quenching, an under-response due to densely ionizing radiation, was found to be responsible for a 7% loss of signal at the highest energy studied (250 MeV) and a 10% loss at the lowest (140 MeV). The under-response was found to be …
-
SEARCH FOR NON-STANDARD NEUTRINO INTERACTIONS WITH LARGE-VOLUME LIQUID SCINTILLATOR DETECTORS
… provide a conservative measurement of the Birks’ ionization quenching constant kB and discuss problems related to its measurement. Throughout the study, I also formulate the optimal characteristics of the experimental apparatus for this improvement. The ultimate goal of this investigation is …