Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 43 for “"Ionization sources"”.

  1. Improved ionization sources and detection methods for analytical mass spectrometry

    <p>A new time-of-flight mass spectrometer (TOF-MS) has been developed for direct characterization of solid samples and fundamental studies. A N[subscript]2 laser ([lambda] = 337 nm) was used with the linear TOF-MS to study ion formation from various solid specimens. Improved techniques were …

    iastate Repository record for Improved ionization sources and detection methods for analytical mass spectrometry (opens in a new tab)

  2. The use of dopants in atmospheric pressure ionization sources of mass spectrometers

    Dopants, as “ionization assisting” chemicals, have been used in different ionization techniques. However, they have been used most frequently in the field of Atmospheric Pressure Photoionization (APPI). These chemicals that have high photoabsorption and photoionization cross sections easily get …

    ubc Repository record for The use of dopants in atmospheric pressure ionization sources of mass spectrometers (opens in a new tab) Download PDF for The use of dopants in atmospheric pressure ionization sources of mass spectrometers (opens in a new tab)

  3. Fundamental Studies and Applications of Ambient Plasma Ionization Sources for Mass Spectrometry

    The field of ambient desorption/ionization mass spectrometry (ADI-MS) has existed for over a decade. ADI-MS is a technique that offers benefits including fast analysis time, simple ionization sources that are easily constructed, and little to no required sample preparation. The research presented …

    byu Repository record for Fundamental Studies and Applications of Ambient Plasma Ionization Sources for Mass Spectrometry (opens in a new tab) Download PDF for Fundamental Studies and Applications of Ambient Plasma Ionization Sources for Mass Spectrometry (opens in a new tab)

  4. Characterization of an atmospheric pressure ion lens for electrospray ionization sources in mass spectrometry

    … and improve the operation of electrospray ionization (ESI) sources for mass spectrometry (MS). This work is in part motivated by the inefficient transmission of ions from atmospheric pressure into vacuum, characteristic of current electrospray ion source designs. The first chapter of this …

    ubc Repository record for Characterization of an atmospheric pressure ion lens for electrospray ionization sources in mass spectrometry (opens in a new tab) Download PDF for Characterization of an atmospheric pressure ion lens for electrospray ionization sources in mass spectrometry (opens in a new tab)

  5. A study of optical properties and current emission processes of gas phase field ionization sources

    Field emission ion sources are extremely important for producing high-resolution ion beams essential for several fields of research and especially for semiconductor manufacturing. Although most sources used are based on liquid metals they cannot produce beams of H, He or other noble gases, so that …

    maryland Repository record for A study of optical properties and current emission processes of gas phase field ionization sources (opens in a new tab)

  6. Conventional inductively coupled plasma (ICP) and novel microwave inductively coupled atmospheric pressure plasma (MICAP) as ionization sources for trace elemental analysis

    … Coupled Atmospheric Pressure Plasma (MICAP) as ionization source for elemental analysis, evaluating their analytical performance and applications when coupled with the optical emission spectrometer and mass spectrometer. Chapter 1 provides an overview of the fundamental concepts and basic …

    iastate Repository record for Conventional inductively coupled plasma (ICP) and novel microwave inductively coupled atmospheric pressure plasma (MICAP) as ionization sources for trace elemental analysis (opens in a new tab)

  7. Development and Characterization of Plasma-based Sources for Ambient Desorption/Ionization Mass Spectrometry

    A number of atmospheric-pressure ionization sources for mass spectrometry has recently appeared in the literature to yield a field that is collectively referred to as Ambient Desorption/Ionization-Mass Spectrometry (ADI-MS). These sources include, among others, Desorption ElectroSpray Ionization …

    iu Repository record for Development and Characterization of Plasma-based Sources for Ambient Desorption/Ionization Mass Spectrometry (opens in a new tab)

  8. Flowing atmospheric pressure afterglow drift tube ion mobility spectrometry evidence discrimination

    … quality control, and biological applications. Ionization source is one of the main sections in DTIMS which ionizes neutral analyte molecules prior to any separation. Ionization sources such as Corona Discharge (CD), Electrospray (ESI), Radioactive (63Ni) been coupled to DTIMS; however, …

    ttu Repository record for Flowing atmospheric pressure afterglow drift tube ion mobility spectrometry evidence discrimination (opens in a new tab)

  9. LIPIDOMIC PROFILING OF DICTYOSTELIUM DISCOIDEUM

    … mass spectrometers equipped with electrospray ionization sources were used to identify these complex lipids.

    iupui Repository record for LIPIDOMIC PROFILING OF DICTYOSTELIUM DISCOIDEUM (opens in a new tab)

  10. Diverse Mass Spectrometric Couplings and Applications of the Liquid Sampling–Atmospheric Pressure Glow Discharge as a Combined Atomic and Molecular Ionization Source

    … operate as a combined atomic and molecular (CAM) ionization source, the first of its kind. The LS-APGD operates using < 100 µL min-1 liquid flow and < 1 L min-1 He sheath gas, allowing for reduced operational overhead relative to many other ionization sources. Even with these unique merits behind …

    clemson Repository record for Diverse Mass Spectrometric Couplings and Applications of the Liquid Sampling–Atmospheric Pressure Glow Discharge as a Combined Atomic and Molecular Ionization Source (opens in a new tab)

  11. Modeling discharge and surface processes in capacitively coupled reactors

    … applications, capacitively coupled plasma (CCP) sources are widely used.</p> <p>In this work, different types of capacitively coupled plasma sources and fluorination of polypropylene in a large-area CCP source are modeled using a 2-d hybrid plasma equipment model. As improvements to the model, …

    iastate Repository record for Modeling discharge and surface processes in capacitively coupled reactors (opens in a new tab)

  12. Development Of A Field-Portable Miniature Mass Spectrometer Designed For In-Situ Analysis And Ion Trap Miniaturization

    … vacuum systems, mass analyzers, electronics, and ionization sources have allowed for the development of field-portable mass spectrometers. The performance of portable instruments has received much attention for their utility in the detection of illicit drugs, explosives, environmental …

    purdue-thes Repository record for Development Of A Field-Portable Miniature Mass Spectrometer Designed For In-Situ Analysis And Ion Trap Miniaturization (opens in a new tab)

  13. The application of beam transport theory to mass spectrometer design

    … z phase spaces are finite and that, for surface ionization sources, their magnitude is due to the initial Maxwellian velocity distribution of the thermal ions. For maximum transmission these emittances must be matched to the phase space acceptances of the magnetic analyser and collector system. A …

    anu Repository record for The application of beam transport theory to mass spectrometer design (opens in a new tab)

  14. Development of microplasmas and analysis of complex biomolecules using plasma and synchrotron radiation

    In this work, a microplasma-based ionization source for ambient mass spectrometry (AMS) has been developed. Optical emission spectroscopy, optical microscopy, and electrical measurements have been used to characterize the discharge. The discharge was used in a direct exposure mode in AMS …

    gatech Repository record for Development of microplasmas and analysis of complex biomolecules using plasma and synchrotron radiation (opens in a new tab)

  15. Applications in Opioid Analysis with FAIMS Through Control of Vapor Phase Solvent Modifiers

    … development of a continuous ambient desorption/ionization source for FAIMS, the ultrasonic nebulization corona discharge (USN-CD). Developed via modification of the USN-based modifier system, it demonstrated superior signal intensities compared to standard nano electrospray ionization sources …

    usf Repository record for Applications in Opioid Analysis with FAIMS Through Control of Vapor Phase Solvent Modifiers (opens in a new tab)

  16. CHEMICAL CHARACTERIZATION OF BOTANICAL PRODUCTS: COMPREHENSIVE SPECIATION BY LIQUID CHROMATOGRAPHY PARTICLE BEAM MASS SPECTROMETRY

    … mass spectrometry (LC-PB/MS) technique with dual ionization sources (electron ionization (EI) and glow discharge (GD)). More specifically, the catechin species in green tea and the caffeic acid derivatives in echinacea extracts have been characterized. As well, an arsenic speciation study was …

    clemson Repository record for CHEMICAL CHARACTERIZATION OF BOTANICAL PRODUCTS: COMPREHENSIVE SPECIATION BY LIQUID CHROMATOGRAPHY PARTICLE BEAM MASS SPECTROMETRY (opens in a new tab)

  17. The Space Density, Environments, and Physical Properties of Large Ly α Nebulae

    … in overdense regions. To disentangle the sources of ionization, we took a census of all the compact ionization sources within a large Ly α nebula using high resolution imaging. Finally, we used photoionization modeling to put constraints on the physical conditions, the metallicity, and the …

    arizona-thes Repository record for The Space Density, Environments, and Physical Properties of Large Ly α Nebulae (opens in a new tab)

  18. ESI-MS and EPR spin trapping study of xanthophylls: structural and environmental impacts on reactivity

    … isomers of zeaxanthin isolated from various sources in mass spectrometry using electrospray ionization sources. Zeaxanthin exhibits antioxidant activity and also plays a role in photo-protection in the retina. These properties have led to it being marketed as a dietary supplement as it is not …

    alabama Repository record for ESI-MS and EPR spin trapping study of xanthophylls: structural and environmental impacts on reactivity (opens in a new tab)

Page 1 of 3