Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 28 for “"Iterative Image Reconstruction"”.

  1. Iterative image reconstruction for optical CT radiochromic gel dosimetry

    … source to detector, necessitating the use of iterative image reconstruction techniques instead of filtered backprojection (FBP). Iterative reconstruction requires a system matrix to describe the imaging system’s geometry, but stored system matrices can become immensely large, making them …

    ubc Repository record for Iterative image reconstruction for optical CT radiochromic gel dosimetry (opens in a new tab) Download PDF for Iterative image reconstruction for optical CT radiochromic gel dosimetry (opens in a new tab)

  2. System Optimization and Iterative Image Reconstruction in Photoacoustic Computed Tomography for Breast Imaging

    … tumor can be directly quantified, therefore the images produced by such optimized imaging systems are not only visually appealing, but most informative in terms of the tumor detection task. Fourth, when imaging a large three-dimensional (3D) object such as the breast, iterative reconstruction …

    wustl Repository record for System Optimization and Iterative Image Reconstruction in Photoacoustic Computed Tomography for Breast Imaging (opens in a new tab)

  3. A Novel Methodology for Iterative Image Reconstruction in SPECT Using Deterministic Particle Transport

    … at different angles around the patient. This reconstruction can be improved by properly modeling the physics in the patient, i.e., particle absorption and scattering. Currently, such modeling is done using statistical Monte Carlo methods, but deterministic codes have the potential to offer …

    vt Repository record for A Novel Methodology for Iterative Image Reconstruction in SPECT Using Deterministic Particle Transport (opens in a new tab)

  4. Three-Dimensional Photoacoustic Computed Tomography: Imaging Models and Reconstruction Algorithms

    … of experimental designs. Meanwhile, a variety of image reconstruction algorithms have been developed for the purpose of computed tomography. Most of these algorithms assume full knowledge of the acoustic pressure function on a measurement surface that either encloses the object or extends to …

    wustl Repository record for Three-Dimensional Photoacoustic Computed Tomography: Imaging Models and Reconstruction Algorithms (opens in a new tab)

  5. Fast GPU-Based Approach to Branchless Distance-Driven Projection and Back-Projection in Cone Beam CT

    Modern CT image reconstruction algorithms rely on projection and back-projection operations to refine an image estimate in iterative image reconstruction. A widely-used state-of-the-art technique is distance-driven projection and back-projection. While the distance-driven technique yields superior …

    marquette Repository record for Fast GPU-Based Approach to Branchless Distance-Driven Projection and Back-Projection in Cone Beam CT (opens in a new tab)

  6. Image Reconstruction in Photoacoustic Computed Tomography with Acoustically Heterogeneous Media

    … hybrid imaging modality that combines optical image contrast with ultrasound detection. The majority of currently available PACT image reconstruction algorithms are based on idealized imaging models that assume a lossless and acoustically homogeneous medium. However, in many applications of …

    wustl Repository record for Image Reconstruction in Photoacoustic Computed Tomography with Acoustically Heterogeneous Media (opens in a new tab)

  7. Low-dose imaging of liver diseases through neutron stimulated emission computed tomography: Simulations in GEANT4

    … tomographic acquisition protocol followed by iterative image reconstruction. These studies have shown that moderate concentrations of iron can be detected in the liver with moderate dose levels and long scan times. However, a low-dose, reduced scan time technique to differentiate various liver …

    duke Repository record for Low-dose imaging of liver diseases through neutron stimulated emission computed tomography: Simulations in GEANT4 (opens in a new tab)

  8. Hybrid inverse problems in molecular imaging

    … non-uniqueness and stability results on the reconstruction problem under various circumstances. Moreover, we propose a few image reconstruction algorithms and perform numerical simulations using these algorithms to complement our theoretical analysis. The second inverse problem we study here …

    texas Repository record for Hybrid inverse problems in molecular imaging (opens in a new tab)

  9. Dynamic Myocardial SPECT Imaging Using Single-Pinhole Collimator Detectors: Distance-Driven Forward and Back-Projection, and KDE-Based Image Reconstruction Methods

    … encoding more information in the reconstructed images in the form of time-activity functions. The recent introduction of small solid-state SPECT cameras using multiple pinhole collimators, such as the GE Discovery NM 530c, offers the ability to obtain accurate myocardial perfusion information …

    mcmaster Repository record for Dynamic Myocardial SPECT Imaging Using Single-Pinhole Collimator Detectors: Distance-Driven Forward and Back-Projection, and KDE-Based Image Reconstruction Methods (opens in a new tab)

  10. Implementation of an analytically based scatter correction in SPECT reconstructions

    … the quality and quantitative accuracy of SPECT images. The objective of the work performed in this thesis was to develop and validate a scatter correction technique that uses an accurate physics-based model of photon scatter as part of an iterative image reconstruction algorithm. This work was …

    ubc Repository record for Implementation of an analytically based scatter correction in SPECT reconstructions (opens in a new tab) Download PDF for Implementation of an analytically based scatter correction in SPECT reconstructions (opens in a new tab)

  11. Abgrenzbarkeit von mediastinalen und hilären Lymphknoten in der kontrastverstärkten Niedrigdosis-Computertomographie des Thorax

    … 64-row multi-detector chest CT with iterative image reconstruction). Individual matching for gender (53% female), age (53 ± 19 years), body height, weight, anterior–posterior and transverse diameters of chest and lung ruled out pre-test confounders. Lymph node size (cut-off value, 1 …

    lmu-germany Repository record for Abgrenzbarkeit von mediastinalen und hilären Lymphknoten in der kontrastverstärkten Niedrigdosis-Computertomographie des Thorax (opens in a new tab)

  12. Parallel Image Reconstruction Systems for Magnetic Induction Tomography

    … the resulting magnetic field perturbations. An image of conductivity distribution within the object is reconstructed by iteratively solving a non-linear inverse problem.<br/><br/>As a relatively new imaging technique, MIT encounters several challenges both in terms of the formulation of the …

    southwales Repository record for Parallel Image Reconstruction Systems for Magnetic Induction Tomography (opens in a new tab) Download PDF for Parallel Image Reconstruction Systems for Magnetic Induction Tomography (opens in a new tab)

  13. Spatial and Temporal Image Prediction with Magnitude and Phase Representations

    … theory and techniques for spatial and temporal image prediction with the magnitude and phase representation of the Complex Wavelet Transform (CWT) or the over-complete DCT to solve the problems of image inpainting and motion compensated inter-picture prediction. First, I develop the theory and …

    rice Repository record for Spatial and Temporal Image Prediction with Magnitude and Phase Representations (opens in a new tab)

  14. Optimizing Kilovoltage Cone-Beam Computed Tomography for Image-Guided Radiation Therapy

    … (kV CBCT) has important applications in image guided radiation therapy (IGRT). In its current state, CBCT is suboptimal for these applications due to its considerable radiation dose, poor soft-tissue contrast and inaccurate Hounsfield Units as a result of in-patient scatter. The specific …

    utswmed Repository record for Optimizing Kilovoltage Cone-Beam Computed Tomography for Image-Guided Radiation Therapy (opens in a new tab)

  15. Deformable motion correction and spatial image analysis in positron emission tomography

    … awake rodents is addressed. A novel method of iterative image reconstruction is developed that incorporates correction for non-cyclic deformable motion. Point clouds were used to represent the imaged objects in the image space, and motion was accounted by using time-dependent point coordinates. …

    ubc Repository record for Deformable motion correction and spatial image analysis in positron emission tomography (opens in a new tab) Download PDF for Deformable motion correction and spatial image analysis in positron emission tomography (opens in a new tab)

  16. System Characterizations and Optimized Reconstruction Methods for Novel X-ray Imaging

    … System characteristics are analyzed or optimized reconstruction methods are proposed for these imaging modalities. In the first part, we investigated the unique properties of propagation-based phase-contrast imaging technique when combined with the X-ray tomosynthesis. Fourier slice theorem …

    wustl Repository record for System Characterizations and Optimized Reconstruction Methods for Novel X-ray Imaging (opens in a new tab)

  17. Optical Tomography Based on the Equation of Radiative Transfer

    … finger joints. The majority of currently applied image reconstruction schemes rely on the validity of the diffusion equation for the description of light propagation in tissue. Unfortunately, the diffusion equation does not accurately describe light propagation in media that contain low-scattering …

    fu-berlin Repository record for Optical Tomography Based on the Equation of Radiative Transfer (opens in a new tab)

  18. Voxel based quantitative analysis of distance dependent resolution correction in single photon emission computed tomography.

    … photon emission computed tomography (SPECT) iterative image reconstruction but how much improvement in image quality is gained by the additional computational expense associated with the correction? This work examined the effect of the correction in SPECT imaging of the human brain, firstly …

    adelaide Repository record for Voxel based quantitative analysis of distance dependent resolution correction in single photon emission computed tomography. (opens in a new tab)

  19. Deep learning-based methods for image reconstruction in cardiac CT and cardiac cine MRI

    … artery disease or cardiac dysfunction. The image reconstruction problems in these imaging modalities can be ill-posed for different reasons. For example, in low-dose CT, the measured data is noisy, while in accelerated cardiac MRI, undersampling in k-space leads to incomplete data. Thus, …

    fu-berlin Repository record for Deep learning-based methods for image reconstruction in cardiac CT and cardiac cine MRI (opens in a new tab)

Page 1 of 2