Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 163 for “"Iterative reconstruction"”.

  1. Iterative Reconstruction of Cone-Beam Micro-CT Data

    … amounts of noise. On the other hand, iterative reconstruction algorithms may offer benefits in such cases, but the computational burden associated with iterative reconstructions is prohibitive. In this work, we address this computational burden and present methods that make iterative …

    utk-theses Repository record for Iterative Reconstruction of Cone-Beam Micro-CT Data (opens in a new tab)

  2. CT dose optimization with model based iterative reconstruction

    … to assess the feasibility of using model-based iterative reconstruction (MBIR) to develop new low-dose CT (computed tomography) protocols in the areas of neck, chest, and abdominal imaging without compromising diagnostic performance. Medical imaging has become the largest source of radiation …

    cork Repository record for CT dose optimization with model based iterative reconstruction (opens in a new tab)

  3. Iterative Reconstruction Algorithms for Polyenergetic X-ray Computerized Tomography

    A reconstruction algorithm in computerized tomography is a procedure for reconstructing the attenuation coefficientscient, a real-valued function associated with the object of interest, from the measured projection data. Generally speaking, reconstruction algorithms in CT fall into two categories: …

    toronto-retro Repository record for Iterative Reconstruction Algorithms for Polyenergetic X-ray Computerized Tomography (opens in a new tab)

  4. High-quality computed tomography using advanced model-based iterative reconstruction

    … beyond current system capabilities. Model-Based Iterative Reconstruction (MBIR) techniques offer improved image quality over traditional methods by incorporating more accurate models of the imaging physics. In this work, we seek to improve image quality by including high-fidelity models of CT …

    jhu Repository record for High-quality computed tomography using advanced model-based iterative reconstruction (opens in a new tab)

  5. Investigating signal denoising and iterative reconstruction algorithms in photoacoustic tomography

    … the optical absorption map can be obtained by a reconstruction algorithm. In the linear array transducer based data acquisition system, the PA signals are contaminated with various noises. Also, the reconstruction suffers from artifacts and missing structures due to the limited detection view. We …

    ubc Repository record for Investigating signal denoising and iterative reconstruction algorithms in photoacoustic tomography (opens in a new tab) Download PDF for Investigating signal denoising and iterative reconstruction algorithms in photoacoustic tomography (opens in a new tab)

  6. Predicting Task-­specific Performance for Iterative Reconstruction in Computed Tomography

    … calculated from a series of projections using reconstruction methods. Recently introduced on clinical CT scanners, iterative reconstruction (IR) method enables potential patient dose reduction with significantly reduced image noise, but is limited by its "waxy" texture and nonlinear nature. To …

    duke Repository record for Predicting Task-­specific Performance for Iterative Reconstruction in Computed Tomography (opens in a new tab)

  7. Implementation of Iterative Reconstruction of Images from Multiple Bases Representations

    … MBR distorted images are reconstructed by the iterative method of Projection onto Convex Sets (POCS). Many constraints that form convex sets are reviewed and examined. Due to the high distortion at the block boundaries, some constraints are introduced particularly to reduce artifacts at the …

    vt Repository record for Implementation of Iterative Reconstruction of Images from Multiple Bases Representations (opens in a new tab)

  8. Iterative reconstruction of three-dimensional magnetic resonance images from boron data

    … develops a computational framework for iterative reconstruction of three-dimensional (3D) Magnetic Resonance Images (MRI) from boron data. The application is Boron Neutron Capture Therapy (BNCT) which is a promising technique for cancer treatment and MRI is used to monitor the various …

    utk-theses Repository record for Iterative reconstruction of three-dimensional magnetic resonance images from boron data (opens in a new tab)

  9. Novel methods for iterative reconstruction and noise estimation in CT imaging

    … CT scanning increasingly raises public concern. Iterative reconstruction algorithms have shown promise on improving quality of CT images with reduced radiation. In the first part of this study, a novel iterative reconstruction method is developed to enable a new data acquisition scheme for …

    gatech Repository record for Novel methods for iterative reconstruction and noise estimation in CT imaging (opens in a new tab)

  10. A Model Based Iterative Reconstruction Approach to Tunable Diode Laser Absorption Tomography

    … problem. In this thesis, we study the problem of reconstruction of TDLAT measurements into images representing 2D flow fields. We first propose a novel model-based iterative reconstruction (MBIR) framework for TDLAT imaging. To do this, we formulate a nonlinear measurement model for TDLAT that …

    purdue-thes Repository record for A Model Based Iterative Reconstruction Approach to Tunable Diode Laser Absorption Tomography (opens in a new tab)

  11. Modeling and Development of Iterative Reconstruction Algorithms in Emerging X-ray Imaging Technologies

    … radiation doses associated with use of analytic reconstruction methods in DPCT, we analyze the numerical and statistical properties of two classes of discrete imaging models that form the basis for iterative image reconstruction. Secondly, to improve image quality in grating-based phase-contrast …

    wustl Repository record for Modeling and Development of Iterative Reconstruction Algorithms in Emerging X-ray Imaging Technologies (opens in a new tab)

  12. Iterative reconstruction of three-dimensional model of human genome from chromosomal contact data

    [ACCESS RESTRICTED TO THE UNIVERSITY OF MISSOURI AT AUTHOR'S REQUEST.] 3D genome structures are important because they help us understand spatial gene regulation, transcription efficiency, genome interpretation, function implication (ENCODE), disease diagnosis, treatments and drug design. Recent …

    missouri Repository record for Iterative reconstruction of three-dimensional model of human genome from chromosomal contact data (opens in a new tab)

  13. Model-Based Iterative Reconstruction in Cone-Beam Computed Tomography: Advanced Models of Imaging Physics and Prior Information

    … in image quality and dose reduction. Model-based iterative reconstruction (MBIR) attempts to make more efficient use of the measurement data by incorporating a forward model of physical detection processes. Moreover, MBIR allows incorporation of various forms of prior information into image …

    jhu Repository record for Model-Based Iterative Reconstruction in Cone-Beam Computed Tomography: Advanced Models of Imaging Physics and Prior Information (opens in a new tab)

  14. Advanced Statistical Modeling for Model-Based Iterative Reconstruction for Single-Energy and Dual-Energy X-Ray CT

    Model-based iterative reconstruction (MBIR) has been increasingly broadly applied as an improvement over traditional, analytical image reconstruction methods in X-ray CT, primarily due to its significant advantage in drastic dose reduction without diagnostic loss. Early success of the method in …

    purdue-thes Repository record for Advanced Statistical Modeling for Model-Based Iterative Reconstruction for Single-Energy and Dual-Energy X-Ray CT (opens in a new tab)

  15. Iterative reconstruction as a novel method of radiation dose reduction at computed tomography in patients with Crohn's disease

    … limitation with conventional CT raw data reconstruction was the inherent coupling of administered radiation dose with observed image noise – the lower the radiation dose, the noisier the image. The renaissance, rediscovery and refinement of iterative reconstruction removes this limitation …

    cork Repository record for Iterative reconstruction as a novel method of radiation dose reduction at computed tomography in patients with Crohn's disease (opens in a new tab)

Page 1 of 9