Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 63 for “"Joint Rotation"”

  1. Hip joint rotation range of movement : improvement through stretching and an investigation of inter-tester reliability and agreement of the evaluative measurement method

    Full hip joint rotation is necessary for joint health and restriction is associated with pathology. Joint soft-tissue stretching is advocated, but there is no evidence to support this for improving hip joint rotation. Rotation measurement is fundamental to examination, diagnosis, determining …

    lancaster Repository record for Hip joint rotation range of movement : improvement through stretching and an investigation of inter-tester reliability and agreement of the evaluative measurement method (opens in a new tab)

  2. Experimental Study on the Longitudinal Strain Behavior of Polymer Pipe Liners Crossing Joints in Reinforced Concrete Pipes under Surface Loading

    … concrete pipes (RCPs) with bell-and-spigot joints. As these pipelines age, trenchless rehabilitation methods such as Cured-in-Place Pipe (CIPP) and Spray-in-Place Pipe (SIPP) liners are increasingly adopted as cost-effective and minimally disruptive alternatives to full replacement. While …

    queens Repository record for Experimental Study on the Longitudinal Strain Behavior of Polymer Pipe Liners Crossing Joints in Reinforced Concrete Pipes under Surface Loading (opens in a new tab)

  3. The Effects of Orthopaedic Surgery and Dorsal Rhizotomy on Selected Gait Characteristics of Cerebral Palsy Children

    … This included sagittal plane hip, knee and ankle joint rotation angles at initial contact, midstance and foot off; sagittal plane joint excursion at the hip, knee and anlde; average stride length; velocity; single limb support; and foot progression angle at initial contact. Postoperative changes …

    odu Repository record for The Effects of Orthopaedic Surgery and Dorsal Rhizotomy on Selected Gait Characteristics of Cerebral Palsy Children (opens in a new tab)

  4. Bending response of laser-welded web-core sandwich plates

    … calculations based on actual 3D topology. The rotation stiffness of the laser stake welded T-joint between the web and face plate is derived experimentally. This is considered to be important since the rotation stiffness affects the shear stiffness in the opposite direction to that of the web …

    aalto Repository record for Bending response of laser-welded web-core sandwich plates (opens in a new tab)

  5. Muscle responses to stretching and developing effective interventions in children with cerebral palsy

    Hyper-resistance at the joint is one of the most common symptoms in children with cerebral palsy (CP). There are both neural and non-neural factors contributing to the observed joint hyper-resistance. Non-neural alterations to the musculoskeletal system such as a reduced muscle length, increased …

    liverpool-jm Repository record for Muscle responses to stretching and developing effective interventions in children with cerebral palsy (opens in a new tab)

  6. The effects of stretching rate on plantar flexor maximum range of motion and resistance to stretch

    Maximal joint range of motion (max-ROM) and resistance to tissue elongation (components of ‘flexibility’) are important physical attributes influencing performances in athletic tasks and activities of daily living. Max-ROM tests are typically performed by rotating a joint using systems such as …

    edithcowan Repository record for The effects of stretching rate on plantar flexor maximum range of motion and resistance to stretch (opens in a new tab)

  7. Moment-rotation characteristics of semi-rigid high tensile bolted connections – II.

    … steel beams and columns to assume that the joints are free to rotate, unless they are especially designed as "fixed" joints, in which case it is assumed rotation is completely prevented. In actual fact, however, the joints are semi-rigid. Some rotation does take place, but this rotation is …

    mcgill Repository record for Moment-rotation characteristics of semi-rigid high tensile bolted connections – II. (opens in a new tab)

  8. Fatigue properties of dissimilar metal laser welded lap joints.

    … and dissimilar metal laser welded butt and lap joints, with the majority of the investigation concentrating on the fatigue properties of dissimilar metal laser welded lap joints. The problems encountered when laser welding zinc-coated steel are addressed and overcome with regard to dissimilar …

    sheffield-hallam Repository record for Fatigue properties of dissimilar metal laser welded lap joints. (opens in a new tab)

  9. Biomechanical response of the ankle to excessive external rotation

    … of eversion, dorsiflexion, and external rotation are often implicated in medial and high ankle sprains, the exact mechanisms are still unclear. Additionally, although studies have investigated the effect of shoe-surface interface on injury risk, few researchers have examined the effect of …

    msu Repository record for Biomechanical response of the ankle to excessive external rotation (opens in a new tab)

  10. Using biomechanical constraints to improve video-based motion capture

    … the human body model, such as limits on the rotational joints. This being an almost unexplored research subject, our efforts were mainly directed at determining a new method for measuring, representing and applying such joint limits. To the present day, the few existing range of motion …

    epfl Repository record for Using biomechanical constraints to improve video-based motion capture (opens in a new tab)

  11. MECHANICAL ANALYSIS OF HUMAN LUMBAR FACET JOINT AFTER ARTIFICIAL DISC REPLACEMENT (ADR) USING PRODISC II

    … will restore the intact mechanics of the spinal joints at both the index (L4L5) and adjacent level (L3L4). 6 cadaveric lumbar spines (L2-S1) were mounted onto MTS 858 Spine Tester with a follower preload system of 280 N, pressure sensors inserted into the facet joints and their motion captured …

    nus Repository record for MECHANICAL ANALYSIS OF HUMAN LUMBAR FACET JOINT AFTER ARTIFICIAL DISC REPLACEMENT (ADR) USING PRODISC II (opens in a new tab)

  12. Foot Behavior during Walking based on Foot Kinetics and Kinematics

    … foot motion features are extracted, including joint rotation angles between sub-defined foot segments, and some proposed functional angles for describing the whole foot physical features of walking. Extracted foot motion features are applied to designed different walking conditions for their …

    nus Repository record for Foot Behavior during Walking based on Foot Kinetics and Kinematics (opens in a new tab)

  13. Seismic response of precast concrete wall panels

    … separated into three separate component parts, joint rotation, wall panel deformations and horizontal wall panel sliding, to compare and evaluate the seismic performance of the wall panels.

    mcgill Repository record for Seismic response of precast concrete wall panels (opens in a new tab)

  14. Effects of the glenohumeral joint center on the role of the middle deltoid : implications for reverse total shoulder arthroplasty.

    … medializes the center of glenohumeral joint rotation, lending larger moment arms to undamaged muscles like the deltoid. The aim of this thesis was to create and use a computational model of the glenohumeral joint with an adjustable joint center to investigate and quantify the role of …

    baylor Repository record for Effects of the glenohumeral joint center on the role of the middle deltoid : implications for reverse total shoulder arthroplasty. (opens in a new tab)

  15. Design and Validation of a Smart Brace; Wearable Technology for Carpal Tunnel Syndrome

    … flexion/extension and radial/ulnar deviation joint rotation centres. Thirteen subjects performed activities of daily living while wearing the brace and kinematic data were also collected with VICON motion capture. Range of motion, mean angle, peak and mean velocity, and mean acceleration were …

    guelph Repository record for Design and Validation of a Smart Brace; Wearable Technology for Carpal Tunnel Syndrome (opens in a new tab)

  16. Development and Testing of a Polycentric Knee Joint for Powered Walking Assist Exoskeletons

    … to develop a kinematically compatible knee joint suitable for exoskeletons. The proposed knee design can be adapted to accommodate an offset and optimize force delivery. This is achieved by ensuring that the mechanical and biological joint rotation axes are aligned and that the moment arm …

    ottawa-retro Repository record for Development and Testing of a Polycentric Knee Joint for Powered Walking Assist Exoskeletons (opens in a new tab)

  17. Instantaneous center of rotation shifts in symptomatic anterior cruciate ligament deficient knee joints

    … Displacement variables were extrapolated from joint rotation profiles generated from these coordinates. Abnormal displacement migrations of the IC parameter were demonstrated to occur in extension. Migration displacements evaluated between 30$ sp circ$ and 0$ sp circ$ shifted anteriorly 5.07 $ …

    mcgill Repository record for Instantaneous center of rotation shifts in symptomatic anterior cruciate ligament deficient knee joints (opens in a new tab)

  18. Model-Based Design and Development of an Offboard Actuation System for Lower-Limb Biomechatronic Devices

    … actuators and versatile control systems to apply joint torques to assistive devices through flexible transmission tethers. This setup allows researchers to rapidly prototype assistive device behaviors and control laws without committing to a specific wearable device embodiment. The goal of this …

    washington Repository record for Model-Based Design and Development of an Offboard Actuation System for Lower-Limb Biomechatronic Devices (opens in a new tab)

Page 1 of 4