Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 38 for “"Joint prosthesis"”

  1. Elbow joint prosthesis design : biomechanical aspects

    … biomechanical analysis of elbow joint function is presented. Eating, dressing, pulling a heavy object and assisted standing from the seated position were investigated for healthy males in the age group 21 -25 years. Three cine cameras recorded the motion of specially designed …

    strathclyde Repository record for Elbow joint prosthesis design : biomechanical aspects (opens in a new tab)

  2. Hypothetical design for an ankle-subtalar joint prosthesis

    … of hindfoot arthritis and the development of a prosthesis that may possibly provide a solution for both ankle and subtalar arthritis.

    nanyang Repository record for Hypothetical design for an ankle-subtalar joint prosthesis (opens in a new tab)

  3. Functionalized coatings by Cold Spray for joint prosthesis

    … and Calcium Phosphate (CP) coatings by CS for joint prosthesis application. An exhaustive development of coating parameter optimization has been developed and the different deposition mechanisms for each feedstock powder were analyzed as well. The mechanical and biological properties of the …

    barcelona Repository record for Functionalized coatings by Cold Spray for joint prosthesis (opens in a new tab)

  4. The Design of a Subtalar Joint Prosthesis Wear Testing Mechanism

    The subtalar joint forms part of the triple joint complex in the foot and is primarily responsible for inversion and eversion of the hind foot and ankle. Injury to the subtalar joint typically arises as a result of primary osteoarthritis or sequelae of injury. When non-invasive treatments are no …

    alberta Repository record for The Design of a Subtalar Joint Prosthesis Wear Testing Mechanism (opens in a new tab)

  5. Investigating the functionalisation of poly-ether-ether-ketone surfaces through the application of surface texturing for friction and wear control within all polymeric joint prosthesis

    This thesis investigates the application of surface textures applied to an un-filled poly-ether-ether-ketone (PEEK) surface via laser ablation for the purpose of friction and wear control. Surface functionalisation was demonstrated by the manipulation of surface characteristics via texturing. …

    birmingham Repository record for Investigating the functionalisation of poly-ether-ether-ketone surfaces through the application of surface texturing for friction and wear control within all polymeric joint prosthesis (opens in a new tab)

  6. A finger function simulator and surface replacement prosthesis for the metacarpophalangeal joint

    Joint replacement surgery in the treatment of arthritic disease is now commonplace and on the whole very successful. Research into the design and development of prostheses has made major advances since the 1940s resulting in complex devices for almost all articulating joints of the body. In this …

    durham Repository record for A finger function simulator and surface replacement prosthesis for the metacarpophalangeal joint (opens in a new tab)

  7. Physical activity as a tool to improve the quality of life for individuals with hip or knee osteoarthritis

    … (OA), effectively alleviating pain, enhancing joint mobility and quality of life (QoL). Maintaining an active lifestyle and regular physical activity (PA) is crucial for these patients, as it can increase bone density and stability of joint prosthesis. This thesis aims to: (1) systematically …

    bologna Repository record for Physical activity as a tool to improve the quality of life for individuals with hip or knee osteoarthritis (opens in a new tab) Embargoed

  8. Characterization of the Rank Ligand Positive Giant Cell Found in the Interfacial Membrane

    … osteolysis is a major complication to total joint arthroplasty requiring several thousand people a year to have to undergo revisions of their joint prosthesis. The formation of the interfacial membrane has been associated with aseptic osteolysis leading to the failure of all types of total …

    vcu Repository record for Characterization of the Rank Ligand Positive Giant Cell Found in the Interfacial Membrane (opens in a new tab)

  9. MRI Registration for Human Hip Kinematics

    Measurement of joint kinematics can provide knowledge to help improve joint prosthesis design, as well as identify joint motion patterns that may lead to joint degeneration or injury. More investigation into how the hip translates in live human subjects during high amplitude motions is needed. This …

    queens Repository record for MRI Registration for Human Hip Kinematics (opens in a new tab)

  10. Hip joint forces : hip joint forces of 40 to 60 year old normal and total hip replacement subjects during walking and stair, ramp and camber negociation

    To design and test hip joint prosthesis it is essential to know the magnitude and character of forces that may be applied to them in-vivo. For this thesis the hip joint forces of 40 to 60 year old subjects (five male and six female normal subjects and five male hip replacement) were studied. To …

    strathclyde Repository record for Hip joint forces : hip joint forces of 40 to 60 year old normal and total hip replacement subjects during walking and stair, ramp and camber negociation (opens in a new tab)

  11. Development of an Optimum Artificial Wrist Joint

    Wrist joint prostheses have developed from simple silicone joint spacers to the current state of the art where design philosophy now follows that of large joint replacement. A variety of shortcomings identified in existing designsthrough their clinical use led to the development of a new wrist …

    east-london Repository record for Development of an Optimum Artificial Wrist Joint (opens in a new tab)

  12. Reconstruction of distal femoral fractures with fixed-angled or polyaxial technology; a prospective randomised controlled trial.

    … confounding co-morbidities, a high percentage of joint prosthesis and osteoporosis, which increase the technical demands on the surgeon and the selected implant. Locking osteosynthesis devices have been shown to provide superior stability to axial loading compared with traditional, unlocked …

    whiterose Repository record for Reconstruction of distal femoral fractures with fixed-angled or polyaxial technology; a prospective randomised controlled trial. (opens in a new tab)

  13. Development of surface replacement prostheses for the proximal interphalangeal and metacarpo phalangeal joints

    … main aims of the project. A surface replacement prosthesis was previously designed at the University of Durham for the metacarpo-phalangeal joint (MCPJ). Tools were required to assess the joint prosthesis pre-operatively and postoperatively. The areas of assessment which the author was involved …

    durham Repository record for Development of surface replacement prostheses for the proximal interphalangeal and metacarpo phalangeal joints (opens in a new tab)

  14. Improving bone and implant surface integration

    Background and Aims: Cementless joint prosthesis has been a major module in joint replacement since 1980s. However, bone-implant aseptic loosening is still an important complication. This study was performed to assess the effects of implant surface fabrications and coatings on new bone growth on …

    unsw Repository record for Improving bone and implant surface integration (opens in a new tab)

  15. ASTM assessment of a novel shoulder prosthetic design: measurement of glenoid edge motion in three degrees of freedom

    … cause for failure of An anatomical shoulder joint prosthesis is loosening of the glenoid component, widely attributed to ‘rocking' of the component under eccentric edge loading. The American Society for Testing and Materials (ASTM) set out a standardised test to evaluate glenoid loosening, in …

    cape-town Repository record for ASTM assessment of a novel shoulder prosthetic design: measurement of glenoid edge motion in three degrees of freedom (opens in a new tab)

  16. Comparing pre and post-surgical self-efficacy behavior changes by introducing prehabilitation exercise.

    … cure for OA other than replacing the diseased joint with a joint prosthesis, total knee arthroplasty (TKA). Purpose: This study compared pre and post-surgical functional ability, exercise self efficacy and outcome expectations among total knee arthroplasty (TKA) patients who did and did not …

    louisville Repository record for Comparing pre and post-surgical self-efficacy behavior changes by introducing prehabilitation exercise. (opens in a new tab)

  17. Prosthetic joint infections, biomarkers and antibiotic stewardship

    … resistance.<br/><br/>A good example is joint replacement (Arthroplasty), the majority of which are successful. Not only do they provide pain relief, restore function and independence, but also improve the patients’ quality of life. Prosthetic (or periprosthetic) joint infection (PJI) or …

    soton Repository record for Prosthetic joint infections, biomarkers and antibiotic stewardship (opens in a new tab)

  18. Antibacterial properties of multifunctional coatings Ag-ZrCN for biomedical devices: a novel approach

    … and related health problems, knee and hip joint prosthesis are being widely used worldwide. However, failure of these invasive devices is still a concern in the medical field thus demanding the revision of the surgical procedure. Within the reasons of failure are wear fatigue and microbial …

    minho-thes Repository record for Antibacterial properties of multifunctional coatings Ag-ZrCN for biomedical devices: a novel approach (opens in a new tab)

Page 1 of 2