Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 17 of 17 for “"K-space trajectory"”

  1. Non-Cartesian Trajectory Design for Simultaneous Multislice

    … underexplored. This study proposes a 3D k-space trajectory which behaves like a spiral in the x-y plane while oscillating sinusoidally in the z-direction—hence the name Laterally Oscillating Trajectory for Undersampling Slices (LOTUS). LOTUS enables high slice acceleration and produces a …

    uwo Repository record for Non-Cartesian Trajectory Design for Simultaneous Multislice (opens in a new tab)

  2. Follow your label: simultanous 4D angiography and perfusion imaging by arterial spin labeling MRI

    … or a golden angle based non-Cartesian k-space trajectory to obtain high temporal resolution multi-time point data. These datasets were then used to improve the quantification of ASL signal and to obtain cerebral blood flow, arterial transit time and arterial blood volume maps. These …

    leiden Repository record for Follow your label: simultanous 4D angiography and perfusion imaging by arterial spin labeling MRI (opens in a new tab)

  3. A Pseudo Non-Cartesian Pulse Sequence For Hyperpolarized Xenon-129 Gas MRI of Rodent Lungs At Low Magnetic Field Strength

    … imaging sequence based on a pseudo-Cartesian k-space trajectory, known as Sectoral, is implemented at low magnetic field (0.07 T) for efficient use of the non-renewable magnetization of hyperpolarized 129Xe gas. A pilot study was performed to demonstrate the feasibility of ADC mapping using the …

    uwo Repository record for A Pseudo Non-Cartesian Pulse Sequence For Hyperpolarized Xenon-129 Gas MRI of Rodent Lungs At Low Magnetic Field Strength (opens in a new tab)

  4. Wave-CAIPI for Accelerated Dynamic MRI of the Thorax

    In summary, the wave-CAIPI k-space trajectory presents an efficient sampling strategy for accelerated MR acquisitions. Using wave-CAIPI in parallel imaging reconstructions leads to a reduced noise level in the reconstructed images, compared to the Cartesian standard trajectory. This effect could be …

    wurz-thes Repository record for Wave-CAIPI for Accelerated Dynamic MRI of the Thorax (opens in a new tab)

  5. Accelerated non-Cartesian cardiovascular MR Imaging at 3T and 7T

    … data acquisition, highly efficient spiral k-space trajectories were created. In addition, hybrid sampling patterns such as the twisting radial lines (TWIRL) k-space trajectory were studied. Imperfections of the dynamic gradient system of a MR scanner result in k-space sampling errors. …

    wurz-thes Repository record for Accelerated non-Cartesian cardiovascular MR Imaging at 3T and 7T (opens in a new tab)

  6. Rapid data acquisition and selective excitation in magnetic resonance imaging

    … enhancement pulses. A method for measuring the k-space trajectories of gradient waveforms was adopted, modified, validated and used to measure the k-space trajectories of gradient waveforms used for selective excitation and spiral image acquisition. Distortion was observed even when gradient …

    mcgill Repository record for Rapid data acquisition and selective excitation in magnetic resonance imaging (opens in a new tab)

  7. Application of center-out k-space trajectories to three-dimensional imaging of structure and blood transport in the human brain

    A novel non-invasive imaging method of unique k-space trajectory named “3D center-out EPI with cylindrical encoding” was developed and implemented for fast imaging of the human brain. The method based on a variant of 3D hybrid EPI combines advantages of the Cartesian and the radial encoding to …

    qucosa-diss Repository record for Application of center-out k-space trajectories to three-dimensional imaging of structure and blood transport in the human brain (opens in a new tab)

  8. Quantifying Lung Water Density with Ultrashort Echo Time Yarn-Ball MRI

    … a novel Yarn-Ball (YB) ultrashort TE (UTE) k-space trajectory along side an automated image processing approach. Efficiency optimized UTE-YB k-space trajectories were designed for breath-hold and free-breathing acquisitions. These provide full torso spatial coverage with minimal T1 and T2* …

    alberta Repository record for Quantifying Lung Water Density with Ultrashort Echo Time Yarn-Ball MRI (opens in a new tab)

  9. Measuring Dynamic Changes in Lung Water Density and Volume Following Supine Body Positioning Using Free-Breathing UTE MRI

    … low SNR, high signal variations across the image space due to B1 field inhomogeneity, artifacts caused by respiratory and cardiac motion, and a need to normalize signal units within the lung parenchyma to units of lung water content. Through these methods, lung water density (LWD) has been shown …

    alberta Repository record for Measuring Dynamic Changes in Lung Water Density and Volume Following Supine Body Positioning Using Free-Breathing UTE MRI (opens in a new tab)

  10. CONTINUOUS SAMPLING IN MAGNETIC RESONANCE IMAGING

    … are used to acquire spatial-frequency data (k-space) by using linear magnetic field gradients to encode a k-space trajectory. Common k-space trajectories including rectilinear typically limit sampling to periods of constant gradient amplitude resulting in uniformly-sampled data during the …

    ohiolink Repository record for CONTINUOUS SAMPLING IN MAGNETIC RESONANCE IMAGING (opens in a new tab)

  11. Fine-tuning of 3D spiral navigator trajectories for improved motion correction in magnetic resonance imaging using a novel simulation framework (SpiralTrack)

    … acquisition time is largely determined by its k-space trajectory, the path taken through the frequency-space MRI data is acquired in. Spiral trajectories are attractive as they efficiently utilize the MRI system's gradient hardware to maximize sampling coverage. In practice, spiral navigators …

    mcgill Repository record for Fine-tuning of 3D spiral navigator trajectories for improved motion correction in magnetic resonance imaging using a novel simulation framework (SpiralTrack) (opens in a new tab)

  12. Optimisation of vessel-selective magnetic resonance perfusion imaging and angiography

    … in approximately one minute. A radial k-space trajectory was found to offer the best vessel definition and SNR. Three-dimensional (3D) angiograms provide the most detailed view of the cerebral vasculature for use in diagnosis and treatment of cerebrovascular disease. A 3D radial readout …

    oxford Repository record for Optimisation of vessel-selective magnetic resonance perfusion imaging and angiography (opens in a new tab)

  13. Investigation and development of MRI-based multi-compartment myelin imaging methods

    … study using a novel, locally developed k-space trajectory has also shown potential for our technique to form a complete, motion corrected neuroimaging pipeline.

    kings Repository record for Investigation and development of MRI-based multi-compartment myelin imaging methods (opens in a new tab)

  14. 4D ultra-short TE (UTE) phase-contrast MRI for assessing stenotic flow and hemodynamics.

    … blood velocity using a UTE center-out radial k-space trajectory with short TE time compared to standard PC MRI sequences. 3D UTE characterizes flow in one direction in a 3D volume, resulting in a single component of the flow velocities. In order to obtain a comprehensive flow assessment in three …

    louisville Repository record for 4D ultra-short TE (UTE) phase-contrast MRI for assessing stenotic flow and hemodynamics. (opens in a new tab)

  15. Development of rapid high-resolution MR spectroscopic imaging in the human brain

    … multiple repetitions in most commonly used k-space trajectories do not share common points that can be used to estimate and correct for these offsets. This project involved the development, implementation and optimisation of a new rapid high-resolution 2D FID-MRSI pulse sequence using a …

    mcgill Repository record for Development of rapid high-resolution MR spectroscopic imaging in the human brain (opens in a new tab)

  16. Minimizing the Adverse Effects of Electric Fields in Magnetic Resonance Imaging using Optimized Gradient Encoding and Peripheral Nerve Models

    … available performance. The skeleton of the trajectory is defined by a set of k-space control points. The method optimizes gradient waveforms that traverse the k-space control points in the minimum possible amount of time. By using an analytic representation of the gradients (piece-wise …

    heid-diss Repository record for Minimizing the Adverse Effects of Electric Fields in Magnetic Resonance Imaging using Optimized Gradient Encoding and Peripheral Nerve Models (opens in a new tab)

  17. Advanced acquisition and reconstruction methods for MRI of tissues with short T2 or T2*

    … content of the deep brain nuclei.<br>Radial k-space encoding is also used in motion correction and interventional MRI, because it is less sensitive to motion. However, in radial encoding outer k-space regions are highly undersampled compared to the inner k-space. In this thesis, to improve the …

    freiburg-diss Repository record for Advanced acquisition and reconstruction methods for MRI of tissues with short T2 or T2* (opens in a new tab)