Results 1 to 16 of 16 for “"KT-1000 arthrometer"”
-
Evaluation of patients with an anterior cruciate ligament rupture, before and after reconstruction, with special emphasis on the use of the KT-1000 arthrometer
… on thesagittal knee laxity as measured with the KT-1000 arthrometer.The patients were operated on using bone-patellar tendon-bone autografts and rehabilitatedaccording to an individual training programme based on standardised accelerated guidelines.The post-operative outcome two years after …
-
Femorale und tibiale Transplantatfixation der vorderen Kreuzbandplastik mit der neuartigen bioresorbierbaren Interferenzschraube Milagro®
… In unserer Klinik erfolgte von Juni 2005 bis Oktober 2006 bei 35 Patienten die Transplantatfixation mittels Milagro®-Schrauben in arhroskopischer Technik. Bei 15 Patienten wurde als Transplantat die Semitendinosussehne alleine und bei 20 Patienten die Semitendinosus- in Kombination mit der …
-
Ein Vergleich zweier vorderer Kreuzbandersatzplastiken mit Patellarsehne vs. Semitendinosus- und Gracilissehnen im 5 Jahresverlauf – eine prospektive, randomisierte Studie
… es, die Resultate nach arthroskopischer Rekonstruktion des vorderen Kreuzbandes (ACL)unter Verwendung der zentral-dritten Knochen-Patellarsehne-Knochen (LP) Autografts und der dreifachen/vierfachen Semitendinosus (ST) Autografts zu vergleichen. Hypothese: In der untersuchten Zeitdauer bietet die …
-
Συγκριτική μελέτη συνδεσμοπλαστικής προσθίου χιαστού συνδέσμου με επιγονατιδικό τένοντα ή τετραπλό τενόντιο μόσχευμα ισχνού-ημιτενοντώδη
… score, clinical and subjective tests and the KT-1000 arthrometer. Early complains of anterior knee pain in the patellar tendon group, did not affect the result at 2 years. Conclusion: Both hamstring and patellar tendon grafts provided satisfactory subjective outcomes and objective stability at …
-
Εμβιομηχανική ανάλυση της κίνησης του γόνατος πριν και μετά από ρήξη και αποκατάσταση του προσθίου χιαστού συνδέσμου
… was regained, while measurements with the KT-1000 arthrometer showed that their anterior tibial translation was restored. However, both ACL reconstructed groups demonstrated significantly increased tibial rotation. Conclusions: Excessive tibial rotation has been documented in ACL …
-
Ein 10-Jahres-Vergleich zweier Rekonstruktionsverfahren nach ACL-Ruptur Semitendinosussehnen- vs. Patellarsehnentransplantat : eine prospektive randomisierte Studie
Vergleich zweier Verfahren zur Rekonstruktion des vorderen Kreuzbandes: Ligamentum patellea vs. Semitendinosussehnentransplantat. 10-jahres Ergebnisse einer prospektiven, randomisierten klinischen Studie. Verfahren: Diese Studie vergleicht die Ergebnisse einer 10-Jahres Nachuntersuchung nach …
-
Μετεγχειρητική πορεία συνδεσμοταστικής προσθίου χιαστού συνδέσμου με χρήση συνθετικών μοσχευμάτων (LARS και ABC)
… as well as laxity measurements obtained using a KT-1000 arthrometer were recorded for all intact grafts, and a Mann-Whitney U test was used for comparison reasons.Results: The rupture rates for LARS and ABC grafts were 31% and 42%, respectively (CI 95%). For intact grafts, the mean Lysholm score …
-
Κλινική και εργομετρική αξιολόγηση της επιστροφής στην άθληση μετά από αποκατάσταση ρήξεως πρόσθιου χιαστού συνδέσμου σε ερασιτέχνες αθλητές
… to the healthy contralateral knee by the KT-1000 arthrometer. Results : Patients in the two groups did not differ regarding demographics, and pre-injury functionality status. Significantly more patients in the HT group (n=6) compared to the BPTB group (n=1) experienced ACL re-rupture and …
-
Έλεγχος επαναγγείωσης μοσχευμάτων οπίσθιων μηριαίων και τετρακεφάλου μετά την συνδεσμοπλαστική πρόσθιου χιαστού συνδέσμου: απεικόνιση με μαγνητική τομογραφία και σύγκριση μεταξύ τους
… score, Biodex isokinetic test, Lysholm score and KT-1000 arthrometer displacement. The enhancement index (EI) was calculated in three specific sites of each graft and comparisons for every time interval were performed. These sections are: the intra-articular (section - 1), the intraosseous - tibia …
-
Anterior Cruciate Ligament Reconstruction; Randomized Trials, Register Studies and Experimental Analysis of Knee Laxity
… over time in both groups, as measured with the KT-1000 arthrometer. In Study III, a retrospective study of 244 patients, the results after ACL reconstruction using HS autografts were compared in male versus female patients. At the 2-year follow-up, there were no significant differences between …
-
Ανατομική ανακατασκευή του πρόσθιου χιαστού συνδέσμου του γόνατος: προοπτική κλινική και εμβιομηχανική μελέτη
… of anterior tibial translation with the KT-1000 arthrometer, the TR measurement during high demanding pivoting tasks using 3 dimensional optoelectronic motion analysis system, knee joint function scores and assessment of the activity level of the patient. Magnetic resonance imaging was …
-
Langzeitergebnisse operativ versorgter traumatischer Kniegelenksluxationen
… in der Poplitealregion, erhebliche Weichteildefekte bis hin zum Kompartmentsyndrom und Dehnungsschäden exponierter Nerven wie des Nervus peroneus communis verschlechtern die Prognose. Deshalb müssen etablierte Therapiekonzepte unbedingt eingehalten werden. Dabei ist eine frühzeitige, situativ …
-
„Sport und Alltagsfähigkeit nach vorderer Kreuzbandplastik mittels den Semitendinosus- und Gracilissehnen versus der Patellarsehne“
… Jahren unterziehen sich einer VKB-Rekonstruktion mittels der Patellarsehne. 31 weitere Patienten, 16 Frauen und 15 Männer, mit einem Durchschnittsalter von 34,23 (16-55) Jahren werden mittels der Hamstringssehnen operativ versorgt. Beide Operationstechniken werden in einer neuartigen, …
-
Kinematics and laxity in the knee, before and after Anterior Cruciate Ligament reconstruction. Evaluation using dynamic and static radiostereometric analysis
… an ACL reconstruction, which does not use the KT-1000 as an evaluation instrument to assess objective outcome. The question of whether the results of KT-1000 measurements are sufficiently accurate and the extent to which they are clinically relevant still remains. Previous studies have shown …
-
Generalized Joint Hypermobility and Specific Knee Laxity: Aspects of influence on the Anterior Cruciate Ligament Injured Knee
… to anterior tibial translation (ATT), using the KT-1000 arthrometer, and in relation to the frequency of concomitant intra-articular injuries in the ACL-injured knee. The ATT was examined six months postoperatively. The study identified an association between contralateral knee hyperextension and …
-
Primärer versus Revisionsersatz des vorderen Kreuzbandes mit autologen Hamstringsehnen
Ziel dieser Studie war es dem aktuellen Mangel an signifikanten Studien mit zu geringen Fallzahlen, dem Fehlen von Kontrollgruppen und dem retrospektiven Studiendesign der wenigen Untersuchungen zum Thema Revisionschirurgie entgegenzuwirken. Anhand unseres eigenen Patientenkollektives untersuchten …