  1. Clinical applications of the kT-points method to homogenise spin excitation in 3T MRI

    … sur un grand champ de vue. La méthode des points kT, développée à NeuroSpin pour l’IRM cérébrale à ultra-haut champ (7T) utilise une alternance d’impulsions RF rectangulaires et de gradients de champ statique pour moduler à dessein l’aimantation des spins et ainsi homogénéiser l’excitation …

    star-france Repository record for Clinical applications of the kT-points method to homogenise spin excitation in 3T MRI (opens in a new tab)

  2. Parallel transmission for magnetic resonance imaging of the human brain at ultra high field : specific absorption rate control & flip-angle homogenization

    … et relativement peu énergétiques, appelées « kT-points », est d'abord démontré dans l’approximation des petits angles de bascule de l’aimantation. Pour cibler un éventail d’applications plus large, la conception de type kT-points est ensuite généralisée en englobant les excitations à grand …

    star-france Repository record for Parallel transmission for magnetic resonance imaging of the human brain at ultra high field : specific absorption rate control & flip-angle homogenization (opens in a new tab)

  3. B1+-mapping and B1+ inhomogeneity correction at high field

    … magnetization profile. It was already known that kT-point pulses designed in the small tip angle (STA) approximation provided substantial B1+ inhomogeneity correction. In this thesis, a methodology expressing the Bloch equations in a linear form was developed for the design of kT-point pulses …

    epfl Repository record for B1+-mapping and B1+ inhomogeneity correction at high field (opens in a new tab)

  4. Non-selective Refocusing Pulse Design in Parallel Transmission for Magnetic Resonance Imaging of the Human Brain at Ultra High Field

    … avec navigation dans l’espace de Fourier, les kT-points, et un algorithme d’optimisation, appelé Gradient Ascent Pulse Engineering (GRAPE), utilisant le contrôle optimal. Cette conception est rapide grâce à des calculs analytiques plus directs que des méthodes de différences finies. La prise en …

    star-france Repository record for Non-selective Refocusing Pulse Design in Parallel Transmission for Magnetic Resonance Imaging of the Human Brain at Ultra High Field (opens in a new tab)