Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 9 of 9 for “"Kastle-Meyer"”
-
Comparison of the sensitivity of presumptive blood tests Kastle-Meyer, O-Tolidine and Luminol on six fabric substrates
… of hemoglobin. Tests such as phenolphthalein (Kastle-Meyer), Ortho-Tolidine (O-Tol), and Luminol utilize this method. The sensitivity of presumptive blood tests was evaluated using a series of diluted bloodstains on six fabrics: fleece, felt, linen, denim, flannel, and terrycloth. In addition …
-
Effects of chemical blood enhancement methods on downstream biological testing
… bloodstains were subsequently tested with the Kastle-Meyer and ortho-tolidine presumptive catalytic color tests as well as the ABAcard® HemaTrace® confirmatory immunoassay card. This was true for stains on both porous and non-porous substrates regardless of bloodstain size or time between …
-
Química forense: análise de manchas de sangue em cena de crime
… presença de sangue são os testes preliminares, Kastle – Meyer, Teste de Adler e Luminol, e confirmatórios, Teste de Teichmann e Takayama, além de padrões de mancha de sangue encontrados no local da ocorrência. O estudo de caso auxilia a compreensão da análise realizada pelo perito por apresentar …
-
Comparação de resultados entre Testes Presuntivos/Indicadores de Sangue, em contexto de Local do Crime
… nomeadamente, luminol, fluoresceína, Kastle-Meyer, leucomalachite green e tetrabase, em situações limite, que podem ser encontradas em múltiplos locais do crime. Assim, inicialmente, foi estudada a sensibilidade dos vários testes presuntivos, em dois substratos distintos, avaliando a …
-
Evaluation of wet-vacuum technique versus traditional methods for collection of biological crime scene samples
… presence of blood. Testing was performed with Kastle-Meyer (phenolphthalein) reagents. Each sample was photographed under consistent conditions in order to determine signal intensity. It was shown that the wet-vacuuming technique is able to recover sufficient amounts of blood for presumptive …
-
Forensic blood testing after long-term exposure to chemical interferents
… of false negatives for both presumptive (Kastle-Meyer and Orthotolidine) and confirmatory (RSID™ and HemaTrace®) tests for blood. Detailed preliminary visual inspections were also performed. Upon inspection, many samples contained less than a 1:10 concentration of blood which was difficult …
-
False negative results for blood tested in the presence of chemical interferents
… their effects on presumptive blood tests such as Kastle Meyer (KM) and Orthotolidine (O-tol) reagents and confirmatory tests such as HemaTrace® and Rapid Stain Identification (RSID™) Blood. Additional experiments explored the effects on downstream DNA analysis. In the first part of the study, …
-
Characteristics of bloodstains on waterproof fabrics
… were overwhelmingly detected by the presumptive Kastle-Meyer blood test, with only a single instance of a negative result. In contrast, test results were more evenly split among the spatter stains on waterproof fabrics and were less likely to produce positive test results. Positive test results …
-
Effects of decomposition on the recoverability of biological fluid evidence
… stains changed from red-brown to green-yellow. Kastle-Meyer (KM) testing was positive for all samples and ABAcard® HemaTrace® testing was positive for 14 of 22 samples, with the negative results occurring during days 12 - 21. Two stains that were negative at 10 minutes turned positive shortly …