Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 12 of 12 for “"Kerfs"”.

  1. Design of high frequency ultrasonic array transducers for medical imaging

    … of array geometry is developed including the kerfs influence which is usually neglected in the design of high frequency arrays. The improved imaging performance is found by this optimized design. More interestingly, the conventional annular array with element having the same surface area has a …

    soton Download PDF for Design of high frequency ultrasonic array transducers for medical imaging (opens in a new tab)

  2. The Identification and Classification of Sharp Force Trauma On Bone Using Low Power Microscopy

    … system for the identification of knife cuts (kerfs) in bone. The system was devised, to record accurate and reliable information about cut marks and the criteria were tested for association with the knives that created them. Optical Microscopy was used to examine knife cuts on fleshed porcine …

    cent-lancashire Download PDF for The Identification and Classification of Sharp Force Trauma On Bone Using Low Power Microscopy (opens in a new tab)

  3. The effects of thermal alteration on saw mark сharacteristics

    … superficial false start scratches, false start kerfs, and completely sectioned cuts with breakaway spurs/notches. The long bones were burned at the Boston University School of Medicine using a muffle furnace, at differing temperatures and at differing time increments. The author hypothesized …

    bu Repository record for The effects of thermal alteration on saw mark сharacteristics (opens in a new tab)

  4. Reciprocating saws as tools of dismemberment: analysis of class characteristics and practical utility

    … or both materials. The resulting false start kerfs and complete kerfs on the remains were then examined macroscopically and microscopically. The present study utilized both qualitative and quantitative analysis to examine kerf features that characterize reciprocating saws. The presentation of …

    bu Repository record for Reciprocating saws as tools of dismemberment: analysis of class characteristics and practical utility (opens in a new tab)

  5. An examination of electric chainsaw class characteristics in bone and the effects of thermal alteration

    … Three electric chainsaws were used to create kerfs on 52 semi-fleshed white-tailed deer (Odocoileus virginianus) bones, which were used as an approximation for human remains. Bones were divided into 6 samples that were color coded to facilitate a blind study. The electric chainsaws used were: …

    bu Repository record for An examination of electric chainsaw class characteristics in bone and the effects of thermal alteration (opens in a new tab)

  6. Cut it out: a novel, quantifiable approach to kerf mark analysis using 3D confocal microscopy and machine learning

    … Significantly, our results differentiate between kerfs produced by serrated blades, non-serrated blades, and partially serrated blades, not only allowing for more specific blade identifications but also producing a quantifiable and replicable method meeting the Daubert criteria.

    colostate Repository record for Cut it out: a novel, quantifiable approach to kerf mark analysis using 3D confocal microscopy and machine learning (opens in a new tab)

  7. Examination of sharp force trauma of the Winchester Site remains

    … is seen through the 349 transverse complete kerfs located on the postcranial remains. There are 125 sternal segments and 133 rib segments with evidence of sharp force trauma, potentially from thoracotomy. The postmortem alteration within the faunal assemblage can be attributed to butchery on …

    bu Repository record for Examination of sharp force trauma of the Winchester Site remains (opens in a new tab)

  8. Correlation between saw blade width and kerf width

    … saws. A total of 500 false start kerfs (FSKs) were measured using digital calipers. Two experiments were performed, with the first test examining the kerf widths of false starts produced on specimens that were restrained using clamps, while the second test analyzed the kerf widths …

    bu Repository record for Correlation between saw blade width and kerf width (opens in a new tab)

  9. Analytical and experimental studies in laser cutting

    … However the line beam cuts exhibited wider kerfs and rougher surfaces, especially at the bottom of the cuts, compared to the circular beam. The line beam could be beneficial in applications with high power lasers where plasma formation has to be minimized. Numerical models of laser cutting …

    iastate Repository record for Analytical and experimental studies in laser cutting (opens in a new tab)

  10. Models for Pedestrian Trajectory Prediction and Navigation in Dynamic Environments

    Robots are no longer constrained to cages in factories and are increasingly taking on roles alongside humans. Before robots can accomplish their tasks in these dynamic environments, they must be able to navigate while avoiding collisions with pedestrians or other robots. Humans are able to move …

    calpoly Repository record for Models for Pedestrian Trajectory Prediction and Navigation in Dynamic Environments (opens in a new tab)

  11. Optimisation of process parameters of high power CO2 Laser cutting for advanced materials

    … kerf width, lower kerf width, ratio between two kerfs, heat affected zone (HAZ), roughness of the cut section and operating cost. Materials, commonly used in industry, in sheet form with different thicknesses, have been investigated namely: medical grade austenitic stainless steel AISI316L, …

    dcu Download PDF for Optimisation of process parameters of high power CO2 Laser cutting for advanced materials (opens in a new tab)

  12. Examination of hacking and blunt force skeletal trauma

    … the blade angles and the visibility of these kerfs, with the visibility decreasing around the 60 blade angle (p-value = 0.003). With regards to the fracture patterns, there was a correlation between the appearance of transverse fractures, with a decrease in more blunt blade angles (p-value = …

    bu Repository record for Examination of hacking and blunt force skeletal trauma (opens in a new tab)