Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 39 for “"Kilovoltage"”.

  1. Kilovoltage Intensity Modulated Radiotherapy

    Contrast enhanced kilovoltage radiotherapy could be a significant improvement over the standard of care in glioblastoma multiforme, but its potential benefit has been hindered by fears of insufficient dose falloff, high skin and skull dose, contrast delivery concerns, and high cost. This …

    wayne-thes Repository record for Kilovoltage Intensity Modulated Radiotherapy (opens in a new tab)

  2. Optimizing Kilovoltage Cone-Beam Computed Tomography for Image-Guided Radiation Therapy

    Kilovoltage cone-beam computed tomography (kV CBCT) has important applications in image guided radiation therapy (IGRT). In its current state, CBCT is suboptimal for these applications due to its considerable radiation dose, poor soft-tissue contrast and inaccurate Hounsfield Units as a result of …

    utswmed Repository record for Optimizing Kilovoltage Cone-Beam Computed Tomography for Image-Guided Radiation Therapy (opens in a new tab)

  3. A dosimetric study of kilovoltage cone beam CT image guidance in gynaecological radiation therapy

    Cone beam CT (CBCT) is increasingly used in image guided radiation therapy in order to ensure more accurate patient setup and target localization. However, the issue of patient dose due to repeated imaging procedures is an important topic in radiation medicine today. This thesis rigorously explores …

    ubc Repository record for A dosimetric study of kilovoltage cone beam CT image guidance in gynaecological radiation therapy (opens in a new tab) Download PDF for A dosimetric study of kilovoltage cone beam CT image guidance in gynaecological radiation therapy (opens in a new tab)

  4. In Vitro Studies of Gold and Gold Silica Nanoparticle Radiosensitization with Kilovoltage X-Rays

    … photoelectric effect vs. tissue with regards to kilovoltage x-rays. Both gold and silica are also relatively inert and biocompatible. The investigation of dose enhancement to cells that have been incubated with nanoparticles and nanoshells is the focus of this thesis. The effectiveness of the …

    unlv Repository record for In Vitro Studies of Gold and Gold Silica Nanoparticle Radiosensitization with Kilovoltage X-Rays (opens in a new tab) Download PDF for In Vitro Studies of Gold and Gold Silica Nanoparticle Radiosensitization with Kilovoltage X-Rays (opens in a new tab)

  5. Low kilovoltage computed tomography to reduce contrast medium dose in patients at risk of acute kidney injury

    … this risk. Decreasing the X-ray tube potential (kilovoltage, kV) from commonly used 120 to 80 kV results in higher CM attenuation due to the photoelectric properties of iodine, which may permit reduction of the iodine dose while keeping the attenuation unchanged. Lower tube potential, however, …

    lund Repository record for Low kilovoltage computed tomography to reduce contrast medium dose in patients at risk of acute kidney injury (opens in a new tab) Download PDF for Low kilovoltage computed tomography to reduce contrast medium dose in patients at risk of acute kidney injury (opens in a new tab)

  6. Design and evaluation of a Monte Carlo model of a low-cost kilovoltage x-ray arc therapy system

    … middle-income countries. This new system uses kilovoltage rather than megavoltage x-rays and is therefore much more cost-effective. The ultimate purpose of this kilovoltage radiation therapy system is to improve access to radiation therapy worldwide by supplementing current radiation therapy …

    uvic Repository record for Design and evaluation of a Monte Carlo model of a low-cost kilovoltage x-ray arc therapy system (opens in a new tab)

  7. Assessment of imaging dose from the kilovoltage cone beam computed tomography system on board the Varian Halcyon linear accelerator

    … frequent nature of imaging sessions mostly using kilovoltage (kV) x-ray energies has raised concerns about the contribution of low-energy radiation dose to the overall integral dose and possible induction of secondary primary tumours. In this study, the dose to organs and tissues located in the …

    cape-town Repository record for Assessment of imaging dose from the kilovoltage cone beam computed tomography system on board the Varian Halcyon linear accelerator (opens in a new tab)

  8. Dosimetric investigations of Kilovoltage Cone Beam Computed Tomography (kV-CBCT) utilized in Image Guided Radiation Therapy (IGRT) using Monte Carlo simulations

    Many studies have shown that the computed tomography dose index (CTDI100) which is considered to be the main dose descriptor for CT dosimetry fails to provide a realistic reflection of the dose involved in cone beam CT (CBCT) scans. The main reason for this failure is that CTDI100 measurements are …

    glasgow Download PDF for Dosimetric investigations of Kilovoltage Cone Beam Computed Tomography (kV-CBCT) utilized in Image Guided Radiation Therapy (IGRT) using Monte Carlo simulations (opens in a new tab)

  9. Intensity Modulated Bolus Electron Conformal Therapy (IM-BECT): Methods for Quality Assurance of PRIME Intensity Modulators and Evaluation of Planned IM-BECT Dose Distributions

    … QA of fabricated treatment devices. (1) A kilovoltage x-ray imaging procedure, developed for factory QA of PRIME devices, was tested by comparing well-fabricated ones with those having significant errors. (2) The IM-BECT planning process and delivery was verified using end-to-end tests for …

    lsu-thes Repository record for Intensity Modulated Bolus Electron Conformal Therapy (IM-BECT): Methods for Quality Assurance of PRIME Intensity Modulators and Evaluation of Planned IM-BECT Dose Distributions (opens in a new tab)

  10. Novel radiation sensors based on bio/nanomaterials

    … measure dose and dose rate of X-ray beam in the kilovoltage and megavoltage energy range. The mass attenuation coefficients, effective atomic numbers and electron densities of BR and its comprising amino acids have been calculated for 1 keV-100 GeV photons to better understand the interaction of …

    waterloo Repository record for Novel radiation sensors based on bio/nanomaterials (opens in a new tab)

  11. Εφαρμογή τρισδιάστατης χημικής δοσιμετρίας στην ακτινοθεραπεία δερματικών νόσων

    Accurate measurements of dose profiles using kilovoltage X ray beams are challenging due to energy dependence of available dosimeters and steep dose gradients demanding high spatial resolution and precise dosimeter positioning. The scope of this thesis is to evaluate the suitability of radiochromic …

    greece Repository record for Εφαρμογή τρισδιάστατης χημικής δοσιμετρίας στην ακτινοθεραπεία δερματικών νόσων (opens in a new tab)

  12. Developing Lower Cost Radiotherapy Solutions for Low and Middle Income Countries

    … current linacs through the elimination of the kilovoltage on-board CT imaging system (kV-OBI). The removal of the kV-OBI would greatly reduce production costs of treatment linacs. However, the removal of the makes many image guided radiotherapy (IGRT) treatments infeasible, treatments which …

    uvic Repository record for Developing Lower Cost Radiotherapy Solutions for Low and Middle Income Countries (opens in a new tab)

  13. An Investigative Study of a Novel Technique of Material Decomposition for Dual Energy Cone Beam Computed Tomography - Technique and Clinical Applications

    … image-guided RT methods become highly desirable. Kilovoltage (kV) cone-beam computed tomography (CBCT) is a common volumetric guidance tool before and during RT. It offers great soft-tissue contrast and submillimeter spatial resolution. Despite the widespread usage of kV CBCT, there are still …

    gatech Repository record for An Investigative Study of a Novel Technique of Material Decomposition for Dual Energy Cone Beam Computed Tomography - Technique and Clinical Applications (opens in a new tab)

  14. FEASIBILITY OF KV SCATTERED X-RAY IMAGING FOR MARKER-FREE TUMOR TRACKING IN LUNG RADIOTHERAPY

    … detection of Compton-scattered photons, making kilovoltage (kV) scattered X-ray imaging a promising approach for marker-free tumor tracking in lung cancer radiotherapy. This work aims to evaluate the feasibility of kV scattered X-ray imaging for real-time tumor localization by investigating the …

    jhu Repository record for FEASIBILITY OF KV SCATTERED X-RAY IMAGING FOR MARKER-FREE TUMOR TRACKING IN LUNG RADIOTHERAPY (opens in a new tab)

  15. Development and Application of a Technique for Three-dimensional Sialography using Cone Beam Computed Tomography

    … (FOV) size and center, x-ray tube peak kilovoltage (kVp) and milliamperage (mA). Next, cbCT image quality, measured using the signal-difference-to-noise-ratio (SDNR) was used to determine those technical factors that optimized image quality. Finally, using the optimized image acquisition …

    toronto-retro Repository record for Development and Application of a Technique for Three-dimensional Sialography using Cone Beam Computed Tomography (opens in a new tab)

  16. Microcomputed tomography dosimetry and image quality in preclinical image-guided radiation therapy

    … improve quality of life. Small targets and low kilovoltage x-rays create challenges that do not arise in clinical radiation therapy. Evidence based on our multi-institutional study reveals a considerable aberration in microCT image quality from one institution to the next. We propose the …

    uvic Repository record for Microcomputed tomography dosimetry and image quality in preclinical image-guided radiation therapy (opens in a new tab)

Page 1 of 2