Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 13 of 13 for “"Kinematic alignment"”
-
Kinematic alignment and total knee arthroplasty
… the concept of implanting TKAs in mechanical alignment (MA) was developed as a compromise to confer mechanical advantage to the prosthesis, ignoring the patient’s natural anatomy, to prevent early failure of the implant. Until now, this compromise has not been revisited. Satisfaction following …
-
Kinematic alignment of precision robotic elements in factory environments
In the measurement and instrumentation fields, kinematic couplings have been widely used to create precise and repeatable interfaces on a variety of devices. However, these devices have been limited to low load and clean environments such as in semiconductor manufacturing facilities. While …
-
Kinematic alignment technique for total knee replacement : rational, current evidence, potential concerns
La pose d’une prothèse totale de genou (PTG) se fait selon la technique d’alignement mécanique (AM) qui corrige les déformations constitutionnelles du membre pour créer un membre rectiligne. La survie à long terme des implants est excellente mais les résultats fonctionnels sont décevants avec …
-
Σύγκριση των αποτελεσμάτων Kinematic alignment και Mechanical alignment στην ολική αρθροπλαστική γόνατος
Ιστορικό: Ιστορικά, η μηχανική ευθυγράμμιση (ΜΑ) χρησιμοποιήθηκε για την επίτευξη ουδέτερων και τυποποιημένων αξόνων στο εμφύτευμα, με σκοπό την παράταση της μακροβιότητας της Ολικής Αρθροπλαστικής Γόνατος (ΟΑΓ). Ωστόσο, η δυσαρέσκεια των ασθενών εξακολουθεί να αποτελεί συχνό πρόβλημα, ως …
-
Biomechanical evaluation of patellofemoral kinematics and interface forces under varying loading conditions in total knee arthroplasty with a novel femoral design for kinematic alignment
… component designs influence the patellofemoral kinematics and the contact forces, and how these effects interact with PR and muscle loading conditions. Twelve paired cadaveric knees were tested in three conditions: native, TKA without PR, and TKA with PR. Six specimens received a traditional …
-
The Relationship of Alignment and Balance in Total Knee Arthroplasty.
It is not known whether restoring constitutional alignment using kinematic alignment (KA) techniques more reliably improves soft tissue balance (STB), or patient reported outcome measures (PROMs) compared to mechanical alignment (MA) in total knee arthroplasty (TKA). The aims of this thesis were to …
-
The Effect of Surgical Alignment and Soft Tissue Constraints on the Kinematics, Contact Pressure and Wear of a Total Knee Replacement
… Previous studies have determined that poor alignment can result in pain, lower knee scores or increased wear. However alignment alone may not result in early failure. Instead it may be the combination of alignment and the soft tissue conditions within the knee that are important. The aim of …
-
Simulating Multiphase Galactic Halos: The Impact of Cosmic Rays Through an Observational Lens
… the observed abundance, properties, and kinematic structure of multiphase CGM gas.In this thesis, I argue that the missing piece is likely a nonthermal component in the form of cosmic rays. I implement cosmic-ray physics into the {\sc enzo} and {\sc ChaNGa} simulation codes and use a …
-
Advancement of a Forward Solution Mathematical Model of the Human Knee Joint
… tool to efficiently assess the kinetics and kinematics of new TKA designs. In general, the knee is one of the most complicated joints in the human body, including multiple articulating surfaces and the complexity of soft tissues encompassing the knee joint. Therefore, mathematically modeling …
-
Biomechanical analysis of Total Knee Arthroplasty performed on a 6 degree of freedom joint motion simulator linked to a virtual ligament model in mechanical and kinematic alignments
… in stability, soft tissue balance, joint kinematics and overall patient satisfaction may lead to a decrease in TKA revisions. It is still unclear what the optimal soft tissue tension, balance or alignment is to provide superior patient outcomes. Computational models provide a means to …
-
Influence de l'implantation d'une prothèse totale de genou sur les contraintes fémoropatellaires lors d'une simulation de squat
La mise en place d’une prothèse totale de genou (PTG) permet un retour aux activités de la vie quotidienne du patient par diminution des douleurs et optimisation des mobilités articulaires dans un contexte de gonarthrose sévère. Bien que les douleurs fémoropatellaires fassent partie des étiologies …
-
Biomechanical Outcomes of Distinct TKA Surgical Alignments and Implant Designs
… decades from traditional post-operative neutral alignment methods with an overall goal of implant longevity to ones that are more personalized to better replicate individual native knee kinematics. Personalizing TKA knee kinematics to better replicate a patient’s native knee kinematics has …
-
Evolution et évaluation de l'alignement dans les prothèses totales de genou
La prothèse totale de genou (PTG) est une intervention fréquente en orthopédie. Lors de la réalisation de la PTG, l’objectif était d’obtenir un alignement mécanique (AM) systématique à 180°. Cette technique permet d’obtenir un membre rectiligne diminuant les contraintes articulaires et in fine …