Showing 1 to 5 of 5 for “"Kinematic sensing"”.

  1. Improved kinematic sensing for motion control applications

    New compensation methods are presented that can greatly reduce the slit errors (i.e. transition location errors) and interval errors induced due to non-idealities in optical incremental encoders (square-wave). An M/T-type, constant sample-time digital tachometer (CSDT) is selected for measuring the …

    cork Repository record for Improved kinematic sensing for motion control applications (opens in a new tab)

  2. Patterned thin-film triboelectric generator for harvesting micro-meso scale ambient energy for kinematic sensing

    … prototype can be extend for 2-D motion direction sensing. The highly pliable sensor can be easily bent to spread over curved and uneven surfaces. Finally, I have demonstrated a quasi-static angular positioning sensor based on 4-channel encoded pattern on the electrification surface. The sensor …

    gatech Repository record for Patterned thin-film triboelectric generator for harvesting micro-meso scale ambient energy for kinematic sensing (opens in a new tab)

  3. A multimodal execution monitor for assistive robots

    … system with haptic, visual, auditory, and kinematic sensing during household tasks and human-robot interactive tasks including feeding assistance. We show multimodality improves the performance of monitoring methods by detecting and classifying a broader range of anomalies. Overall, our …

    gatech Repository record for A multimodal execution monitor for assistive robots (opens in a new tab)

  4. An electrogoniometer to measure spinal curvature

    … mechanical structure and the analysis of spinal kinematics, in conjunction with spinal loading, offers a method for analysing therapeutic interventions.Numerous motion capture systems and devices are currently available, each with its own strengths and weaknesses. The systems or devices selected …

    strathclyde Repository record for An electrogoniometer to measure spinal curvature (opens in a new tab)

  5. Collaborative human-machine interfaces for mobile manipulators.

    … non-linearities, including drive train backlash, kinematic or dynamic coupling, variable patient pushing effort, or slope surfaces with unknown inclines. The advantage of our control strategy consists of Lyapunov stability guarantees during interaction, less need for parameter tuning and better …