Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 22 for “"Kinetic inductance detector"”
-
A proof of concept double tone readout for kinetic inductance detector bolometers
Microwave kinetic inductance detectors (MKIDs) are a detector technology based on the change of the resonant frequency due to the hit of a photon. This technology is attractive for low-energy detectors as used in astronomy. The MKID technology enables to place multiple detectors in the same feed …
-
Design and Simulation of a Microwave Kinetic Inductance Detector Spectrograph for Astronomy
This thesis presents a Microwave Kinetic Inductance Detector (MKID) spectrograph concept, the Kinetic Inductance Detector Spectrometer (KIDSpec). MKIDs are superconducting photon-counting detectors that can resolve the energy of incoming photons and their time of arrival. KIDSpec will use these …
-
SuperSpec: Development and Characterization of Kinetic Inductance Detector-Based On-Chip Spectrometer for Millimeter and Sub-Millimeter Observations
… architecture in which Titanium Nitride kinetic inductance detectors (KIDs) are coupled to mm-wave resonant filters along a single microwave feedline. The detector's small size and and natural multiplexability compared to traditional grating spectrometers will enable future multi-object …
-
Conception et développement de détecteurs à inductance cinétique pour l'astronomie millimétriques et les rayons X
… de détecteur cryogénique, appelé Lumped Element Kinetic Inductance Detector, pour l'application dans l'astronomie millimétrique et la détection de photons de haute énergie. Concernant l'astrophysique, l'objectif était d'élaborer des grandes matrices de détecteurs qui montrent une sensibilité …
-
Building The Next Generation Blast Experiment
… experiment which features three microwave kinetic inductance detector (MKID) arrays operating over 30% bandwidths centered at 250, 350, and 500 μm. These highly- multiplexed, high-sensitivity arrays, featuring 918, 469, and 272 dual-polarization pixels, are coupled to a 2.5 m diameter …
-
Magnetic Fields in Molecular Clouds: The Blastpol and Blast-Tng Experiments
… mirror and more than 3000 polarization sensitive detectors. BLAST-TNG will observe in the same three bands as BLASTpol at 250, 350, and 500 microns. The telescope will serve as a pathfinder project for microwave kinetic inductance detector (MKID) technology, as applied to feedhorn coupled …
-
Polychromatic measurement of the wavefront for high-contrast imaging with an MKID-based Pyramid Wavefront Sensor.
… by its non-linear behaviour. Existing CCD/CMOS detector technology is well suited to PWFS operation, providing near-zero read noise detectors with frame rates of 1 - 3 kHz at either visible or near-infrared wavelengths. However, there is little scope for significant improvement in these detector …
-
Détecteurs à inductance cinétique pour l'astronomie millimétrique : étude des matériaux et des procédés de fabrication
Depuis 10 ans, les détecteurs à inductance cinétique (Kinetic Inductance Detector KID) ont connu un essor considérable dans le domaine de la radioastronomie millimétrique pour atteindre des limites de sensibilités de l'ordre du bruit de photon. Le détecteur à inductance cinétique est un résonateur, …
-
Blast-Tng And A Study Of Molecular Clouds
… through the use of three kilopixel microwave kinetic inductance detector(MKID) arrays which were centered at 250, 350, and 500μm with a 30% fractional bandwidth. The arrays were cooled to 275 mK in a cryogenic receiver which was coupled to a 2.5 m primary telescope providing …
-
Advances in Microwave and Sub-mm Astronomical Instrumentation and Analysis
… will be required to prevent the Microwave Kinetic Inductance Detector (MKID) from saturating. We also find a lower detector responsivity value would be needed for the 850 GHz array compared to 250 and 350 GHz arrays. Finally, we push to an even higher resolution by designing the …
-
Superconducting Microwave Resonators for Cosmology and Astrophysics with CCAT
… require unprecedented numbers of superconducting detectors operating at nearly the fundamental limits of sensitivity. One such detector technology is the kinetic inductance detector (KID), a superconducting resonator that allows for natural multiplexing and photon-limited performance. Prime-Cam, …
-
Techniques de microscopie sous-longueur d'onde aux fréquences térahertz
… habituellement utilisé en astronomie : les KIDs (kinetic inductance detector). Après avoir présenté les principes physiques mis en jeu dans de tels détecteurs, ce manuscrit décrit la caractérisation qui a été faite d’une caméra KIDs. A l’aide d’un montage « classique » de spectroscopie dans le …
-
Low-temperature characterization of dielectric loss at microwave frequencies in aluminum oxide
… quantum computer and as ultra-sensitive detectors. Superconducting resonators are one type of superconducting device which are used in a variety of applications including quantum computing and radioastronomy. They can achieve large quality factors which are important for these …
-
Measuring the Sunyaev-Zel'dovich Effects with Current and Future Observatories
… of large numbers of sensitive superconducting detectors in novel cryogenic receivers. In this thesis we present the design of a first light instrument for the Fred Young Submillimeter Telescope (FYST), Mod-Cam, which will be used to deploy the first light microwave kinetic inductance detector …
-
Optical, mechanical, and detector developments for the Prime-Cam 850 GHz module
… spacing, beam size, pixel sensitivity, and detector count. The optimization of an optical design for the 850 GHz instrument module for CCAT-prime is also presented. Success of the 850 GHz module hinges on the development of state-of-the-art, photon-noise-limited kinetic inductance detector …
-
Development of Kinetic Inductance Detectors for mm and sub-mm Observations
Kinetic inductance detectors (KIDs) are a type of athermal pair-breaking superconductingdetectors. Several superconductors have an energy gap on the order of 0.1eV, which makes KIDs well-suited for mm and sub-mm wave observations. Compared to their counterparts in this regime, KIDs have innate …
-
Development of Kinetic Inductance Detectors for mm and sub-mm Observations
Kinetic inductance detectors (KIDs) are a type of athermal pair-breaking superconductingdetectors. Several superconductors have an energy gap on the order of 0.1eV, which makes KIDs well-suited for mm and sub-mm wave observations. Compared to their counterparts in this regime, KIDs have innate …
-
The terahertz intensity mapper: development of the cryogenic receiver
Submission original under an indefinite embargo labeled 'Open Access'. The submission was exported from vireo on 2026-02-19 without embargo terms
-
Development of superconducting microwave resonators for terahertz intensity mapping from balloon and space
Submission original under an indefinite embargo labeled 'Open Access'. The submission was exported from vireo on 2023-09-01 without embargo terms
-
Matrices LEKIDs grand format pour l'astronomie millimétrique
… plan focal de 80 mm, des réseaux de détecteurs à inductance cinétique (LEKID) de 4 pouces de diamètre sont installés. Les LEKID se sont développés rapidement au cours de la dernière décennie grâce à leur structure simple, leurs dimensions adaptables et le besoin de matrices de détecteurs grand …
Page 1 of 2