  1. Millimeter-Wave Reflex Klystron Amplifier

    … experimentation with M-band regenerative reflex klystron amplification, a peculiar pull-in behavior of the tube under test was noted by the writer. Upon discussing this pull-in phenomenon with the writer's thesis advisor, it was decided that if subsequent investigation confirmed initial …

    marquette Repository record for Millimeter-Wave Reflex Klystron Amplifier (opens in a new tab)

  2. Numerical simulation of a relativistic klystron

    … of an extended interaction relativistic klystron is developed. The relativistic klystron consists of several discrete elements. These elements are a deflector cavity, a sector field magnet, a microwave resonator, a solenoid, and the drift spaces between each element. A derivation of the …

    ttu Repository record for Numerical simulation of a relativistic klystron (opens in a new tab)

  3. Klystron frequency stabilization with a pound discriminator

    … source constructed made use of a reflex klystron and a Pound discriminator. The components of the system, the klystron, the discriminator, and the amplifier, are analyzed and their calculated and actual performance presented. It is shown that the Pound discrimiator can be made more …

    rice Repository record for Klystron frequency stabilization with a pound discriminator (opens in a new tab)

  4. Cavité de type klystron pour des dispositifs microondes

    Les propriétés électriques des matériaux sont des données indispensables dans les phases de conception de circuits micro-ondes. Ainsi, de nombreuses méthodes ont été mises au point en s’appuyant sur des mesures de paramètres «S», pour les systèmes de transmission-réflexion, ou de fréquences de …

    star-france Repository record for Cavité de type klystron pour des dispositifs microondes (opens in a new tab)

  5. High power high efficiency multiple-beam klystron design

    … optimisation methods of a 1.3 GHz Multiple Beam Klystron (MBK) for use in the Compact Linear Collider (CLIC). In this regard refinements have been made both to the MBK design, and investigation and optimisation methods used. The high desired efficiency of 80% requires low perveance beams, to …

    lancaster Repository record for High power high efficiency multiple-beam klystron design (opens in a new tab)

  6. Iterative methods for stagger-tuning multiclavity klystron amplifiers.

    … adjustment of the tuning of multicavity klystron amplifiers for prescribed frequency response. The method used is an iterative process developed at Stanford University in 1952. The purpose of the investigation was to test the applicability of the iterative method to the design of …

    ubc Repository record for Iterative methods for stagger-tuning multiclavity klystron amplifiers. (opens in a new tab)

  7. Klystron-frequency stabilization for a paramagnetic-resonance spectrometer

    The requirements for the frequency stability of a microwave oscillator for use in a paramagnetic-resonance spectrometer are discussed. A design for a frequency-stabilization system, which is based on developments by R. V. Pound, is presented. Tests show that the system has a short-time stability of …

    rice Repository record for Klystron-frequency stabilization for a paramagnetic-resonance spectrometer (opens in a new tab)

  8. Simulation of proposed 20 kW klystron free electron laser

    … maintaining less than 6% energy spread. Using a klystron undulator is one potential way to accomplish this. Given design parameters of a proposed free electron laser by TJNAF, this study quantifies via simulation the behaviors of gain, power and energy spread as functions of desynchronism and a …

    nps Repository record for Simulation of proposed 20 kW klystron free electron laser (opens in a new tab)

  9. Resonant Cavity Studies of a Wide Range Tunable Klystron

    Made available in DSpace on 2014-12-04T21:02:27Z (GMT). No. of bitstreams: 1 0001551.pdf: 10984137 bytes, checksum: 4930bbd00c3219734918ae3c9aab607b (MD5) Previous issue date: 1949

    uiuc Repository record for Resonant Cavity Studies of a Wide Range Tunable Klystron (opens in a new tab)

  10. Frequency stabilization of a klystron in a paramagnetic resonance spectrometer

    … use as a wide band Instrument employs a reflex klystron. The frequency of the klystron has been stabilized to at least one part in one quarter million, over a period of a few hours, to the resonant frequency of a microwave cavity. A variation of the A.C. Pound stabilizing circuit was employed. …

    ubc Repository record for Frequency stabilization of a klystron in a paramagnetic resonance spectrometer (opens in a new tab)

  11. Design and Control of Long-Pulse High-Power Klystron Modulators

    … in the world. The ESS linac is powered by klystron modulators required to deliver long high-power pulses (pulse amplitude 115 kV/100 A, pulse length 3.5 ms, pulse repetition rate 14 Hz) of very high quality (combined flat top ripple and droop < 0.15% of the pulse amplitude, pulse-to-pulse …

    lund Repository record for Design and Control of Long-Pulse High-Power Klystron Modulators (opens in a new tab)

  12. Développement et réalisation d'un klystron à haut-rendement de type kladistron

    Les klystrons sont des tubes électroniques dans lesquels un ou plusieurs faisceaux d'électrons sont modulés afin de d'amplifier un signal radiofréquence. Pour ce faire, des cavités passives constituant la ligne d’interaction du klystron échangent de l’énergie électromagnétique avec le faisceau. Il …

    star-france Repository record for Développement et réalisation d'un klystron à haut-rendement de type kladistron (opens in a new tab)

  13. Development of Numerical Simulation Codes and Application to Klystron Efficiency Enhancement

    … beams aiming at appreciable enhancements of klystron efficiencies. Also presented are developments of a set of 2-dimensional numerical codes to investigate these two approaches. The results are summarized as follows. (i) A new Finite Element eigenmode solver (KUEMS) has been developed in this …

    kyoto Repository record for Development of Numerical Simulation Codes and Application to Klystron Efficiency Enhancement (opens in a new tab)

  14. On the selection of tuning patterns in stagger-tuning multicavity klystron amplifiers

    … maximally-flat response for the multicavity klystron amplifier, a choice must be made in allocating poles to cavities. In this thesis, a method is described for selecting the tuning pattern which will give flat response with maximum gain for a specific multicavity klystron. The iterative …

    ubc Repository record for On the selection of tuning patterns in stagger-tuning multicavity klystron amplifiers (opens in a new tab)

  15. Development of a 500 MW, one-microsecond, multi-kiloampere relativistic klystron amplifier

    … on the one-microsecond, L-band relativistic klystron amplifier (RKA) project conducted at Los Alamos National Laboratory. A collection of theoretical analyses is presented for rf cavities, intense electron beams, beam-cavity interactions, and small-signal klystron bunching. Electromagnetic …

    rice Repository record for Development of a 500 MW, one-microsecond, multi-kiloampere relativistic klystron amplifier (opens in a new tab)