Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 21 for “"Knudsen Cell"”.

  1. Molecular Thermodynamics and Knudsen Cell - Mass Spectrometer Studies of Liquid Metal Mixtures

    Made available in DSpace on 2014-12-13T18:55:34Z (GMT). No. of bitstreams: 1 7709140.pdf: 5295489 bytes, checksum: 35b97660db8ded30f6f94b9965342212 (MD5) Previous issue date: 1976

    uiuc Repository record for Molecular Thermodynamics and Knudsen Cell - Mass Spectrometer Studies of Liquid Metal Mixtures (opens in a new tab)

  2. A Knudsen cell for controlled deposition of L-cysteine and L-methionine on Au(111)

    … a primary focus on the design and testing of a Knudsen cell for controlled deposition of L-cysteine and L-methionine. An ultra-high vacuum preparation chamber designed by Dr. Katie Mitchell and built by Torrovap Industries Inc. was installed. This chamber is connected to the existing scanning …

    sask Repository record for A Knudsen cell for controlled deposition of L-cysteine and L-methionine on Au(111) (opens in a new tab)

  3. Development of a Knudsen Cell Reactor for Measuring the Uptake of Atmospheric Gases on Particulate Matter

    … on particulates found in the environment. A Knudsen cell was designed and constructed for providing precise measurement of reaction probabilities within these systems. The instrument was validated through a series of experiments. After validating the Knudsen cell against several key …

    vt Repository record for Development of a Knudsen Cell Reactor for Measuring the Uptake of Atmospheric Gases on Particulate Matter (opens in a new tab)

  4. Design of High Temperature Evaporator for Spectroscopic Study of Equilibrated Vapor Phase Materials

    … H2O/SiO2 equilibrated atmospheres within a Knudsen cell. Modeling of exoplanet spectra can be used to determine spectral photometry results as seen by astronomers for comparison with reference spectra collected.

    mo-state Repository record for Design of High Temperature Evaporator for Spectroscopic Study of Equilibrated Vapor Phase Materials (opens in a new tab)

  5. Matrix isolation fourier transform infrared spectroscopy of nitro polycyclic aromatic hydrocarbons

    … was demonstrated. Samples were vaporized in a Knudsen cell and co-deposited on a Csl window cooled to 15 K in order to obtain matrix isolated spectra.</p> <p>Spectra of twelve compounds were obtained to form a partial library of matrix isolated nitro-PAH. Qualitative studies demonstrated the …

    ut-knoxville Repository record for Matrix isolation fourier transform infrared spectroscopy of nitro polycyclic aromatic hydrocarbons (opens in a new tab)

  6. ΜΕΛΕΤΗ ΣΥΣΤΗΜΑΤΩΝ ΙΩΔΙΟΥΧΩΝ ΛΑΝΘΑΝΙΔΩΝ-ΙΩΔΙΟΥΧΩΝ ΑΛΚΑΛΙΩΝ ΜΕ ΦΑΣΜΑΤΟΣΚΟΠΙΑ RAMAN ΚΑΙ ΦΑΣΜΑΤΟΜΕΤΡΙΑ ΜΑΖΑΣ

    … AND THESYSTEM ERI3-NAI WAS STUDIED WITH KNUDSEN CELL MASS SPECTROMETRY. THE SCI3-CSI SYSTEM IS USED IN HIGH INTENSITY DISCHARGE MERCURY LAMPS, IN ORDER TO IMPROVE THE COLOR OF THE LAMP. THE STUDY WAS AIMED AT DETERMINING THE MELT STRUCTURE, WHICH IS THE FIRST STEP FOR EXPLAINING THE HIGH …

    greece Repository record for ΜΕΛΕΤΗ ΣΥΣΤΗΜΑΤΩΝ ΙΩΔΙΟΥΧΩΝ ΛΑΝΘΑΝΙΔΩΝ-ΙΩΔΙΟΥΧΩΝ ΑΛΚΑΛΙΩΝ ΜΕ ΦΑΣΜΑΤΟΣΚΟΠΙΑ RAMAN ΚΑΙ ΦΑΣΜΑΤΟΜΕΤΡΙΑ ΜΑΖΑΣ (opens in a new tab)

  7. Thermodynamics of magnesium in liquid nickel solutions

    … magnesium over the alloys. A radiatively heated Knudsen cell inside a vacuum system contains the metal. Equilibrium constants are given for the reactions, [Formula Omitted] where Al, 0 and Mg are dissolved in liquid nickel. Further, values for the metal-oxygen interaction coefficients [Formula …

    ubc Repository record for Thermodynamics of magnesium in liquid nickel solutions (opens in a new tab) Download PDF for Thermodynamics of magnesium in liquid nickel solutions (opens in a new tab)

  8. Development of a Method to Determine Vapor Pressure Data of Low Volatile Chemicals from a Knudsen Effusion Technique

    … determined by conventional means. An isothermal Knudsen effusion technique was designed and developed in our laboratory for such measurements. The effusion mass as a function of time is measured in our technique using a thickness shear mode (TSM) acoustic wave sensor, which allows for extremely …

    usf Repository record for Development of a Method to Determine Vapor Pressure Data of Low Volatile Chemicals from a Knudsen Effusion Technique (opens in a new tab)

  9. Atomic Beam Laser-cooled Ion Source : towards sub-nm ion beam milling

    … a beam of atomic rubidium is created from a Knudsen cell. This beam is laser-cooled and -compressed after which it is photo-ionized by means of a very intense laser. The ions will be accelerated immediately to their demanded energy (mostly 30 keV) and finally focused to an as small as …

    eindhoven Repository record for Atomic Beam Laser-cooled Ion Source : towards sub-nm ion beam milling (opens in a new tab) Download PDF for Atomic Beam Laser-cooled Ion Source : towards sub-nm ion beam milling (opens in a new tab)

  10. Atomic beam source for the ultracold focused ion beam setup

    … generation of the atomic beam is done using a Knudsen cell; an effusive oven containing a vapor of rubidium atoms. The pressure difference between the vapor pressure in the oven and the vacuum outside the oven generates a flow of atoms from the oven to the vacuum. Only atoms that have a low …

    eindhoven Repository record for Atomic beam source for the ultracold focused ion beam setup (opens in a new tab) Download PDF for Atomic beam source for the ultracold focused ion beam setup (opens in a new tab)

  11. On-surface synthesis of two-dimensional conducting metal-organic frameworks

    … substrate. Following vapour deposition from a Knudsen cell, HHTP molecules self-assemble into a near close-packed phase with two alternating molecular rows. After reacting with transition metals (Ni/Co), HHTP forms a dense structure on the surface. The metal centres adopt a three-fold …

    oxford Repository record for On-surface synthesis of two-dimensional conducting metal-organic frameworks (opens in a new tab)

  12. Investigations of Na gas-melt interactions of melt droplets and precursors: Implications for chondrule formation

    … placed in the bottom of the furnace. Succeeding Knudsen cell weight-loss mass-spectrometry analysis of NaCl determined the PNa for these experimental conditions to be in the 10⁻⁶ atm range. In these trials the Na2O content of the glass was maintained or in some cases increased; Na2O values ranged …

    iastate Repository record for Investigations of Na gas-melt interactions of melt droplets and precursors: Implications for chondrule formation (opens in a new tab)

  13. Malonaldehidų šeimos molekulių tyrimas Matricinės izoliacijos FTIR spektriniu metodu /

    … Due to the molecule’s low volatility, the Knudsen cell method was employed to enable its introduction into the experimental system. The main objectives of the study were to determine possible molecular conformations, to record infrared absorption spectra of the isolated molecule, and to …

    vilnius Repository record for Malonaldehidų šeimos molekulių tyrimas Matricinės izoliacijos FTIR spektriniu metodu / (opens in a new tab)

  14. A mass spectrometric investigation of the volatile content of deep submarine basalts

    High temperature Knudsen-cell quadrupole mass spectrometry has been used to identify and determine amounts of gases contained in deep submarine basalt glassy rims and glass-vapor inclusions found in associated phenocrysts. Samples analyzed were from three different geologic settings: ocean ridges; …

    hawaii Repository record for A mass spectrometric investigation of the volatile content of deep submarine basalts (opens in a new tab)

  15. Organic electronic and photonic devices based on pentacene and modified oligo-p-phenylenevinylenes

    … thin films were grown in high vacuum using a Knudsen cell. The substrate temperature was held between room temperature and 225&deg;C. The resulting films were characterized by powder x-ray diffraction and atomic for microscopy. Both of these techniques indicated that the thin films formed a …

    ottawa-retro Repository record for Organic electronic and photonic devices based on pentacene and modified oligo-p-phenylenevinylenes (opens in a new tab)

  16. Structural analysis of heptanoic acid using theoretical and experimental methods of vibrational spectroscopy /

    … superior method for conformational analysis. Knudsen cell was also employed to bring the sample as close as possible to the cryogenic IR window, which in turn compensated for the very low saturated vapor pressure of heptanoic acid. These measurements were performed using \textit{Bruker} "IFS …

    vilnius Repository record for Structural analysis of heptanoic acid using theoretical and experimental methods of vibrational spectroscopy / (opens in a new tab)

  17. Growth of doped transparent conducting oxides by oxygen plasma assisted atomic beam epitaxy

    … coatings for display technologies, solar cells, and optoelectronics. Since many of the applications require the use of thin film forms, the need is to establish useful experimental approaches to the fabrication of such structures. One relatively new method in this area is oxygen-plasma …

    oxford Repository record for Growth of doped transparent conducting oxides by oxygen plasma assisted atomic beam epitaxy (opens in a new tab)

  18. Vapor Pressures and Thermodynamic Properties of Mg(BH4)2, KBH4 and RbBH4 Using Torsion-Effusion and Thermogravimetric Method

    … and 165 °C to 216 °C, and using two molybdenum Knudsen cells with orifice diameters of 0.3 mm and 0.6 mm respectively. Moderate pressures of 10-5 torr were employed in these experiments. Based on our measurements between 165 °C - 263 °C, we propose that Mg(BH4)2 disproportionates to form …

    unr Repository record for Vapor Pressures and Thermodynamic Properties of Mg(BH4)2, KBH4 and RbBH4 Using Torsion-Effusion and Thermogravimetric Method (opens in a new tab)

Page 1 of 2