  1. Factors causing delay of modification projects at Koeberg Power Station

    … are common in construction projects, and at Koeberg Nuclear Power Station, modification and outage projects are not exempted from these delays. Subsequently, these project delays have a detrimental effect on the Eskom organization in terms of its mandate to supply electricity to promote and …

    cape-town Repository record for Factors causing delay of modification projects at Koeberg Power Station (opens in a new tab)

  2. Sensitivity analysis of the secondary heat balance at Koeberg Nuclear Power Station

    At Koeberg Nuclear Power Station, the reactor thermal power limit is one of the most important quantities specified in the operating licence, which is issued to Eskom by the National Nuclear Regulator (NNR). The reactor thermal power is measured using different methodologies, with the most …

    cape-town Repository record for Sensitivity analysis of the secondary heat balance at Koeberg Nuclear Power Station (opens in a new tab)

  3. Signature analysis of the primary components of the Koeberg nuclear power station

    … commitment to safe nuclear power generation, the Koeberg Nuclear Power Station (KNPS) replaced the outdated vibration monitoring system with a modern on-line vibration monitoring system. This will allow plant personnel to monitor components on a continuous basis which will provide faster response …

    nwu-za Repository record for Signature analysis of the primary components of the Koeberg nuclear power station (opens in a new tab)

  4. Evaluation of an advanced fault detection system using Koeberg nuclear power plant data

    The control and protection system of early nuclear power plants (Generation II) have been designed and built on the then reliable analog system. Technology has evolved in recent times and digital system has replaced most analog technology in most industries. Due to safety precautions and robust …

    nwu-za Repository record for Evaluation of an advanced fault detection system using Koeberg nuclear power plant data (opens in a new tab)

  5. Optimisation of the Koeberg nuclear power plant controls by implementing customised transfer functions

    Koeberg Nuclear Power Station, like most of the current operating plants, was built with the technology of the 1970s and 1980s. Most of the plants build around that time were using analog technology (IAEA, 1999). The shift in technological development has led to the progression of digital …

    nwu-za Repository record for Optimisation of the Koeberg nuclear power plant controls by implementing customised transfer functions (opens in a new tab)

  6. A probabilistic fracture mechanics model for the tubing degradation of the Koeberg steam generators

    … The current maintenance regime at the Koeberg Nuclear Power Station (near Cape Town, South Africa) utilises tube plugging (when cracks exceed a certain length limit) and online leak detection (based on detection of radioactive Nitrogen 16) as the main means of ensuring safe SG …

    cape-town Repository record for A probabilistic fracture mechanics model for the tubing degradation of the Koeberg steam generators (opens in a new tab)

  7. The effect of chlorine, heat and physical stress on entrained plankton at Koeberg Nuclear Power Station

    The large volume of seawater used for cooling at Koeberg Nuclear Power Station contains many planktonic organisms which are exposed to heat, chlorine and physical stress during their passage through the system. Phytoplankton biomass, measured as chlorophyll a, was reduced by an average of 55.32% …

    cape-town Repository record for The effect of chlorine, heat and physical stress on entrained plankton at Koeberg Nuclear Power Station (opens in a new tab)

  8. 'n Besluitnemings ondersteuningsmodel vir die bepaling van die mees geskikte wisselboustelsel-ritme vir gemengde graanboerderye in die Koeberg

    Weens die unieke eiesoortigheid van die mens is sy behoeftes vanselfsprekend uiters divers. Wat vir die een persoon prioriteit is, mag vir sy buurman geensins belangrik wees nie. Dit is egter ook ’n gegewe, dat die mens heelwat gemeenskaplike ervarings, emosies en behoeftes deel. Een hiervan is die …

    nmmu Repository record for 'n Besluitnemings ondersteuningsmodel vir die bepaling van die mees geskikte wisselboustelsel-ritme vir gemengde graanboerderye in die Koeberg (opens in a new tab)

  9. Long-term reactivity transient analysis in an extended loss of all AC power at the Koeberg nuclear plant

    … neutronics and thermodynamic modelling of the Koeberg Nuclear Station, a 900 MW pressurized water reactor (PWR), whether extended loss of all AC power (ELAP) scenarios will result in an uncontrolled return to criticality. The purpose is to determine whether recriticality can be avoided without …

    cape-town Repository record for Long-term reactivity transient analysis in an extended loss of all AC power at the Koeberg nuclear plant (opens in a new tab)

  10. Introducing a neutron detector model into the oscar 3 calculational code system and validation with Koeberg reactor calculations

    … MGRAC, to perform core calculations for the Koeberg reactor so as to validate the detector model that is being developed in this study. The measure of determining the detector response used in this study is referred to as the detector constant and is taken to be the 235U microscopic fission …

    nwu-za Repository record for Introducing a neutron detector model into the oscar 3 calculational code system and validation with Koeberg reactor calculations (opens in a new tab)

  11. The Relevance Of Load Following Capability Of Nuclear Power Plant For The South African Grid

    … or not. In this report the relevance of Koeberg Nuclear Power Plant to adapt to the demand is examined and the effects on plant operation simulated. The report analyses the operation of the existing nuclear power plant (Koeberg units) in South Africa and describes the regulations that …

    cape-town Repository record for The Relevance Of Load Following Capability Of Nuclear Power Plant For The South African Grid (opens in a new tab)

  12. Investigation into transient stability of a nuclear power plant using DIgSILENT

    … a limited number of generation sources, namely Koeberg Nuclear Power Station (base supply) along with other power stations used for peak load running such as Ankerlig, Palmiet, etc. Koeberg Nuclear Power Station is located at the end of a long transmission line with no other base-load generation …

    cape-town Repository record for Investigation into transient stability of a nuclear power plant using DIgSILENT (opens in a new tab)

  13. HIV/AIDS-related stigma in the South African construction industry: the case of ESKOM

    … are: to determine the current attitude and views Koeberg employees have towards HIV/AIDS; to determine if the stigma of HIV/AIDS prevents Koeberg employees from accessing HIV intervention programmes offered at Koeberg; and to determine the percentage of Koeberg employees utilising the HIV …

    cape-town Repository record for HIV/AIDS-related stigma in the South African construction industry: the case of ESKOM (opens in a new tab)

  14. Seasonal and long-term change in the abundance, accumulation and distribution of beach litter within Table Bay, Cape Town, South Africa

    … popular recreational beach near the city, while Koeberg is a seldom visited beach in a nature reserve 39 km from the city. Daily sampling was conducted for ten days in winter (August), spring (October) and summer (November-December) 2019. Of the 39 602 items (116.6 kg) sampled in 2019, plastics …

    cape-town Repository record for Seasonal and long-term change in the abundance, accumulation and distribution of beach litter within Table Bay, Cape Town, South Africa (opens in a new tab)

  15. The abundance, distribution and accumulation of plastic debris in Table Bay, Cape Town, South Africa

    … 12 km from the city centre, whereas the other (Koeberg) is situated in a nature reserve, with limited access by the general public, and is 27 km farther from the city. Daily accumulation rates of manufactured items (>1 cm diameter) were measured at both beaches for ten days in October, November …

    cape-town Repository record for The abundance, distribution and accumulation of plastic debris in Table Bay, Cape Town, South Africa (opens in a new tab)

  16. Investigation into open phase faults on transmission circuits.

    … of the transmission high voltage yard at Koeberg Power Station. The investigation utilised the Koeberg network configuration, power system data, and protection settings in order to simulate the fault and validate the results with the simulation model. The simulation model was tested by …

    ukzn Repository record for Investigation into open phase faults on transmission circuits. (opens in a new tab)

  17. Effects of thermal stresses on Pressurised Water Reactor nuclear containment vessels following a Loss of Coolant Accident with assimilated containment filtered venting system

    … with simulated scenarios performed at the Koeberg Nuclear Power Station as a case study. The accidents were simulated using the Koeberg engineering simulator to obtain the output data. The scenario for the proposed model correlates the critical mass flow from a double-ended guillotine break …

    cape-town Repository record for Effects of thermal stresses on Pressurised Water Reactor nuclear containment vessels following a Loss of Coolant Accident with assimilated containment filtered venting system (opens in a new tab)

  18. Criticality study of a spent fuel pool using SCALE 6.2.3 and MCNP6.2

    … to the unavailability of specifications of the Koeberg reactor and spent fuel pool, open-source literature has been used with assumptions that enable the development of a methodology and data to be relevant to Koeberg. This is the initial effort to perform spent fuel pool studies. The purpose of …

    nwu-za Repository record for Criticality study of a spent fuel pool using SCALE 6.2.3 and MCNP6.2 (opens in a new tab)

  19. The effects of safety culture on project performance in high risk industries

    Projects are undertaken at Koeberg Nuclear Power Station in South Africa to enhance safety and to contribute to the continuity of power supply in the country. These projects are undertaken in an industry that is regarded as a high risk due to the potential consequence of a nuclear accident. Focus …

    cape-town Repository record for The effects of safety culture on project performance in high risk industries (opens in a new tab)

  20. Thermal–fluid simulation of nuclear steam generator performance using Flownex and RELAP5/mod3.4

    … the models were based on technical drawings from Koeberg Nuclear Power Plant, and were simplified to a one-dimensional model. Plant data obtained from Koeberg was used to validate the models at 100%, 80% and 60% power output. It was found that the overall heat transfer rate predicted with the …

    nwu-za Repository record for Thermal–fluid simulation of nuclear steam generator performance using Flownex and RELAP5/mod3.4 (opens in a new tab)