Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 17 of 17 for “"LCC HVdc"”.
-
Modelling and control of hybrid LCC HVDC System
A novel hybrid HVDC system is proposed based on the traditional LCC HVDC system. The proposed system is able to achieve full elimination of commutation failures which cannot be achieved in traditional LCC HVDC systems. In addition, reactive power controller is designed for the hybrid HVDC system. …
-
Location of open conductor faults on LCC-HVdc transmission systems
High voltage direct current (HVdc) transmission systems are widely used for bulk energy transmission over large distances and the impact of short circuit faults on dc lines in these systems have been extensively studied. However, a type of fault that has hitherto not widely been investigated is the …
-
Extended-frequency dynamic phasor modelling of LCC-HVDC systems for electromagnetic transient simulations
A new model for line-commutated converter (LCC) HVDC systems based upon the concept of extended-frequency dynamic phasors is developed in an electromagnetic transient (EMT)-based simulation platform. The proposed model is capable of representing LCC-HVDC converters during normal as well as abnormal …
-
A converter-enhanced synchronous compensator for LCC-HVDC links feeding weak AC systems
High Voltage Direct Current (HVdc) technology is critical for bulk power transmission and renewable integration. While Line-Commutated Converters (LCC-HVdc) remain standard for high-power applications, they require high Short-Circuit Ratios and demand extensive reactive power. Conventional …
-
Commutation failure prediction and interaction mechanism of Multi-Infeed LCC-HVDC systems under asymmetrical faults
Line-Commutated Converter based HVDC (LCC-HVDC) systems have been widely used for long-distance bulk power transmission and will play a vital role in the future decarbonised power systems since renewable energy resources are normally far away from load centres. As a frequent dynamic event in …
-
Commutation Failure Prevention for HVDC Improvement in algorithm for commutation failure prevention in LCC HVDC
Line commutated HVDC systems are widely used due to their high power ratings. However, one of the disadvantages of such HVDC systems is the high risk of commutation failures when AC disturbances arise. These failures normally develop in the inverter station. When failed commutation occurs, the LCC …
-
Proteção de linhas de transmissão aéreas de sistemas LCC-HVDC monopolares baseada em ondas viajantes utilizando um terminal
… direct current transmission lines systems, LCC (Line Commutated Converter) systems, present great lengths, which increase the fault occurrence rate and, consequently, the demands on the protection methods. A transmission line protection with fast actuation is indispensable, because avoid …
-
A simulation-based optimisation method to evaluate dynamic compensators for the improvement of LCC-HVDC performance in high source impedance power systems
Line commutated converter (LCC) high voltage direct current (HVDC) link dynamic performance is negatively affected by low alternating current (AC) system short circuit ratio (SCR) as viewed from the LCC-HVDC link converter stations. This is particularly evident at LCC-HVDC link converter stations …
-
Modeling and Control of Wind Generation and Its HVDC Delivery System
… generation and its High Voltage Direct-Current (HVDC) delivery system. First of all, modeling of the Doubly-fed Induction Generator (DFIG)-based wind farm is presented including dynamic models of the wind turbine, shaft system and DFIG. Detailed models of the rectifier and inverter of HVDC are …
-
LCC Based Multi-Terminal HVDC Operation without Telecommunication
… into a rebirth of High Voltage Direct Current (HVDC) transmissions in the last two decades. Nowadays, a Line-Commutated Converter (LCC) HVDC is a dominant technology for high power transmission over long distances. Typically, point-to-point configuration HVDC systems are used. However, in a case …
-
Improved HVdc dynamic performace via phase locking to virtual Thévenin voltage
… is introduced and evaluated for application in HVdc systems. As compared with the conventional Trans-vector PLL method, it is shown that the enhanced tracking ability of the IC-PLL improves the dynamic performance of the HVdc system. The thesis shows that these benefits accrue in LCC-HVdc …
-
Modeling line-commutated converter HVDC transmission systems using dynamic phasors
… phasor model of a line-commutated converter (LCC) high-voltage direct current (HVDC) transmission system. The mathematical definition and properties of dynamic phasors are utilized to model both the dc-side and the ac-side of a LCC-HVDC transmission system as well as 6-pulse Graetz bridge, …
-
Control strategies for offshore wind farms based on PMSG wind turbines and HVdc connection with uncontrolled rectifier
… direct-current with line commutated converters (LCC-HVdc). This dissertation proposes the use of diode-based rectifers as a technical alternative to replace the thyristor-based rectifers in an LCC-HVdc link with unidirectional power flow. This alternative shows advantages with regard to lower …
-
Fault detection, discrimination, and recovery in multi-terminal HVDC transmission systems
Multi-terminal high voltage direct current (MT-HVDC) grids enable integration of large-scale renewable energy resources and facilitate flexible bulk power transfer for energy markets extending over political boundaries. Preserving the integrity of MT-HVDC grids during DC faults remains a major …
-
Operating limits and dynamic average-value modelling of VSC-HVDC systems
… operating limits of high-voltage direct-current (HVDC) transmission systems that employ voltage-source converters (VSCs) as their building blocks. This scheme is commonly known as the VSC-HVDC transmission. A simulation-based study is undertaken in which detailed electromagnetic transient (EMT) …
-
Transient overvoltages caused by a monopolar fault on a bipolar dc overhead line with dedicated metallic return
… an overhead bipolar Line Commutated Converter (LCC) HVdc system with a Dedicated Metallic Return (DMR). In HVdc systems with earth return, when a fault occurs, one pole may be lost causing the system to operate in monopolar mode with the ground return. During the fault, overvoltages are induced …
-
Power Electronics Converter Interfaced Power System Emulation Platform Development and Research Demonstration
… modular multilevel converter (MMC) test-bed for HVDC applications.For the versatile power electronics converter based transmission line emulator, the algorithms for emulating transmission line lumped model, traveling wave model, transmission line with integrated compensation devices, and faults …