Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 50 for “"LCL filter"”.
-
Current control of grid connected converter using LCL filter
… a system using a grid connected converter and an LCL filter. The control schemes in question are a PI controller that controls a DC version of the current as well as a PR, an LQR and an LQG controller operating with the AC currents. The controlled current will be analysed in how well the …
-
Design of a grid-tied inverter and LCL filter for photovoltaic application
Submission original under an indefinite embargo labeled 'Open Access'. The submission was exported from vireo on 2025-10-19 without embargo terms
-
Control of a Single-Phase Grid-Connected Voltage Source Inverter with LCL Filter
… voltage source inverter (VSI) with an LCL filter that is used in renewable energy power conditioning applications. There are two main controllers that need to be designed: an external DC-bus voltage controller to balance the power flow coming into the VSI, and an internal current …
-
Regelung von Netzpulsstromrichtern mit LCL-Filter für Antriebe mit kleiner Kapazität im Zwischenkreis
… Antriebssystemen durch verbesserte netzseitige Filtertopologien und den Einsatz von Zwischenkreiskondensatoren mit minimierter Kapazität. Der Schwerpunkt der Arbeit liegt auf den regelungstechnischen Lösungen der Problematiken, die sich durch die Filter und die reduzierten …
-
Estimation Methods for Grid-Voltage Sensorless Control of Converters Equipped with an LCL Filter
… equipped with an inductor-capacitor-inductor (LCL) filter, are widely used in energy production and consumption. The LCL filter effectively attenuates the switching harmonics of the converter; however, a drawback of the filter is its resonating behavior. The resonance can be damped by means of …
-
Active Damping of LCL Filter Resonance for a Single Phase Grid-Connected Distributed Power Generation System
… design and implementation with active damping of LCL filter resonance for a single phase grid-connected Distributed Power Generation (DPGS). The focus of the thesis is to actively damp the LCL filter resonance while keeping inverter control variables well regulated. The mathematical model of the …
-
Improvement of Stability of a Grid-Connected Inverter with an LCL filter by Robust Strong Active Damping and Model Predictive Control
… by an inductive-capacitive-inductive (LCL) filter. A challenge of current control for the VSI is LCL filter resonance near to the control stability boundary, which interacts with the inverter control switching actions and creates the possibility of instability. In general, active …
-
Design and modeling of a power conditioning system for the hybrid fuel-cell/turbine power plant.
… width modulation (SPWM) DC/AC inverter, and an LCL filter. To regulate and stabilize the DC link voltage, DC/DC converter with PI controller is adopted. With three-phase SPWM inverter, both active and reactive power flow can be controlled. Both conventional proportional integral (PI) and the …
-
Investigation of Control Concepts for High-Speed Induction Machine Drives and Grid Side Pulse-Width Modulation Voltage Source Converters
… controlled active front end converter with L-filter in the presence of a parallel thyristor converter is investigated. The design of the LCL-filter components according to the given maximum grid current harmonics (e.g. IEEE-519) is a complex task. So far a precise and clear design procedure …
-
Solar Photovoltaic System Modeling and Control
… error is also designed in this thesis. At last, LCL filter is analyzed and modeled under both steady state and disturbing condition. The effects of LCL filter for improving disturbance rejection capability and dynamic performance of the system is verified.
-
Development of a Versatile Switching Mode Inverter Laboratory Module
… full-bridge driver and a removable LCL filter. These two stages combined make for a laboratory module that allows students to control the parameters in each of the switching techniques and observe the effects on the resulting AC output voltage. Furthermore, the disconnectable LCL …
-
Reliability Enhancing Control Algorithms for Two-Stage Grid-Tied Inverters
… is connected to the grid through the output filter, and the LCL type filter has been commonly used due to its superior performance. The resonance of the LCL filter must be properly damped to enhance the inverter stability. However, the grid-side impedance will lead to the resonant frequency …
-
Study of the Impact of Power Converters Equipped with LC-LCL filters interfacing renewable energy sources to the grid
… distributed generators are equipped with an LC-LCL filter to produce higher power quality while relieving it for reactive power compensation and harmonic elimination. As part of this doctoral thesis, the local control of a distributed generator which is connected to the loads and to the grid via …
-
Power Sharing and Power Quality Improvement in Parallel Connected Power Converters in the Microgrid
… the VSCs need to dampen the high-order LCL filter resonance and to compensate harmonics caused by nonlinear loads. These multi-functional requirements are putting challenges to VSC converter control. To address above issues, this thesis investigates VSC control methods that can …
-
Control of multi-terminal direct current grids
… more details. First, the possibility of using an LCL filter to reduce the conduction losses of the converter is investigated. A detailed method is presented for the design of the LCL filter. Simulation and analytical results are discussed to investigate the impact of the LCL filter on the …
-
Model Predictive Direct Control for Neutral-Point-Clamped Converters
… in the context of a NPC converter with an L-filter-based connection to the grid. Next, a new control strategy, Model Predictive Direct Power Control (MPDPC), is proposed. Both controllers are validated through simulation and experimental results, and are shown to offer a level of steady-state …
-
Weak-Grid Tolerant Control Methods for Voltage-Source Converters
… converter is considered to be equipped with an LCL filter and connected to an inductive grid. The current controller is directly designed in the discrete-time domain. Either the converter or grid current is measured and other states needed by the current controller are estimated using an …
-
Power Control of Virtual Oscillator Controlled Inverters in Microgrids
… the feasible operating region. Moreover, a filter and line parameter design procedure is discussed for non-dispatched inverters to share the power demand proportionally. The local stability of the system with 1-D manifold of equilibria is also established. The existing actual and averaged …
-
Design, analysis and simulation of a new current controller for wind power generation system using proportional plus resonance control.
… loop. Adding a current sensor at the capacitor filter instead of the damping resistor, the proposed two-current loop controller overcomes the instability of the system caused by the LCL filter and minimizes the power loss on the damping resistor (usually 0.8% of rated power). When the impedance …
-
Demonstration of a power conditioning system for grid-connected fuel cell power plant.
… of DC/DC converters, DC/AC inverter, and an LCL filter. The DC/DC converter and DC/AC inverter use switches that operate at high speeds. The use of detailed model with switches will decrease the simulation speed, thus it takes long time to execute time simulations in MATLAB. This thesis …
Page 1 of 3