Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 9 of 9 for “"LEAKAGE FIELD"”.

  1. ΜΙΑ ΣΥΜΒΟΛΗ ΣΤΗΝ ΑΝΑΛΥΣΗ ΤΟΥ ΠΕΔΙΟΥ ΣΚΕΔΑΣΕΩΣ ΚΑΙ ΤΗΣ ΠΥΚΝΟΤΗΤΑΣ ΡΕΥΜΑΤΟΣ ΣΕ ΜΕΤΑΣΧΗΜΑΤΙΣΤΕΣ

    … TO THE MORE PRECISE DETERMINATION OF THE LEAKAGE FIELD, THE CURRENT DENSITY DISTRIBUTION AND THE ELECTROMAGNETIC FORCES ACTING ON THE TRANSFORMER WINDINGS. AN ANALYTICAL METHOD FOR THE DETERMINATIONOF THE ELECTROMAGNETIC MAGNITUDES IS THE TRANSFORMER AREA, WHERE THE LAEKAGEFIELD IS …

    greece Repository record for ΜΙΑ ΣΥΜΒΟΛΗ ΣΤΗΝ ΑΝΑΛΥΣΗ ΤΟΥ ΠΕΔΙΟΥ ΣΚΕΔΑΣΕΩΣ ΚΑΙ ΤΗΣ ΠΥΚΝΟΤΗΤΑΣ ΡΕΥΜΑΤΟΣ ΣΕ ΜΕΤΑΣΧΗΜΑΤΙΣΤΕΣ (opens in a new tab)

  2. Potable Water Leakage Prediction and Detection using Geospatial Analysis

    … spatial interpolation methods to identify leakage areas for further investigation. Analysis of existing geographic information system (GIS) water utility datasets with interpolated hydraulic grade values at sample water pressure points produce manageable survey areas that pinpoint areas …

    etsu Repository record for Potable Water Leakage Prediction and Detection using Geospatial Analysis (opens in a new tab) Download PDF for Potable Water Leakage Prediction and Detection using Geospatial Analysis (opens in a new tab)

  3. Investigation of Slow Release Relays Using Reed Switches

    … relay, and the reed switches are located in the leakage field between these windings. This is the fundamental departure from normal relay practice, in that the flux across the operating gap is only a small fraction of the main flux. A wide range of values of release m.m.f. is normally encountered …

    aston Repository record for Investigation of Slow Release Relays Using Reed Switches (opens in a new tab) Download PDF for Investigation of Slow Release Relays Using Reed Switches (opens in a new tab)

  4. THE DESIGN OF PRIMARY HOLDING MAGNET FOR THE LANL NEUTRON ELECTRIC DIPOLE MOMENT EXPERIMENT

    … 10−27 e·cm (68 % CL). A highly uniform magnetic field is key to achieving this sensitivity for the nEDM measurement by reducing the systematic uncertainties associated with the magnetic field non-uniformity. The B0 coil was designed to achieve a field uniformity of < 0.3 nT·m−1 at a nominal …

    uky-thes Repository record for THE DESIGN OF PRIMARY HOLDING MAGNET FOR THE LANL NEUTRON ELECTRIC DIPOLE MOMENT EXPERIMENT (opens in a new tab)

  5. DEVELOPMENT OF THE COIL VOLUME METHOD FOR TIME-DOMAIN SIMULATION OF INTERNAL FAULTS IN TRANSFORMERS

    … is to identify the components of the transformer leakage field and their interaction during internal faults. The second objective is to develop the Cylindrical and Segmented approaches for segmentation of a faulted coil. The main attraction of the Cylindrical approach is that the sub-coils of the …

    mtu Repository record for DEVELOPMENT OF THE COIL VOLUME METHOD FOR TIME-DOMAIN SIMULATION OF INTERNAL FAULTS IN TRANSFORMERS (opens in a new tab)

  6. Inductive Power Transfer Magnetics for Roads

    … a secondary) to produce and collect the magnetic field. A roadway is a very harsh environment as it is subject to extremes in temperature and vibration. Any roadway IPT system must operate for a long time without maintenance as taking it out of service for maintenance causes disruption. One key …

    auckland-ms Repository record for Inductive Power Transfer Magnetics for Roads (opens in a new tab)

  7. HIGH FLUX DENSITY ROTATIONAL CORE LOSS MEASUREMENTS

    … done under unidirectional pulsating fields, which is sufficient for single-phase transformers and inductors, where the cores are under pulsating fields. However, T-joints of three phase transformers and teeth-roots of rotating machine stator cores are exposed to two-dimensional …

    concordia Download PDF for HIGH FLUX DENSITY ROTATIONAL CORE LOSS MEASUREMENTS (opens in a new tab)

  8. Posouzení vlivu výrobních nesymetrií vinutí transformátorů na zkratové síly

    Práce se zabývá numerickým modelováním zkratových sil v trojfázovém distribučním transformátoru 50 kVA metodou konečných prvků v prostředí Ansys Maxwell 3D. Jsou vytvořeny čtyři simulační modely zachycující často idealizované a zanedbávané znaky skutečných vinutí, konkrétně vliv chladicího kanálu, …

    brno-tech Repository record for Posouzení vlivu výrobních nesymetrií vinutí transformátorů na zkratové síly (opens in a new tab)

  9. Ectomycorrhizal fungi: Their role in nitrogen retention and carbon sequestration in northern coniferous forests

    … C sequestration by EMF mycelium in a large scale field survey was calculated to more than 300 kg C ha-1 y-1. Carbon sequestered by EMF may however be sensitive to additions of N, which typically repress EMF growth. There have been many observations of reduced EMF mycelium production after large …

    lund Repository record for Ectomycorrhizal fungi: Their role in nitrogen retention and carbon sequestration in northern coniferous forests (opens in a new tab) Download PDF for Ectomycorrhizal fungi: Their role in nitrogen retention and carbon sequestration in northern coniferous forests (opens in a new tab)