Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 41 for “"LED array"”.

  1. IMPROVED LED ARRAY REFLECTANCE IMAGING FOR HIGH THROUGHPUT APPLICATIONS

    LED reflectance microscopy is an emerging imaging technique that utilizes multiple illumination patterns to capture high-quality darkfield and differential phase contrast images. However, its acquisition speed and signal to noise ratio are limited by the low backscattering of light off the surface …

    jhu Repository record for IMPROVED LED ARRAY REFLECTANCE IMAGING FOR HIGH THROUGHPUT APPLICATIONS (opens in a new tab)

  2. Development of a Variable-Spectra LED Array for Optimized Plant Development

    … developed using narrow-bandwidth, multi-coloured LEDs. This system was used to test the effects of different light qualities on germination rate, photosynthesis during vegetative growth, and the photosynthetically adaptive nature of several species. It was found that far red light and blue light …

    guelph Repository record for Development of a Variable-Spectra LED Array for Optimized Plant Development (opens in a new tab)

  3. Analytical Methods Development for High-Throughput Photochemisty With Led Arrays

    … construction, and evaluation of a series of LED array photolysis systems for high throughput photochemistry. Three generations of array systems of increasing sophistication are evaluated using calorimetric measurements and potassium tris(oxalato)ferrate(III) chemical actinometry. The results …

    vt Repository record for Analytical Methods Development for High-Throughput Photochemisty With Led Arrays (opens in a new tab)

  4. Žaidimų stalas su RGB šviesos diodų matrica /

    In this work the gaming table with RGB LED array has been created. The system operates using the 32-bit ARM microcontroller. Performed similar devices and technology analysis, principal electric scheme designed and manufactured printed circuit board. Microcontroller software was written in C …

    vilnius Repository record for Žaidimų stalas su RGB šviesos diodų matrica / (opens in a new tab)

  5. LifeLight: Wearable Active Hazard Detection System for Urban/Suburban Nighttime Cyclists

    … found in any competing product is the adaptive LED array. Current safety technologies do not account for variations in ambient lighting and provide little to no protection during times of low visibility and high traffic volume. The LED array is designed to work under any lighting conditions and …

    unr Repository record for LifeLight: Wearable Active Hazard Detection System for Urban/Suburban Nighttime Cyclists (opens in a new tab)

  6. Modeling and Optimization of Flexible Light-Emitting Diode Array for Uniform Light Distribution in Phototherapeutic Applications

    … interactions. Light emitting diodes (LEDs) assembled into arrays have become a popular light source in phototherapy because of their high efficiency and lower costs replacing expensive lasers and bulky, inefficient filtered lamps. However, when illuminating close to the skin for …

    tamu Repository record for Modeling and Optimization of Flexible Light-Emitting Diode Array for Uniform Light Distribution in Phototherapeutic Applications (opens in a new tab)

  7. Fourier series-based optimization of LED angular intensity profiles for displays and backlighting

    … a Fourier series is demonstrated to optimize an LED array for local dimming applications in liquid crystal display backlighting. The same optimization method is also suitable for LED displays in which the Moiré effect must be suppressed during photography with a minimum loss of spatial …

    mcmaster Repository record for Fourier series-based optimization of LED angular intensity profiles for displays and backlighting (opens in a new tab)

  8. NIR light transmission through skin and muscle

    … the visible or middle infrared wavelengths. Knowledge of the transmittance through tissue can help determine the effective light intensities in medical applications. The objective of this thesis is to determine the NIR light transmission through different thicknesses of animal tissue and its …

    njit Repository record for NIR light transmission through skin and muscle (opens in a new tab)

  9. Magnetic field assisted milli-scale robotic assembly machine: an approach to massively parallel swarm robotic automation systems

    … The machine prototype consists of a 16x16 array of electromagnets. The dimensions of the electromagnets are 5mm high with an inner diameter of 1.1mm and outer diameter of 2.5mm. All the electromagnets are driven by a 16x16 array of H-Bridges, and an Arduino microcontroller is used to …

    njit Repository record for Magnetic field assisted milli-scale robotic assembly machine: an approach to massively parallel swarm robotic automation systems (opens in a new tab)

  10. Micro-LED direct writing and structured illumination in automated photolithography

    Monolithic micro-Light Emitting Diode (µ-LED) arrays comprising of pixels on themicro-scale is a rapidly developing technology of interest to researchers through theirhigh efficiency and modulation rate. Coupling with complementary metal-oxide semiconductor (CMOS) electronics allows these devices …

    strathclyde Repository record for Micro-LED direct writing and structured illumination in automated photolithography (opens in a new tab)

  11. III-nitride LEDs and lasers for underwater wireless optical communications

    … delves into the deployment of III-nitride micro-LED and laser-based devices for Underwater Wireless Optical Communications (UWOC), an emerging field with considerable potential for underwater data transfer. UWOC offers a compelling solution owing to the vast bandwidth available in the visible …

    strathclyde Repository record for III-nitride LEDs and lasers for underwater wireless optical communications (opens in a new tab)

  12. Micro-led based optoelectronic tweezers

    … in research. In this thesis, the use of micro-LEDs as a compact illumination source in optoelectronic tweezers systems is explored. The emerging technique of optoelectronic tweezers uses light patterns to generate electric field gradients to trap and manipulate single cells. Micro-LEDs offer an …

    strathclyde Repository record for Micro-led based optoelectronic tweezers (opens in a new tab)

  13. Advanced technologies for spatio-temporal control of neural circuits using optogenetics

    … this possibility combining micro-electrode array (MEA) electrophysiological recordings with a custom two-photon microscope and optogenetic stimulation system based on a ?LED array. This thesis reports on the construction, validation and application of this tool, that was employed in retinal …

    strathclyde Repository record for Advanced technologies for spatio-temporal control of neural circuits using optogenetics (opens in a new tab)

  14. Development and deployment of a novel in situ multiparameter optical sensor for marine and freshwater environments

    … applying two mini spectrometers, a multispectral LED array light source, a photodiode, and custom electronics for interfacing with the optical system and housing the system in a robust enclosure using advanced manufacturing methods. The finalised system and enclosure design was replicated by …

    dcu Download PDF for Development and deployment of a novel in situ multiparameter optical sensor for marine and freshwater environments (opens in a new tab)

  15. CONTINUOUS MEASURES OF MUSCLE BLOOD FLOW DURING ALL-OUT DYNAMIC EXERCISE

    … the experimental cadence. Resistance is controlled by manual Monarch turns and cadence is controlled by dual column LED array. We measured peak oxygen uptake (male = 26.90 ± 5.17 ml O2 kg-1 min-1 vs female = 19.57 ± 2.47 ml O2 kg-1 min-1) and surface EMG to determine the forces necessary to …

    montana-tech Repository record for CONTINUOUS MEASURES OF MUSCLE BLOOD FLOW DURING ALL-OUT DYNAMIC EXERCISE (opens in a new tab)

  16. CONTINUOUS MEASURES OF MUSCLE BLOOD FLOW DURING ALL-OUT DYNAMIC EXERCISE

    … the experimental cadence. Resistance is controlled by manual Monarch turns and cadence is controlled by dual column LED array. We measured peak oxygen uptake (male = 26.90 ± 5.17 ml O2 kg-1 min-1 vs female = 19.57 ± 2.47 ml O2 kg-1 min-1) and surface EMG to determine the forces necessary to …

    montana Repository record for CONTINUOUS MEASURES OF MUSCLE BLOOD FLOW DURING ALL-OUT DYNAMIC EXERCISE (opens in a new tab)

  17. A low gain fine mesh photomultiplier tube for pure CsI

    … pure CsI while in a magnetic field. A prototype array of 16 photomultiplier tubes was built and tested at TRIUMF. This work documents the characterization of the photomultiplier tube as well as University of Montreal’s pre-amplification and shaper electronics. The primary results can be split …

    ubc Repository record for A low gain fine mesh photomultiplier tube for pure CsI (opens in a new tab) Download PDF for A low gain fine mesh photomultiplier tube for pure CsI (opens in a new tab)

  18. Design of a real time optical sensor for continuous blood cell separation

    … theory. The prototype sensor consists of two arrays of light emitting diodes, red and infrared, and photodiodes. The emission wavelength of LEDs are 660 nm and 800 nm. The 800 rim which is in the infrared region is very close to isobestic value for blood. The prototype sensor is mounted on the …

    njit Repository record for Design of a real time optical sensor for continuous blood cell separation (opens in a new tab)

  19. Developments of Gigapixel Microscopy

    … time of the FP platform, sparsely sampled FP, which uses a sparse-sampled mask to filter the captured intensity images, is developed and it reduced the acquisition time by ~ 50%. In addition, the application of sub-sampled Fourier ptychography solved the pixel aliasing problem. …

    uconn-diss Repository record for Developments of Gigapixel Microscopy (opens in a new tab)

  20. High Throughput Platform for the Rapid Stretching of Brain Cells

    … data. Finally, the simple addition of a infrared LED array is used to demonstrate its versatility in high throughput applications beyond mTBI. The device presented in this study is expected to be a valuable tool for carrying out high throughput mechanobiological experiments including identifying a …

    auckland-ms Repository record for High Throughput Platform for the Rapid Stretching of Brain Cells (opens in a new tab)

Page 1 of 3