Predicting drug residue depletion to establish a withdrawal period with data below the limit of quantitation (LOQ)
… levels at or below the limit of quantitation (LOQ) of the analytical method present a special challenge in the estimation of the tolerance limit. Because values observed below the LOQ are thought to be unreliable, they add in an additional source of uncertainty and, if dealt with improperly or …
-
Estimation of an upper tolerance limit for small-samples containing observations below the limit of quantitation
… at a level below the limit of quantitation (LOQ). Because the measurement of the tissue concentration cannot be confidently determined with enough precision, these types of observations are often treated as if they were left censored where the censoring value is equal to the limit of …
-
Brain Topography of Leadership: Neurophysiological Correlates of the Leadership Opinion Questionnaire
… data from the Leadership Opinion Questionnaire (LOQ) assessment survey. Research began with 293 right-handed males, 18 to 26 years-old, who completed the LOQ. Based on their scores, 61 subjects, grouped by the Ohio State Leadership Quadrants, were tested using brain-mapping technology.
-
Nustatymo ribos matavimo būdų skysčių chromatografijoje palyginimas /
… Liquid Chromatography Limit of quantification (LOQ) is perhaps the most important performance characteristic in analytical method validation. In the present work three methods based on the signal-to-noise ratio, linear regression and Eurachem guidelines were compared to estimate the limits of …
-
Analityczne oznaczanie kannabinoidów w surowcach i produktach otrzymanych z konopi za pomocą UHPLC z detektorami UV-VIS i CORONA CAD
… kalibrację, precyzję, dokładność, LOD, LOQ i odporność. Dla DAD zastosowano kalibrację liniową, a dla CAD regresję kwadratową z ważeniem 1/x lub 1/x². Zakres roboczy wynosił od LOQ do 200 lub 250 μg/mL, zależnie od analitu. LOD i LOQ mieściły się odpowiednio w zakresach 1–5 i 1–10 μg/mL. …
-
Oral Fluid Method Validation for Bowling Green State University
… of Detection (LOD) and Limit of Quantitation (LOQ), carryover, interference, stability, and matrix effects. Due to the Covid-19 global pandemic, only accuracy, precision, linearity, and LOD and LOQ were accessed. The validation studies were conducted over five days (not consecutive) with two …
-
An evaluation of a human relations training program for engineers
… namely the Leadership Opinion Questionnaire (LOQ), the Leadership: Employee Orientation and Differentiation Questionnaire (LEAD) and the Profile of Organizational Characteristics (Form-S). The LOQ is a well-established instrument which measures two variables identified as Consideration (C) and …
-
Concept Interview Assignment to Foster Intentional Learning in Nursing Students
… used the Learning Orientation Questionnaire (LOQ), which has demonstrated sound psychometric properties. The Conceptual Model for Successful Intentional Learning was adapted to guide this study. This model is based on neuroscience research on the limbic system (i.e., emotional center of the …
-
Serum Amikacin Concentrations in Dogs With Naturally Occurring Open Wounds Treated With Topical Amikacin in Carboxymethylcellulose Hydrogel
… in each serum sample (limit of quantification, LOQ, of 2.5ug/ml). Eleven dogs were enrolled in the study. Median age was 6.8 years (range, 1.8-12.3 years). Median weight was 20.2kg (range, 15.1-41.1kg). Median volume of amikacin gel administered per wound was 1.45ml (range, 0.1-11ml). Median …
-
Serum Amikacin Concentrations in Dogs With Naturally Occurring Open Wounds Treated With Topical Amikacin in Carboxymethylcellulose Hydrogel
… in each serum sample (limit of quantification, LOQ, of 2.5ug/ml). Eleven dogs were enrolled in the study. Median age was 6.8 years (range, 1.8-12.3 years). Median weight was 20.2kg (range, 15.1-41.1kg). Median volume of amikacin gel administered per wound was 1.45ml (range, 0.1-11ml). Median …
-
Serum Amikacin Concentrations in Dogs With Naturally Occurring Open Wounds Treated With Topical Amikacin in Carboxymethylcellulose Hydrogel
… in each serum sample (limit of quantification, LOQ, of 2.5ug/ml). Eleven dogs were enrolled in the study. Median age was 6.8 years (range, 1.8-12.3 years). Median weight was 20.2kg (range, 15.1-41.1kg). Median volume of amikacin gel administered per wound was 1.45ml (range, 0.1-11ml). Median …
-
Serum Amikacin Concentrations in Dogs With Naturally Occurring Open Wounds Treated With Topical Amikacin in Carboxymethylcellulose Hydrogel
… in each serum sample (limit of quantification, LOQ, of 2.5ug/ml). Eleven dogs were enrolled in the study. Median age was 6.8 years (range, 1.8-12.3 years). Median weight was 20.2kg (range, 15.1-41.1kg). Median volume of amikacin gel administered per wound was 1.45ml (range, 0.1-11ml). Median …
-
Développement de nouvelles stratégies de préparation de l'échantillon et d'analyse pour la recherche de traces de pesticides et de contaminants dans diverses matrices agroalimentaires.
… dans diverses céréales avec des valeurs de LOQ généralement fixées à 10 μg/kg. Une deuxième méthode d’analyse de plus de 220 pesticides et contaminants dans les céréales, les fruits et légumes avec des valeurs de LOQ également fixées à 10 μg/kg pour la quasi-totalité des molécules, a été …
-
Desenvolvimento de métodos analíticos para determinação do gás fosfina
… detecção (LoD) de 0,062 mL e de quantificação (LoQ) de 0,208 mL, em uma faixa analítica de trabalho no intervalo de 0,208 mL até 1,5 mL de fosfina. O segundo foi um método espectrofotométrico baseado na descoloração do azul de metileno. Foram estabelecidas condições experimentais de azul de …
-
Antibody-based detection and quantification of Pectobacterium carotovorum ssp. carotovorum
… (LOD) = 81 CFU/ml; limit of quantitation (LOQ) = 216 CFU/ml) and Pcc LPS (LOD = 23 ng/ml; LOQ = 76 ng/ml) were developed. A preliminary user-friendly dipstick assay was also developed (? 105 CFU/ml). A phage display library was constructed (6.0 x 105 clones/ml), yielding one unique anti-Pcc …
-
Development of an ultrasensitive ELISA for the detection of Mycobacterium tuberculosis antigens: an impossible challenge or a promising feat?
… of detection (LOD) and limit of quantification (LOQ) of the direct-biotinylated ELISA was determined for each antigen: 1) GroES had an LOD of 1.959 ng/mL and an LOQ of 6.531 ng/mL, 2) Mpt32 had an LOD of 1.884 ng/mL and an LOQ of 6.278 ng/mL, and 3) DnaK had an LOD of 6.310 ng/mL and an LOQ of …
-
Hydroxypropylmethylcellulose: A New Matrix for Solid-Surface Room-Temperature Phosphorimetry
… (LOD), and lower limits of quantitation (LOQ) for certain phosphor/heavy-atom combinations since SSRTP signal intensities are stronger. For example, the determination of the analytical figures of merit for a naphthalene/sodium iodide/HPMC system resulted in a calibration sensitivity of …
-
Avaliação da ocorrência de poluentes orgânicos persistentes no sistema estuarino de Laguna, Santa Catarina
… concentrações acima do limite de quantificação (LOQ) e em mais de 10% das amostras. De modo geral, os DDTs (valores de <LOQ a 39,20 ng/g de peso seco) excederam os PCBs (valores de <LOQ a 52,79 ng/g de peso seco) e, por meio da avaliação das concentrações de precursores e metabólitos, os …
-
Development of liquid chromatography with tandem mass spectrometry method for measurement of sepsis biomarkers
… of detection (LOD), limit of quantification (LOQ), and specificity of these two methods were compared. Results: The result highlighted superiority of PRM method developed using the Orbitrap compared to MRM assay using QqQ. MRM method developed using an API 3000 QqQ is limited to monitor …
-
Applications of laser ablation inductively coupled plasma mass spectrometry for monitoring impurities in solid foodstuff
… As, Cd, Hg, and Pb. Quantification limits (LOQ) of 0.56, 0.13, 0.10, 0.10 μg/g were determined for As, Cd, Hg, and Pb respectively with the Nd:YAG laser. Similarly, the excimer laser gave LOQ of 0.063, 0.016, 0.057, 0.006 μg/g. All LOQ were capable of quantifying the impurities below …