Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 14 of 14 for “"LS-APGD"”.

  1. Progress Towards Uranium Isotope Ratio Measurements Directly from Cotton Swipes with the Liquid Sampling – Atmospheric Pressure Glow Discharge (LS-APGD) Ionization Source

    … sampling – atmospheric pressure glow discharge (LS-APGD) ionization source is a novel microplasma ionization source capable of ionizing a diverse set of both inorganic and organic chemical species including, ionic metal constituents as well as ligated metallic species, polyaromatic hydrocarbons …

    clemson Repository record for Progress Towards Uranium Isotope Ratio Measurements Directly from Cotton Swipes with the Liquid Sampling – Atmospheric Pressure Glow Discharge (LS-APGD) Ionization Source (opens in a new tab)

  2. Optimization of the Liquid Sampling-Atmospheric Pressure Glow Discharge for Varied Spectrochemical Applications

    … laboratories. The ideal instrument for metals analysis would be a low-cost, low footprint instrument capable of similar performance to and higher throughput than an ICP. Towards this end, the liquid sampling-atmospheric pressure glow discharge (LS-APGD) was developed. The LS-APGD is a small …

    clemson Repository record for Optimization of the Liquid Sampling-Atmospheric Pressure Glow Discharge for Varied Spectrochemical Applications (opens in a new tab)

  3. Diverse Mass Spectrometric Couplings and Applications of the Liquid Sampling–Atmospheric Pressure Glow Discharge as a Combined Atomic and Molecular Ionization Source

    … sampling – atmospheric pressure glow discharge (LS-APGD). The LS-APGD was initially developed for solution-based trace metal analysis and paired with optical detection systems, but has since been interfaced with a variety of mass spectrometers. Operating at atmospheric pressure, the LS-APGD has …

    clemson Repository record for Diverse Mass Spectrometric Couplings and Applications of the Liquid Sampling–Atmospheric Pressure Glow Discharge as a Combined Atomic and Molecular Ionization Source (opens in a new tab)

  4. DEVELOPMENT OF A MINIATURIZED AMBIENT GLOW DISCHARGE IONIZATION SOURCE AND ITS APPLICATION IN ELEMENTAL AND MOLECULAR ANALYSIS

    … sampling-atmospheric pressure glow discharge (LS-APGD) was first developed as an excitation source for atomic emission spectroscopy, it has been improved upon and demonstrated as an ionization source for elemental mass spectrometry, molecular mass spectrometry, and ambient desorption mass …

    clemson Repository record for DEVELOPMENT OF A MINIATURIZED AMBIENT GLOW DISCHARGE IONIZATION SOURCE AND ITS APPLICATION IN ELEMENTAL AND MOLECULAR ANALYSIS (opens in a new tab)

  5. Development of Solid Sampling Modalities for the Liquid-Sampling Atmospheric Pressure Glow Discharge Microplasma

    … sampling – atmospheric pressure glow discharge (LS-APGD) microplasma that is utilized primarily for solution analysis. The analytical merits of the LS-APGD overlaps with that of direct solid sampling. The LS-APGD provides a multi-faceted approach to analytical instruments by providing a variety …

    clemson Repository record for Development of Solid Sampling Modalities for the Liquid-Sampling Atmospheric Pressure Glow Discharge Microplasma (opens in a new tab)

  6. Interfacing the Liquid Sampling- Atmospheric Pressure Glow Discharge Ion Source with Orbitrap Mass Spectrometers for High Accuracy High Precision Isotope Ratio Measurements of Uranium

    … sampling – atmospheric pressure glow discharge (LS-APGD) with Orbitrap mass spectrometers has led to a potential paradigm shift in the field of high certainty isotope ratio measurements. Since the dawn of the atomic age, mass spectrometry has played a critical role in performing isotope ratio …

    clemson Repository record for Interfacing the Liquid Sampling- Atmospheric Pressure Glow Discharge Ion Source with Orbitrap Mass Spectrometers for High Accuracy High Precision Isotope Ratio Measurements of Uranium (opens in a new tab)

  7. Analytical Evaluation of an Atmospheric Pressure Glow Discharge Microplasma as an Emission Source

    … sampling-atmospheric pressure glow discharge (LS-APGD) microplasma, developed by Marcus and co-workers, is a novel excitation source for atomic emission spectroscopy developed to meet these goals. This emission/ionization source meets the demands needed for field-capable instrumentation by …

    clemson Repository record for Analytical Evaluation of an Atmospheric Pressure Glow Discharge Microplasma as an Emission Source (opens in a new tab)

  8. Evaluation and Optimization of a Liquid-Sampling Atmospheric Pressure Glow Discharge Ionization Source for Diverse Applications in Mass Spectrometry

    … mass spectrometry (TIMS). These instruments also require very high-resolution mass analyzers so isobaric elemental isotopes can be clearly resolved and quantified, typically employing sector field and Fourier transform ion cyclotron resonance (FT-ICR) analyzers. Conversely, large biomolecules …

    clemson Repository record for Evaluation and Optimization of a Liquid-Sampling Atmospheric Pressure Glow Discharge Ionization Source for Diverse Applications in Mass Spectrometry (opens in a new tab)

  9. Liquid Sampling–Atmospheric Pressure Glow Discharge Ionization Source Coupled to an Ultra High Resolution Orbitrap Mass Spectrometer for Diverse Spectrochemical Analysis

    … sampling – atmospheric pressure glow discharge (LS-APGD) coupled to an ultra-high resolution Orbitrap mass spectrometer has demonstrated expanded abilities for the uranium isotope ratios and molecular analysis by adding low polarity polyaromatic hydrocarbons (PAHs) to its already impressive …

    clemson Repository record for Liquid Sampling–Atmospheric Pressure Glow Discharge Ionization Source Coupled to an Ultra High Resolution Orbitrap Mass Spectrometer for Diverse Spectrochemical Analysis (opens in a new tab)

  10. Miniaturization of Chemical Analysis Tools: Micro-Solid Phase Extraction Tips for Protein Extractions and Development of a Miniaturized Glow Discharge Source for Elemental Analysis

    … sampling-atmospheric pressure glow discharge (LS-APGD) as an excitation source for elemental analysis. Determination of proteins in biological matrices is vital for the identification of disease-specific biomarkers. With this in mind, research efforts have grown tremendously for protein …

    clemson Repository record for Miniaturization of Chemical Analysis Tools: Micro-Solid Phase Extraction Tips for Protein Extractions and Development of a Miniaturized Glow Discharge Source for Elemental Analysis (opens in a new tab)

  11. Application of High Resolution Mass Spectrometery to Irradiated UO2 Using Source Reactor Discrimination Methodology

    … isotopic compositions in irradiated materials, enabling the resolution of critical isobaric interferences without extensive chemical processing. In this study, the isobaric interference between 150Nd and 150Sm is addressed to enable quantitative measurement of 150Sm. A previously developed …

    tamu Repository record for Application of High Resolution Mass Spectrometery to Irradiated UO2 Using Source Reactor Discrimination Methodology (opens in a new tab)

  12. Application of High Resolution Mass Spectrometery to Irradiated UO2 Using Source Reactor Discrimination Methodology

    … isotopic compositions in irradiated materials, enabling the resolution of critical isobaric interferences without extensive chemical processing. In this study, the isobaric interference between 150Nd and 150Sm is addressed to enable quantitative measurement of 150Sm. A previously developed …

    tamu Repository record for Application of High Resolution Mass Spectrometery to Irradiated UO2 Using Source Reactor Discrimination Methodology (opens in a new tab)

  13. Application of High Resolution Mass Spectrometery to Irradiated UO2 Using Source Reactor Discrimination Methodology

    … isotopic compositions in irradiated materials, enabling the resolution of critical isobaric interferences without extensive chemical processing. In this study, the isobaric interference between 150Nd and 150Sm is addressed to enable quantitative measurement of 150Sm. A previously developed …

    tamu Repository record for Application of High Resolution Mass Spectrometery to Irradiated UO2 Using Source Reactor Discrimination Methodology (opens in a new tab)