Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 47 for “"LaBr3"”
-
Characterization of LaBr3(Ce) Detectors for Picosecond Lifetime Measurements
… has been a great deal of interest in the use of LaBr3 (Ce) detectors for fast timing measurements. Due to their excellent energy resolution, ≈ 3% at 1MeV, they offer an improved signal to background over BaF2 which has ≈ 9% energy resolution. Many groups are planning arrays of LaBr3 detectors. …
-
Study of LaBr3 (Ce) detector response to high energy helium ions
… is important to understand the response of the LaBr3 scintillator in the presence of heavy ions to provide more accurate measurements of the gamma fields within such a complex radiation environment. A series of Monte-Carlo simulations using MCNP/X version 2.6 have been performed along with a …
-
Characterisation of a LaBr3:LaCl3 Phoswich Array Using 70-230 MeV Protons
… of CALIFA. The prototype consists of four LaBr3(Ce):LaCl3(Ce) phoswich crystals, arranged in a 2x2 array, consisting of 4 cm LaBr3(Ce) and 6 cm LaCl3(Ce). This phoswich array is characterised by using 70-230 MeV protons of well-defined energy, cosmic muons, and simulations. Integral and …
-
Solving the Extremely High Dead Time During Ultra-High-rate Gamma-ray Spectrometry Using a LaBr3(Ce) Detector
… spectrometry is the large dead time. Using a LaBr3(Ce) detector (TRT 0.3 µs, TFT 0.5 µs), with an input count rate of 4.8×10E5 cps, the dead time could be as high as 87%. Such high dead time could significantly reduce the quality of the data collected as a considerable number of counts would …
-
Feasibility Study of a Portable Coupled 3He Detector with LaBr3 Gamma Scintillator for Field Identification and Quantification of Nuclear Material
… consists of a plastic scintillator containing LaBr3 nanoparticles and a polyethylene slab containing four 3He tube detectors. The system was tested via simulation with MCNPX for four Pu samples of known quality and quantity. These samples had masses ranging from 100-300 g of Pu. It was found …
-
A comparison of the use of sodium iodide and lanthanum bromide scintillation crystals for airborne surveys
… and characterization: lanthanum bromide [LaBr3(Ce)] and sodium iodide [NaI(Tl)] scintillation systems. An aerial survey of a uranium mine in the western United States was performed using both NaI(Tl) and LaBr3(Ce) detection systems. Analyses of the survey data were performed with RadAssist …
-
Building a Hybrid Compton Camera System for Improving Medical Imaging Applications
… de-tector as the scatterer layer with a 2” × 2” LaBr3:Ce detector as the absorber. CC2 and CC3 incorporated novel MacroPixel LB-14x25c-SiPM-T scintillation detector assemblies using a va-riety of different physical configurations. CC2 was evaluated for three distinct geometries, utilising a 4 × 1 …
-
Adecuación y desarrollo de métodos de análisis de datos obtenidos mediante espectrometría gamma para la medida de la radiactividad ambiental en tiempo real
… amb detectors d’escintil•lació de NaI (Tl) i LaBr3 (Ce). Les mesures ambientals registrades amb monitors d'espectrometria gamma en temps real no tenen significat radiològic fins que se sotmeten a processos d'adequació. Aquests processos comprenen l'estabilització d'espectres, els calibratges …
-
Μελέτη και βελτιστοποίηση παραμέτρων απόδοσης φωταύγειας κρυσταλλικών σπινθηριστών για χρήση σε ανιχνευτικές διατάξεις ιοντιζουσών ακτινοβολιών υβριδικών συστημάτων ιατρικής απεικόνισης
… scintillators in single-crystal form, LaCl3 and LaBr3 doped with Ce3+, when exposed to ionizing radiations such as X-rays and gamma rays. These two single-crystal scintillators offer high light yield and good energy resolution. The aim of the study is to assess the suitability of these …
-
A compton camera prototype with γ-PET imaging capability: from component evaluations to online tests
… Absorberdetektor wurden monolithische LaBr3:Ce und CeBr3 Szintillatoren (51 × 51 × 30 mm^3) untersucht. Durch ihre stöichometrische Ähnlichkeit versprechen beide Materialien eine vergleichbare Leistungsfähigkeit und folglich auch vergleichbare Szintillationseigenschaften (Lichtausbaute, …
-
MEASUREMENT OF HIGH-ENERGY GAMMA RAYS TO STUDY THE DYNAMICAL DIPOLE EMISSION AND THE ISOSPIN MIXING
… In such experiment an array of large volume LaBr3:Ce detectors was used for the first time. A study of the in-beam performances of such array was carried out, together with a characterization of large volume LaBr3:Ce detectors.
-
Monte Carlo Simulations of Novel Scintillator Detectors and Dosimetry Calculations
… of prototypes for medical imaging, based on LaBr3:Ce scintillation crystals coupled with a position sensitive photomultiplier, have been studied using GEANT4 simulations. Having tested, in the simulation, surface treatments different from the one applied to the crystal used in our …
-
An Analysis of the Scintillation Properties of Several Materials for Radiation Detection
… to 2 other inorganic crystals, NaI:Tl and LaBr3:Ce on the basis of its energy resolution. The energy resolution for several gamma-ray energies were measured and SrI2:Eu3% was found to have an energy resolution of (6.7±0.1)% for the 662 keV photopeak. SrI2:Eu3% shows significant promise for …
-
Ανάπτυξη τεχνολογίας για ραδιολογικό χαρακτηρισμό καταλοίπων με εμπλουτισμό σε φυσικά ραδιονουκλίδια (NORM waste) που προέρχονται από βιομηχανίες πετρελαίου
… spectrometry measurements by using a 1.5x1.5 in. LaBr3(Ce) scintillation detector. Three types of containers for OBM packaging were simulated as volume sources: Metallic Drum, Flexible Intermediate Bulk Container – FIBC, Intermediate Bulk Container – IBC, of known radioactivity and material …
-
Improvement of a detection system for in-vivo Al measurements, and in-vivo Al measurements of a population of miners.
… currently used 4π NaI(Tl) system, and a single LaBr3(Ce)) and a semi-conductor, a single closed-end coaxial HPGe. MDLs for these detectors were found to be 15.85 μgAl/gCa (236.17 μgAl) for the 4π NaI(Tl) system, 56.51 μgAl/gCa (842.0 ugAl) for the HPGe and 98.67 μgAl/gCa (1470.20 μgAl) for the …
-
Improvement of early warning monitoring using gamma spectrometry
… 5000). In this thesis the lanthanum bromide, LaBr3(Ce), detector has been selected as the reference instrument to study the possibility of installing it in early warning networks. The reasons for its choice were its resolution, which improves from 7 % to 3 % at 662 keV, its availability and …
-
Development and calibration of automatic real-time environmental radioactivity monitors using gamma-ray spectrometry
… gamma-ray spectrometry, either with NaI(Tl) or LaBr3(Ce) detectors, which permit the real-time identification and quantification of radioactive isotope content in water and in air. In the thesis, details on general calibration methodologies can be found. The mentioned developments as well as …
-
Détection en temps réel de particules auprès des lasers de puissance
… à base de CdTe et un scintillateur LaBr3 couplé à un photo-détecteur hybride (HPD). Pour la détection des rayons gamma de faible énergie (6,2 keV), nous avons utilisé une photodiode à avalanche (APD) présentant une zone de déplétion épaisse. Ces détecteurs ont été étudiés …
Page 1 of 3