Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 10 of 10 for “"Laboratory Column Tests"”

  1. URBAN PARTICLE AND POLLUTANT CAPTURE VIA STORMWATER FILTER FACILITIES AND THE CONCOMITANT WATER QUALITY AND HYDROLOGICAL BENEFITS

    … media core collection and analysis, and laboratory column tests. Results indicate that bioretention facilities can achieve substantial hydrological benefits through delaying / reducing peak flows and decreasing runoff volume. Bioretention effluents exhibited good water quality for nearly …

    maryland Repository record for URBAN PARTICLE AND POLLUTANT CAPTURE VIA STORMWATER FILTER FACILITIES AND THE CONCOMITANT WATER QUALITY AND HYDROLOGICAL BENEFITS (opens in a new tab)

  2. A methodology to predict long-term leaching potential of metals from Class F fly ash based on short-term laboratory tests

    … behavior of metals from fly ash using short-term laboratory tests data. The objectives of this study were achieved by an experimental phase and a modeling phase. The experimental phase consisted of a series of laboratory column tests on fly ash samples, collected from Hoechst Celanese plant at …

    ttu Repository record for A methodology to predict long-term leaching potential of metals from Class F fly ash based on short-term laboratory tests (opens in a new tab)

  3. Soil physical characteristics related to failure of stormwater biofiltration devices

    … was examined under severe service conditions. Laboratory and field-scale studies were conducted to provide insight into the existing soil characteristics of a poorly operating biofilter facility. Surface double-ring infiltration tests (comprised of three separate setups each) and bore hole …

    alabama Repository record for Soil physical characteristics related to failure of stormwater biofiltration devices (opens in a new tab)

  4. Effect of Tailings Mineralogy and Infiltration Water Chemistry on Arsenic Release From Historic Gold Mine Tailings

    … were characterized and subjected to 29 weeks of column testing, in which each sample was leached with three different input solutions including synthetic rainwater (to simulate uncovered tailings exposed to natural acid rain), synthetic rainwater equilibrated with calcium carbonate (to simulate …

    queens Repository record for Effect of Tailings Mineralogy and Infiltration Water Chemistry on Arsenic Release From Historic Gold Mine Tailings (opens in a new tab)

  5. Treatment of Stormwater Runoff by Geotextile Filters via Suspended Solids Capture

    … In this study, three geotextiles were tested in laboratory column tests with influent suspensions having hydraulic loading rates, total suspended solids (TSS) concentrations, and particle size distributions (PSDs) similar to those reported for urban highway stormwater runoff. After a short …

    maryland Repository record for Treatment of Stormwater Runoff by Geotextile Filters via Suspended Solids Capture (opens in a new tab)

  6. Απομάκρυνση ρυπαντών απο εκχυλίσματα μεταλλευτικών στερεών αποβλήτων με ενεργούς διαπερατούς φραγμούς από ερυθρά ιλυ και ιπταμένη τέφρα

    … two main sets of long-term continuous-upflow laboratory column tests: i) single-metal independent tests of Cu2+ aqueous solutions in to elucidate the individual kinetic processes and the effect of initial metal concentration, pH and pore water velocity, and ii) multi-metal component tests of …

    greece Repository record for Απομάκρυνση ρυπαντών απο εκχυλίσματα μεταλλευτικών στερεών αποβλήτων με ενεργούς διαπερατούς φραγμούς από ερυθρά ιλυ και ιπταμένη τέφρα (opens in a new tab)

  7. Lösungsprozesse und Transport leichtlöslicher Salze in Monodeponien für Rückstände aus der Müllverbrennung

    … leaching of was observed for 25 months. Laboratory column tests and field experiments (test bodies and lysimeters) were performed with municipal solid waste incineration residues. Laboratory columns were irrigated with tap water. Control field experiments were exposed to natural …

    lmu-germany Repository record for Lösungsprozesse und Transport leichtlöslicher Salze in Monodeponien für Rückstände aus der Müllverbrennung (opens in a new tab)

  8. Modelling the transport of iron-based colloids in saturated porous media

    … are presented, and the protocol adopted for column tests of colloidal mobility under different hydrochemical conditions is described: each experiment included a deposition step at constant ionic strength, followed by release steps induced by abrupt changes in porewater chemistry. • Chapter 4. …

    poli-torino Repository record for Modelling the transport of iron-based colloids in saturated porous media (opens in a new tab)

  9. Μελέτη απομάκρυνσης εξασθενούς χρωμίου από το πόσιμο νερό

    … step Testing of Na2S2O4 under Rapid Small Scale Column Tests (RSSCTs) practicing FeOOH as a surface catalyst revealed that a dose of, at least 10 mg S/L Na2S2O4 should be applied in order to ensure the reduction of an initial 100 μg/L Cr(VI) concentration below the upcoming drinking water …

    greece Repository record for Μελέτη απομάκρυνσης εξασθενούς χρωμίου από το πόσιμο νερό (opens in a new tab)

  10. The Acceleration of the Diffusion-Limited Pump-and-Treat Aquifer Remediation with Pulsed Pumping that Generates Deep Sweeps and Vortex Ejections in Dead-End Pores

    … our hypothesis in a series of numerical and laboratory experiments. We considered unwashed and washed media. For unwashed media (Chapter 1) we used as a square pore in the numerical domain and crushed glass (for its negligible sorption capacity) in laboratory column studies. For washed media …

    duke Repository record for The Acceleration of the Diffusion-Limited Pump-and-Treat Aquifer Remediation with Pulsed Pumping that Generates Deep Sweeps and Vortex Ejections in Dead-End Pores (opens in a new tab)