Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 56 for “"Laboratory calibration"”
-
Laboratory calibration of the CS655 soil moisture sensor
Calibration of a frequency domain reflectometer (model CS655, Campbell Scientific, Inc. Logan, UT) is presented using five distinct soil types and three different calibration methods. Frequency domain reflectometers estimate soil water content (SWC) using electromagnetic properties of the …
-
Laboratory calibration of soil moisture, resistivity, and temperature probe - Capacitance probe
<p>Laboratory calibration of soil moisture, resistivity, and temperature probe - Capacitance probe.</p>
-
Soil moisture determination using a multisensor capacitance probe: a laboratory calibration
… using a multisensor capacitance probe: a laboratory calibration</p>
-
Validation of the MOPITT-A instrument through radiative transfer modelling and laboratory calibration
This thesis presents the characterization and calibration of the MOPITT-A instrument which uses the technique of correlation spectroscopy to ensure carbon monoxide in the atmosphere. A theoretical model is developed for the instrument and compared to MOPITT-A measurements collected under controlled …
-
An RNA:DNA-based index of growth in juvenile Atlantic menhaden (Brevoortia tyrannus): laboratory calibration and field assessment
… fish habitat for this species. Based on laboratory growth experiments, an RNA:DNA-based growth model was developed for young-of-the-year menhaden. The temporal response of RNA:DNA to changes in feeding condition was also quantified in the laboratory. Results of these investigations …
-
Venturi Meter Performance When Installed on the Branch of a Tee Junction with Converging Run Flow
… tee junction, valve, or elbow. In such a case, a laboratory calibration may be needed to measure the Venturi meter’s performance under said limitations so that accurate metering is achieved. However, in some cases, laboratory calibration may not be possible.The purpose of this research was to …
-
A technique for detecting auroral plasma oscillations
… having a frequency range of 1 kHz to 1 MHz. Laboratory calibration has produced an input/output response for measuring uniform electric fields with field strengths in the range of approximately 5-15 volts/meter. Theoretical considerations suggest that a turbulent auroral plasma may contain …
-
Development and integration of the NPS middle ultraviolet spectrograph with an extreme ultraviolet spectrograph
… Postgraduate School (NPS) and the Naval Research Laboratory (NRL) are working on a joint research project to develop a technique to determine global ionospheric electron densities from satellite platforms. NPS developed a middle ultraviolet spectrograph with wavelength coverage of 1800 to 3400 A. …
-
The development of electronics for a high-speed imaging particle sizing system
… of near-real-time presentation of reduced data. Laboratory calibration results are also included.</p>
-
Hydrologic monitoring of an integrated low impact development (LID) underdrained stormwater management system
… rainfall events. A sensitivity analysis and laboratory calibration has been performed on the flow measurement system. Field data has been evaluated to determine the hydrologic performance of the LID features. Finally, hydrologic models amenable to compact, underdrained LID sites have been …
-
The Design, Fabrication, and Calibration of a Fiber Filter Spectrometer
… work describes the modeling, fabrication, and calibration of a hyperspectral FFS sensor. The image and spectral quality performance metrics are successfully predicted by the FFS model. The laboratory calibration of the instrument validates that the FIG has no substantial impact on the …
-
Non-invasive measurement of fluvial bedload transport velocity
… method had four components: field demonstration, laboratory calibration, development of an error model to separate the bedload velocity signal from the noise in the data, and use of the method in the field to characterize the spatial distribution of bedload transport velocity. The field …
-
Development of an NPS Middle Ultraviolet Spectrograph (MUSTANG) electronic interface package.
… MUSTANG has flown along with a Naval Research Laboratory (NRL) instrument on a NASA sounding rocket experiment, and is scheduled to fly on two more sounding rockets prior to integration on an Air Force satellite. Data from these experiments will test a new technique for measuring global …
-
Evaluation of an airborne optical remote sensing system and operational pre-processing methods
… of any sensor are normally obtained by laboratory calibration. Several experiments were conducted to investigate and enhance knowledge of the performance of the CASI-2. The results suggested that wavelength calibration could reveal systematic optical distortion due to the ‘optical smile’ …
-
Modular computer programming for the reduction of calibration data from internal strain gage balances
… and space vehicles during wind tunnel testing. A laboratory calibration of the strain gage balance furnishes data from which equations are derived to represent the response of the balance to the loads which are likely to be exerted on it during testing. The data reduction method developed for …
-
Time domain reflectometry waveform analysis with second order bounded mean oscillation
… (BMO) operator. Numerical analysis and laboratory calibration tests show that the second order BMO can return reasonable results compared with tangent line methods and AWIGF. Second order BMO analysis also performs well for some challenging waveforms. The second order BMO method is not …
-
The Investigation of a Tin Oxide-Based MEMS Sensor for Measurement of Nitrogen Oxides in Aircraft Engine Exhaust
… with its supporting equipment. Tests, and calibrations were performed and evaluations made on the MEMS sensor, and are discussed in three parts: laboratory calibration and evaluation, off-engine installation and performance, and on-engine instillation and performance.</p> <p>The MEMS device …
-
Contribuição para uma metodologia de desenvolvimento de referências de tensão contínuas programáveis
… references initially used as standards for laboratory equipment calibration consisted of high-cost units which included Clark cells, Weston cells and some types of batteries with restrictive requirements on operation conditions such as temperature controlled.Alternative to the above devices …
-
Venturi Flowmeter Performance Installed Downstream of the Branch of a Tee Junction
… is installed on the branch of a tee. Physical laboratory data was obtained for a 6-in. Venturi in a straight-line, followed by installation on the branch of a tee at zero pipe diameters and five pipe diameters downstream. CFD modeling was then used. Results show the flow rate measurement was …
-
Reliable Gait Analysis with Context-Aware Wearable Sensor Systems
… for estimating key gait parameters outside the laboratory, their accuracy is often affected by sensor noise, drift, activity-dependent movement patterns, and changes in sensor response over time. These challenges limit their practical use in real-world settings, where continuous ground-truth …
Page 1 of 3