Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 142 for “"Laboratory prototype"”

  1. Design of an interleaved PWM rectifier for AC locomotives and implementation of its laboratory prototype

    This research work is devoted to the design, and prototype implementation of a single-phase, unity power factor, Pulse Width Modulated (PWM) Rectifier for use in traction converters of AC locomotives. The PWM Active Rectifier is supplied from a front-end transformer, with two isolated secondary …

    metu Repository record for Design of an interleaved PWM rectifier for AC locomotives and implementation of its laboratory prototype (opens in a new tab)

  2. Analysis and design of an edge-technique-based Doppler wind lidar: practical assessment of a laboratory prototype

    … the design, implementation and assessment of a laboratory prototype based on the edge-technique. The objective of this development is to assess in convenient conditions the implementation of the selected detection technique. This preliminary assembly also permits to characterize and adjust the …

    barcelona Repository record for Analysis and design of an edge-technique-based Doppler wind lidar: practical assessment of a laboratory prototype (opens in a new tab)

  3. Development of an original laboratory prototype for a field tritium detector containing a PEM electrolyzer mounted in series with a gas proportional counter

    … avoid expensive sampling operations as well as laboratory analysis. They also facilitate real time measurement, and decrease the risk to health and cost of long term monitoring. Our research project, developed in three parts, consisted in building a laboratory prototype for a field instrument …

    clemson Repository record for Development of an original laboratory prototype for a field tritium detector containing a PEM electrolyzer mounted in series with a gas proportional counter (opens in a new tab)

  4. COMMON MODE VOLTAGE ELIMINATION IN THREE-PHASE FOUR-LEG INVERTERS UTILIZING PULSE DENSITY MODULATION

    … was analyzed using computer simulations and a laboratory prototype, utilizing SiC switching devices, was designed to validate the model. The physics-based model of the proposed control system was converted to Verilog, a hardware description language (HDL) utilizing MATLAB HDL coder in order to …

    nps Repository record for COMMON MODE VOLTAGE ELIMINATION IN THREE-PHASE FOUR-LEG INVERTERS UTILIZING PULSE DENSITY MODULATION (opens in a new tab)

  5. A Utility-Scale Deployment Project of Behind-the-Meter Energy Storage for Use in Ancillary Services, Energy Resiliency, Grid Infrastructure Investment Deferment, and Demand-Response Integration

    … design was prepared for a ResBESS unit, a laboratory prototype of a single such storage system was constructed, and an alpha prototype is now being installed in a field demonstration project in Milwaukie, Oregon within PGE's service territory. The motivations, design constraints, and design …

    portland-state Repository record for A Utility-Scale Deployment Project of Behind-the-Meter Energy Storage for Use in Ancillary Services, Energy Resiliency, Grid Infrastructure Investment Deferment, and Demand-Response Integration (opens in a new tab)

  6. AN ULTRASONIC LINKAGE SYSTEM FOR A MASTER-SLAVE TRACTOR GUIDANCE SYSTEM

    … of a skillfull worker in agriculture. A laboratory prototype of the linkage system was constructed and tested which confirmed the feasibility of employing the proposed system in a master-slave tractor guidance system.

    sask Repository record for AN ULTRASONIC LINKAGE SYSTEM FOR A MASTER-SLAVE TRACTOR GUIDANCE SYSTEM (opens in a new tab)

  7. Single-Stage Isolated Bidirectional Modular Multilevel Converters for Medium-Voltage DC and AC Ports

    … Switching simulations agree with the model, a laboratory prototype confirms bidirectional operation and power reversal at 600 to 800V DC, and simulated 10 kV designs for 480V and 208V buses show the converter at the scale for which it is intended. Part II treats the MVAC-port AC–DC MMC with …

    calgary Repository record for Single-Stage Isolated Bidirectional Modular Multilevel Converters for Medium-Voltage DC and AC Ports (opens in a new tab)

  8. Design, Analysis and Implementation of New Durable Streetlighting LED Driver Topology

    … and experimental results based on a 200 W laboratory prototype are presented to verify the effectiveness of the design and control systems. The laboratory prototype provides the maximum efficiency of 94.6%, power factor greater than 0.98 at full-load, and below 15% output current ripples.

    alberta Repository record for Design, Analysis and Implementation of New Durable Streetlighting LED Driver Topology (opens in a new tab)

  9. Control de un rectificador elevador de medio puente con alto factor de potencia usando la red neuronal NARMA-L2

    … of a 100 W, 120 V input and 450 V output laboratory prototype, which operates with an equalizer circuit that reduces the voltage imbalance present in the two output capacitors of the plant.

    udistrital Repository record for Control de un rectificador elevador de medio puente con alto factor de potencia usando la red neuronal NARMA-L2 (opens in a new tab)

  10. Stead-State and Small-Signal Modeling of Power-Stage of PWM Z-Source Converter

    … PWM Z-source dc-dc converter is considered. A laboratory prototype is built and the theoretical analysis is in good agreement with the experimental results.</p><p>Ac small-signal modeling of pulse-width modulated (PWM) Z-source converter in continuous conduction mode (CCM) by circuit-averaging …

    ohiolink Repository record for Stead-State and Small-Signal Modeling of Power-Stage of PWM Z-Source Converter (opens in a new tab)

  11. Microwave Intra-Building Transmission Using Spread Spectrum

    … associated with the construction of a laboratory prototype and a compact microstrip prototype are presented and documented. Propagation profiles associated with indoor propagation sites show that average attenuation is typically 2 dB per meter. A discussion of direct-sequence …

    marquette Repository record for Microwave Intra-Building Transmission Using Spread Spectrum (opens in a new tab)

  12. Análise de operação de um retificador trifásico utilizando a técnica de controle de um ciclo

    … and the practical results were verified using a laboratory prototype.

    brazil-ufrn Repository record for Análise de operação de um retificador trifásico utilizando a técnica de controle de um ciclo (opens in a new tab)

  13. Automatic classification of wooden cabinet doors using computer vision

    … classification method. The system exists as a laboratory prototype, and has been successfully tested with a large number of samples.

    vt Repository record for Automatic classification of wooden cabinet doors using computer vision (opens in a new tab)

  14. Design and implementation of thyristor switched shunt capacitors

    … by carrying out experimental work on two prototypes implemented within the scope of this research work, one is a wye-connected laboratory prototype and the other is a delta-connected application prototype integrated to some of the SVCs existing in Turkish Coal Enterprise s Plants. The …

    metu Repository record for Design and implementation of thyristor switched shunt capacitors (opens in a new tab)

  15. Design And Implementation Of Co-Operative Control Strategy For Hybrid AC/DC Microgrids

    … control, and 2) Development of a four bus laboratory prototype of an AC microgrid system. At first, a distributed cooperative control (DCC) for a DC microgrid considering the state-of-charge (SoC) of the batteries in a typical plug-in-electric-vehicle (PEV) is developed. In DC microgrids, …

    nodak Repository record for Design And Implementation Of Co-Operative Control Strategy For Hybrid AC/DC Microgrids (opens in a new tab)

  16. Pole -mounted sonar vibration prediction using CMAC neural networks

    … by simulation and verified with a real-time laboratory prototype, Analytical bounds of the learning rate of a CMAC neural network are derived which guarantee convergence of the weight vector in the mean. Both simulation and experimental results indicate the CMAC neural network is an effective …

    unh-thes Repository record for Pole -mounted sonar vibration prediction using CMAC neural networks (opens in a new tab)

  17. Z-source, full bridge DC/DC converter

    … the converter and controller are both tested in laboratory prototype.

    metu Repository record for Z-source, full bridge DC/DC converter (opens in a new tab)

  18. A three phase all sic PWM rectifier for industry applications

    … be designed by using SiC Power MOSFETs and its laboratory prototype will then be implemented. The topology of the PWM rectifier is the three phase full bridge topology to convert three phase 400 V AC line-to-line voltage to desirable voltage levels between 500V and 1000V. The PWM Rectifier has …

    metu Repository record for A three phase all sic PWM rectifier for industry applications (opens in a new tab)

  19. A transmission line DC de-icer using a single-arm modular multilevel converter

    … by EMT simulation models. Then, a scaled-down laboratory prototype is developed to validate the performance of the SAMMC rectifier and the harmonics suppression controller.

    manitoba Repository record for A transmission line DC de-icer using a single-arm modular multilevel converter (opens in a new tab)

  20. A MAXIMUM POWER POINT TRACKING TECHNIQUE FOR SINGLE-PHASE PHOTOVOLTAIC SYSTEMS WITH REDUCED DC-LINK CAPACITOR

    … in MATLAB Simulink and implemented in a laboratory prototype using the Digital Signal Processing (DSP)-based microcontroller, TMS320F28035.

    houston Repository record for A MAXIMUM POWER POINT TRACKING TECHNIQUE FOR SINGLE-PHASE PHOTOVOLTAIC SYSTEMS WITH REDUCED DC-LINK CAPACITOR (opens in a new tab)

Page 1 of 8