Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 72 for “"Lap Splice"”.

  1. Retrofit of deficient lap splice with post-installed anchors

    … for efficient retrofit solutions, with deficient lap splices being one of many research areas. A possible method to increase the capacity of deficient lap splices is to use post-installed undercut anchors. These anchors function as active confinement in the splice region, potentially allowing …

    texas Repository record for Retrofit of deficient lap splice with post-installed anchors (opens in a new tab)

  2. LAP SPLICE BEHAVIOR IN REINFORCED CONCRETE AT ELEVATED TEMPERATURES

    … that do not represent the stress conditions in a lap splice. This report summarizes observations from tests of 57 small-scale prisms with lap-spliced 16 mm (No. 5) bars and eight large-scale beams with a cross section of 330 by 460 mm (13 by 18 in.) and a length of 14 ft (4.27 m) with lap-spliced …

    ku Repository record for LAP SPLICE BEHAVIOR IN REINFORCED CONCRETE AT ELEVATED TEMPERATURES (opens in a new tab)

  3. Bar development and tension lap splice of high-strength reinforcing steel

    … In particular, bar development and tension lap splice provisions of high-strength reinforcement should be studied, and the serviceability performance in terms of crack control must be evaluated. There is limited data on the serviceability performance of beams with high-strength rebar using …

    texas Repository record for Bar development and tension lap splice of high-strength reinforcing steel (opens in a new tab)

  4. Low frequency ultrasonic nondestructive inspection of aluminum/adhesive fuselage lap splice

    <p>The Federal Aviation Administration's (FAA) Center for Aviation Systems Reliability (CASR), located at Iowa State University (ISU), was established in 1990 in response to the Aviation Safety Act (Public Law 100-591) of 1988. The Aviation Safety Act, created primarily as the result of an …

    iastate Repository record for Low frequency ultrasonic nondestructive inspection of aluminum/adhesive fuselage lap splice (opens in a new tab)

  5. Non-Contact Lap-Splice Design with Ultra-High-Performance-Concrete for Seismic Buildings

    … explores a controllable slippage mechanism in lap-splice configurations of monolithic ultra-high performance concrete (UHPC) members to regulate the location and capacity of plastic hinges in concrete building frames. UHPC's superior tensile, compressive, and bond strengths, compared to normal …

    ucf Repository record for Non-Contact Lap-Splice Design with Ultra-High-Performance-Concrete for Seismic Buildings (opens in a new tab)

  6. Lap Splice Development Length of Rebar in Stabilized Hollow Interlocking Compressed Earth Blocks

    … the tensile performance of unconfined lap splices in specimens constructed from interlocking compressed earth block (ICEB) units. All lap splice specimens were constructed from hollow ICEB half units with one side grouting channel. ICEB units used in this research were exclusively …

    calpoly Repository record for Lap Splice Development Length of Rebar in Stabilized Hollow Interlocking Compressed Earth Blocks (opens in a new tab)

  7. Performance of large size reinforced concrete beams containing a lap splice subjected to fatigue loads

    … loading of reinforced concrete beams containing lap splices. The knowledge acquired from this research has led to recommendations for changes in how seismic and static loading of lap splices are handled. For splices subjected to high cycle low stress load patterns (fatigue loading) current design …

    sask Repository record for Performance of large size reinforced concrete beams containing a lap splice subjected to fatigue loads (opens in a new tab)

  8. Lap splice in glass fiber reinforced polymer‐reinforced concrete rectangular columns subjected to cyclic‐reversed loads

    … the experimental results of nine full-scale lap spliced glass-fiber reinforced polymer (GFRP) reinforced concrete (RC) columns, and one additional reference steel-RC column with lap splices, under axial and cyclic-reversed loads. The test parameters included type of reinforcement, lap splice …

    manitoba Repository record for Lap splice in glass fiber reinforced polymer‐reinforced concrete rectangular columns subjected to cyclic‐reversed loads (opens in a new tab)

  9. Autoclaved aerated concrete (AAC) masonry : lap-splice provisions and nominal capacity for interface shear transfer between grout and AAC

    … Code. Those provisions include the design of lap splices, and equations for the nominal capacity in interface shear transfer between grout and AAC. The provisions for lap splices are an extension of the provisions for concrete or clay masonry, modified to neglect the contribution of AAC to …

    texas Repository record for Autoclaved aerated concrete (AAC) masonry : lap-splice provisions and nominal capacity for interface shear transfer between grout and AAC (opens in a new tab)

  10. Splice tests of plain steel bars in concrete

    Fifteen splice specimens reinforced with plain steel bars, including three specimens instrumented with both steel and concrete strain gauges, were tested under monotonically applied four-point loading to develop a database of reliable bond test results and contribute to the development of a …

    sask Repository record for Splice tests of plain steel bars in concrete (opens in a new tab)

  11. The Effect of Splice Length and Distance between Lapped Reinforcing Bars in Concrete Block Specimens

    The tensile resistance of No. 15 lap spliced reinforcing bars with varying transverse spacing and lap splice length was evaluated in full-scale concrete block wall splice specimens. The range of the transverse spacing between bars was limited to that which allowed the bars to remain within the same …

    sask Repository record for The Effect of Splice Length and Distance between Lapped Reinforcing Bars in Concrete Block Specimens (opens in a new tab)

  12. Compression Lap Splices of Straight Bars and Compression Development of Headed and Hooked Bars in Beam-Column Joints

    … 318-19 Building Code provisions for compression lap splices and for headed and hooked bar development in special moment frame (SMF) joints were evaluated against databases of test results. Recommendations are made for simplifying and improving code requirements.Compression lap splice length …

    ku Repository record for Compression Lap Splices of Straight Bars and Compression Development of Headed and Hooked Bars in Beam-Column Joints (opens in a new tab)

  13. Bond of Corroded Reinforcement in Partial Depth Repairs in Reinforced Concrete Elements

    … Thirty-six beam-end specimens and twenty-four lap splice beams were cast and tested under static loading. The beam-end dimensions were 600 mm in length, 500 mm in height and 250 mm in width and reinforced with 20M bar. The test variables considered for the beam-end specimens were: four …

    waterloo Repository record for Bond of Corroded Reinforcement in Partial Depth Repairs in Reinforced Concrete Elements (opens in a new tab)

  14. Seismic Rehabilitation of RC Structural Walls

    … codes may have deficient shear reinforcement and lap splice detailing. Lap splices at the bottom of the walls were designed in compression with anchorage length of 24-bar diameter. When the structural wall is subjected to lateral loads during a major seismic event, the lap splice is in the zone of …

    mcmaster Repository record for Seismic Rehabilitation of RC Structural Walls (opens in a new tab)

  15. High-Strength Reinforcing Bars (HSRB) and TMS 402: A First Study on Grade 80 (550 MPa) Bars

    … was followed by an experimental study of lap-splice tests for Grade 80 ASTM A615 and ASTM A706 reinforcing deformed bars. The experimental program included twenty-two contact lap-splice experiments in concrete and clay brick masonry, with test variables being the bar size, the lap-splice …

    houston Repository record for High-Strength Reinforcing Bars (HSRB) and TMS 402: A First Study on Grade 80 (550 MPa) Bars (opens in a new tab)

  16. Impact of design variables on seismic fragility of bridges in Georgia

    … assessment of the seismic detailing and lap splice requirements specified in the Bridge and Structure Design Manual (Georgia Department of Transportation) and AASTHO LRFD Design Specifications, Probabilistic methods are used to determine the expected performance of different multi-span …

    gatech Repository record for Impact of design variables on seismic fragility of bridges in Georgia (opens in a new tab)

  17. A Design Approach for Seismic Retrofit of Circular Bridge Columns With Lap Splices

    … of the offset orientation of the bars in the lap splice. However, due to irregularities in the reinforcement details for the field columns the correlation was not obvious. Therefore, a laboratory investigation was undertaken in order to study the optimal amount of lateral confinement necessary …

    uiuc Repository record for A Design Approach for Seismic Retrofit of Circular Bridge Columns With Lap Splices (opens in a new tab)

  18. The engineering of construction specifications for externally bonded FRP composites

    … systems: fiber misalignment, comer radius, and lap splice length. Based on both experimental and theoretical investigations, the main contribution of this work is the development of recommendations on fiber misalignment limit, minimum comer radius, lap splice length to be used as guidance in the …

    must-thes Repository record for The engineering of construction specifications for externally bonded FRP composites (opens in a new tab)

  19. Roadmap for the Use of High Strength Steel in Structural Masonry

    … program of twenty-two direct-tension lap-splice tests on concrete and clay-brick masonry panels with No. 5 and No. 7 Grade 80 bars; after validation against those tests, the models extended the data set through a parametric study of bar sizes, masonry strengths, and grade factors. …

    houston Repository record for Roadmap for the Use of High Strength Steel in Structural Masonry (opens in a new tab) Embargoed until 2028-08-01

  20. Development of Lambda Factors for Masonry Design with Lightweight Grout

    … tests, diagonal tensile strength tests, and lap splice tests. Two types of lightweight aggregates, expanded clay aggregates (EC) and expanded slate (ES) aggregates, are separately used to make the lightweight grout mixes. Firstly, the appropriate mix designs are obtained through a number of …

    clemson Repository record for Development of Lambda Factors for Masonry Design with Lightweight Grout (opens in a new tab)

Page 1 of 4