Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 75 for “"Lap splices"”.

  1. Performance of Reinforced Concrete Column Lap Splices

    Cantilevered reinforced concrete columns with a lap splice of the longitudinal reinforcement near the base can induce high moment demands on the splice region when lateral loads are present on the structure. Code design specifications typically require a conservative splice length to account for …

    tamu Repository record for Performance of Reinforced Concrete Column Lap Splices (opens in a new tab)

  2. Non-Contact Lap Splices in Dissimilar Concretes

    Non-contact lap splices placed within a single concrete placement are often used and have been studied in previous research projects. However, non-contact lap splices used with each bar in a different concrete placement such that there is a cold joint between the bars, have not been investigated. …

    vt Repository record for Non-Contact Lap Splices in Dissimilar Concretes (opens in a new tab)

  3. Seismic behavior of bridge pier column lap splices

    … of concrete bridge columns have resulted in collapse or severe damage of a number of California bridges in recent moderate earth-quakes. In general, these bridges were designed prior to the new seismic design methods which were implemented in the mid-seventies. Bridges constructed in accordance …

    uiuc Repository record for Seismic behavior of bridge pier column lap splices (opens in a new tab)

  4. Confinement Limits For Tensile Lap Splices Under Static Loading

    ABSTRACT In tension lap splices, the benefit provided to the lap by stirrups placed to intercept cracking due to bond splitting action is recognized by the American Concrete Institute (ACI 318-89) and the design recommendations of the ACI Committee 408, on which the American code provisions are …

    sask Repository record for Confinement Limits For Tensile Lap Splices Under Static Loading (opens in a new tab)

  5. Hooked Bar Anchorages and their Use in Noncontact Lap Splices

    Lap splices are used in reinforced concrete structures to transfer tension forces across discontinuous reinforcing bars to allow for continuity of load path in structural elements. Lap splices of straight reinforcing bars present a number of disadvantages when used in connections of large precast …

    vt Repository record for Hooked Bar Anchorages and their Use in Noncontact Lap Splices (opens in a new tab)

  6. Performance of tension lap splices with MMFX high strength reinforcing bars

    … of 80 ksi and 75 ksi. Limited data exists for splices failing at bar stresses greater than 75-80 ksi, and no data exists for splices failing at bar stresses greater than 120 ksi — a stress attainable by MMFX reinforcement. To determine the adequacy of the development length equations in the ACI …

    texas Repository record for Performance of tension lap splices with MMFX high strength reinforcing bars (opens in a new tab) Restricted access

  7. High cycle (fatigue) resistance of reinforced concrete beams with lap splices

    … for reinforced concrete beams containing lap splices has been mainly aimed at preventing failures due to static (monotonic) loading, or low cycle, high intensity (seismic) loading. However, little consideration has been given in these standards or in previous research to the performance of …

    sask Repository record for High cycle (fatigue) resistance of reinforced concrete beams with lap splices (opens in a new tab)

  8. Non-linear modeling parameters for reinforced concrete columns with inadequate lap splices

    … failure. A database of 51 tests on columns with lap-spliced longitudinal reinforcement was assembled. Strength and deformation capacities were extracted from the test data and used to evaluate the splice failure triggers of ASCE/SEI 41-13. Deformation capacities of columns sustaining splice …

    texas Repository record for Non-linear modeling parameters for reinforced concrete columns with inadequate lap splices (opens in a new tab)

  9. The anchorage behavior of headed reinforcement in CCT nodes and lap splices

    … studied using full scale tests of CCT nodes and lap splices. The mechanics of the anchorage behavior were observed and recorded to evaluate the manner in which the capacity of a headed bar is developed. The measured data were used to evaluate existing models of headed reinforcement anchorage as …

    texas Repository record for The anchorage behavior of headed reinforcement in CCT nodes and lap splices (opens in a new tab)

  10. Effectiveness of Alternative Reinforcing Strategies for Non-Contact Hooked Bar Lap Splices

    … concrete. The pieces of concrete are joined by a lap splice which consists of longitudinal steel sticking out of each precast element and overlapped over the minimum required development length. State departments of transportation find it desirable to make the width of closure joints short. To …

    vt Repository record for Effectiveness of Alternative Reinforcing Strategies for Non-Contact Hooked Bar Lap Splices (opens in a new tab)

  11. Non-Contact Lap Splices in Geometrically Dissimilar Bridge Column to Drilled Shaft Connections

    Contact lap splices are widely used for the construction of reinforced concrete structures. But, it is often required to provide a reinforcing steel splicing arrangement with non-contact lap splices due to the limitation of internal space or geometric irregularity for the connection of non-circular …

    houston Repository record for Non-Contact Lap Splices in Geometrically Dissimilar Bridge Column to Drilled Shaft Connections (opens in a new tab)

  12. Evaluation of Mitigative Techniques for Non-Contact Lap Splices in Concrete Block Construction

    … on average, the reinforcing bars in non-contact lap splices, where the lapped bars are located in adjacent cells, only develop 71% of the tensile resistance of spliced bars which are in contact. An experimental program was therefore initiated to design and evaluate remedial measures which can …

    sask Repository record for Evaluation of Mitigative Techniques for Non-Contact Lap Splices in Concrete Block Construction (opens in a new tab)

  13. Evaluation of contact and non-contact lap splices in concrete block masonry specimens

    … tensile resistance of contact and non-contact lap spliced bars in reinforced concrete block masonry using double pullout and wall splice specimens. A total of 32 specimens were tested, consisting of an equal number of double pullout specimens and full-scale wall splice specimens. Both specimen …

    sask Repository record for Evaluation of contact and non-contact lap splices in concrete block masonry specimens (opens in a new tab)

  14. A Design Approach for Seismic Retrofit of Circular Bridge Columns With Lap Splices

    … of the offset orientation of the bars in the lap splice. However, due to irregularities in the reinforcement details for the field columns the correlation was not obvious. Therefore, a laboratory investigation was undertaken in order to study the optimal amount of lateral confinement necessary …

    uiuc Repository record for A Design Approach for Seismic Retrofit of Circular Bridge Columns With Lap Splices (opens in a new tab)

  15. Numerical investigation of bond deterioration in ASR-affected reinforced concrete beams with lap splices

    … bond degradation—especially in regions with lap splices, where structural continuity depends entirely on effective bond. This thesis addresses the need for improved characterization of bond behavior in ASR-affected reinforced concrete beams with spliced bars. First, existing bond- slip models …

    texas Repository record for Numerical investigation of bond deterioration in ASR-affected reinforced concrete beams with lap splices (opens in a new tab)

  16. Effects from Alkali-Silica Reacton and Delayed Ettringite Formation on Reinforced Concrete Column Lap Splices

    … performance of the longitudinal reinforcement lap splice in deteriorated concrete columns is the focus in this research. This thesis presents the results from the deterioration of large-scale specimens constructed and placed in an environment susceptible to ASR/DEF deterioration, the …

    tamu Repository record for Effects from Alkali-Silica Reacton and Delayed Ettringite Formation on Reinforced Concrete Column Lap Splices (opens in a new tab)

Page 1 of 4