Evaluation of the Kipp and Zonen large aperture scintillometer for estimation of sensible heat flux over irrigated and non-irrigated fields in southeastern Colorado
… to assess the performance of the Kipp and Zonen Large Aperture Scintillometer (LAS; Delft, Netherlands) to predict surface sensible heat flux (H). The LAS was introduced approximately 30 years ago and has been marketed as an indirect tool for the estimation of vegetation evapotranspiration (ET). …
-
Measurement techniques used to determine atmospheric structure parameter
… Optical Profiler (PROPS), a Scintec BLS-900 Large Aperture Scintillometer (LAS) and a Kipp & Zonen (K&Z) LAS system. The testing facility at Kennedy Space Center was chosen for its controlled airspace and 5km precision-leveled runway.
-
Estimativa de fluxo de calor sensível com suporte de cintilometria – estudo de caso : Cidade Universitária - Ilha do Fundão/RJ
The large aperture scintillometer (CinLA) is an optical device used to estimate averaged sensible heat fluxes (H) from fluctuations in the refractive index of the turbulent atmosphere in a light beam spread between a transmitter and a receiver. The present dissertation proposes to study the …
-
Understanding the Role of Vegetation Dynamics and Anthropogenic induced Changes on the Terrestrial Water Cycle
… using ecosystem-scale eddy covariance and large aperture scintillometer observations. Our results indicated that the monthly precipitation and seasonal vegetation characteristics such as leaf area index, root length, and stomatal resistance are the main factors influencing ecosystem land …
-
Total evaporation estimation from sugarcane using the scintillation technique.
… of 1 year. The study was performed using a Large Aperture Scintillometer to measure sensible heat flux, whilst all other energy balance components, as well as rainfall, soil moisture and other climatic data were obtained using standard methods. Total evaporation was estimated from latent …
-
Characterizing Atmospheric Turbulence with Conventional and Plenoptic approaches
… being able to characterize it effectively. A scintillometer measures the scintillation in the intensity of a light source to determine the strength of current turbulence conditions. Thermal fluctuation measurements can also be used to derive the strength of atmospheric turbulence. Experimental …
-
Lysimetric evaluation of eddy covariance and scintillometer systems for the Texas High Plains
… accurate method for crop water use measurements, large precision weighing lysimeters are expensive to build and operate. Alternatively, other measurement systems such as eddy covariance (EC) and scintillometry are being used to estimate crop water use. However, due to numerous explicit and …
-
Conception réalisation et mise en oeuvre d'un scintillomètre : influence de la vapeur d'eau dans la bande 940nm
… d'émission de certains scintillomètres LAS (Large Aperture Scintillometer). Au début de ma thèse, un prototype de scintillomètre, type LAS, a été conçu de façon à maitriser complètement la technologie : partie optique électronique et le traitement du signal reçu. Celui-ci a ensuite été …
-
The long-term measurement of total evaporation over Acacia mearnsii using large aperture scintillometry
A large aperture scintillometer (LAS) was operated continuously over a distance of 575 m from 19 August 2006 to 29 September 2007 in the South African KwaZulu-Natal midlands mistbelt area over Wattle (Acacia mearnsii). The LAS measurements of the structure parameter of the refractive index of air ( …
-
Eddy Covariance in a Tallgrass Prairie: energy balance closure, water and carbon budgets, and shrub expansion
… lowland [lambda]E was 8% higher, owing to larger plant biomass/leaf area and greater soil moisture. Energy balance closure (i.e., [[lambda]E + H] / [R[subscript]n - G]) was 0.87 and 0.90 at the upland and lowland sites, respectively. A nearby large-aperture scintillometer provided good …
-
Investigation of plant water use in the Great Basin, NV
… of shrubs located in these valleys by using a large aperture scintillometer (LAS) to scale up energy balance components (needed to close a water balance) from the canopy level and to determine the potential impacts of altering the water source available to these native vegetation communities. …
-
Impact of time and spatial averages on the energy balance closure
Secondary circulations are large and relatively stationary eddies, which are caused by the surface heterogeneity and normally reside away from the ground. They are believed to be the cause of the energy balance closure problem at the earth's surface, because their contribution to the turbulent …
-
Modeling a variable surface resistance (rs) for alfalfa and assessing the ASCE rs performance in the reference evapotranspiration equation
… and sensible heat flux (H) measured from large aperture scintillometer (LAS). This observed rs showed a very good correlation with leaf area index (LAI) and crop height (hc). The alfalfa rs was then modeled as a function of LAI and hc (which is referred to as rs(LAI) and rs(hc) …
-
Ground and satellite-based assessment of hydrological responses to land cover change in the Kilombero River Basin, Tanzania.
… the measured soil water fluxes which evidenced a large difference in the components of the soil water balance. Less recharge was observed in the Teak forests suggesting significant impacts on the replenishment of groundwater resources in the study area. Assessment of the basin scale impacts of the …
-
An analysis of turbulent sensible heat fluxes within a heterogeneous black spruce boreal forest in Alaska
… locally measured fluxes will likely differ from large-scale area averaged values. The third evaluation compares locally measured sensible heat fluxes from a sonic anemometer atop a 24 m micrometeorological tower to those derived from a large aperture scintillometer (LAS) whose beam is centered …