Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 56 for “"Laser Doppler Anemometer"”.
-
A rapidly scanning three-velocity-component laser Doppler anemometer
… three-velocity - component laser Doppler anemometer has been developed. It permits scans through 3-dimensional flows to obtain space-time velocity information. Since it has lower signal-averaging bias than pointwise measurements, only short record times are required to obtain …
-
Laser doppler anemometer measurements of Reynolds stresses in a fully developed pipe flow
A laser Doppler Anemometer (LDA) is used to make Reynolds stress measurements in a fully developed, turbulent pipe flow. Traverses are made to measure shear stress, normal stresses, and the correlation coefficient. To assess the accuracy of this system, these measurements are compared with results …
-
Index of refraction corrections for laser doppler anemometer measurements in cylindrical and conical geometries
Thesis (M.S.)--Michigan State University. Department of Chemical Engineering, 1985
-
Total velocity vector measurements in an axial-flow compressor using a 3-component Laser Doppler Anemometer
A three-color, three-component Laser Doppler Anemometer (LOA) capable of making simultaneous measurements of three components of velocity is described, and the use of this LOA to measure three non-orthogonal velocity components in the rotor blade passage of a single-stage axial-flow compressor is …
-
Measurements of the length of the zone of flow establishment in a jet using a Laser Doppler Anemometer
… quiescent ambient fluid was investigated using a Laser Doppler Anemometer and microthermocouple probe. Also, velocity and temperature profiles were measured through various cross-sections of the jet; A 3-dimensional traversing mechanism with feedback and interface circuitry was constructed and …
-
Effect of electrically driven particles on air flow in a rectangular duct
… range of 0 to 8.125 kv/cm was determined using a Laser Doppler Anemometer. In the duct, the effect of the electrically driven (actually oscillating) particles on the air flow was investigated;The pressure drop, particle vertical and horizontal velocities were measured along the duct for copper and …
-
Laser-Doppler velocimetry and viscous computation of the flow through a compressor cascade near stall
Laser-Doppler velocimeter measurements were made in the flow field of a stalled cascade of controlled-diffusion stator blades. Tests were conducted at 10 degrees of incidence above the design inlet-flow angle in order to verify previous measurements. A unique method of data presentation was offered …
-
Experimental and numerical investigations of the off-design flow physics in a supersonic through-flow fan cascade
… studied experimentally using a two-component Laser Doppler Anemometer. The cascade was tested in the Virginia Polytechnic Institute and State University intermittent wind tunnel facility, where the experimental Mach and Reynolds numbers were 2.36 and 4.8 x 10⁶, respectively. In addition to …
-
Experimental determination of the flow field velocity and strain rate in a laminar opposed flow H₂/air diffusion flame, via laser doppler anemometry
… two different operating flow rates, via the laser Doppler anemometer. The experimental results are used to assess current counterflow diffusion flame modeling approximations. The data shows that the radial velocity is approximately linear with radial coordinate, as assumed by most modelings. …
-
Experimental determination of strain rates in stretched laminar diffusion flames
A laser Doppler anemometer was used to measure the axial and radial velocity components of hydrogen-air counterflow diffusion flames (CFDF). An axisymmetric opposed jet burner (OJB) used seeded air in one cylindrical tube, and a hydrogen-nitrogen mixture in the opposing cylindrical tube. Velocity …
-
Vergleich der biochemischen Qualität von Erythrozytenkonzentraten, gewonnen durch Multikomponentenspende oder herkömmliche Vollblutspende und Einfluß auf ausgewählte biochemische Laborparameter und in-vivo-Mikrozirkulation des Spenders
… Blutflußrate kapillarmikroskopisch mit dem CAM 1 Laser Doppler Anemometer am Fingermittelglied des dritten Fingers der linken Hand bestimmt. Dabei ließen sich keine signifikanten Steigerungen der kapillären Blutflußrate nachweisen.
-
Experimental and Numerical Investigations of Velocity and Turbulent Quantities of a Jet Diffusion Flame
… and combusting jets were made with a laser Doppler anemometer to validate numerical models. Excellent agreement was found between predicted and measured velocity and turbulent quantities for cold flow cases. However, numerical predictions did not agree quite as well with experiments of …
-
An experimental investigation of the turbulent flow in a closed compound channel
A three-component laser Doppler anemometer was used to measure the fully developed, turbulent flow in a closed, symmetric, smooth-wall compound channel. Measurements were made across one quadrant of the cross-section since the flow was assumed symmetric. Measurements were made for a single channel …
-
Design and experimental study with laser doppler anemometry of a circulating fluidized bed
… De pilootinstallatie werd voorzien van een 3D Laser Doppler Anemometer waarmee de meting van de vaste fase (deeltjes) snelheden mogelijk is. Een volledig 3D stromingsbeeld wordt experimenteel verkregen, niet alleen in de zone met volledig ontwikkelde stroming, maar ook werden inlaat en uitlaat …
-
Turbulent boundary layers over receiver arrays
… 20 element hydrophone array and a two-component Laser Doppler Anemometer, respectively. Estimates of the velocity power spectral density (PSD) revealed two primary trends predicted by turbulence theory, k⁻¹ in the region of (ky) = 10⁰ due to anisotropy of the large scales, and k⁻⁵/³ for larger …
-
An experimental study of electrically induced flow in a dielectric liquid
In this thesis a laser-doppler anemometer is combined with a mobility measurement system and the true mobility of negative charge carriers in hexane is determined. When the measured apparent mobility values are corrected for liquid motion effects, the resulting carrier mobility is found to be 10⁻⁴ …
Page 1 of 3