Showing 1 to 20 of 90 for “"Laser Doppler flowmetry"”.

  1. The assessment of pulpal blood flow using laser Doppler flowmetry

    … overall aim of this work was to study the use of Laser Doppler flowmetry for the assessment of the dental pulp in permanent teeth. The thesis is presented as four distinct studies; 1) A systematic review was carried out to assess the published evidence on the use of laser Doppler flowmetry in the …

    whiterose Download PDF for The assessment of pulpal blood flow using laser Doppler flowmetry (opens in a new tab)

  2. The Vitality Assessment of Traumatised Permanent Anterior Teeth Using Laser Doppler Flowmetry

    … This study investigated the reliability of laser doppler flowmetry as a method of assessing the pulpal status of traumatised permanent anterior teeth. The study found that although laser doppler flowmetry could record pulpal blood flow, non-pulpal signals were an unavoidable component of the …

    glasgow Download PDF for The Vitality Assessment of Traumatised Permanent Anterior Teeth Using Laser Doppler Flowmetry (opens in a new tab)

  3. Intra-operative optical monitoring of bowel tissue viability based on photoplethysmography and laser doppler flowmetry

    … study was to combine the established techniques, laser Doppler flowmetry (LDF) and Photoplethysmography (PPG), into one probe intended for assessment of perfusion in abdominal tissue during bowel resection intraoperatively. In PPG, changes in transmission of light through tissue due to pulsation …

    city-london Download PDF for Intra-operative optical monitoring of bowel tissue viability based on photoplethysmography and laser doppler flowmetry (opens in a new tab)

  4. Evaluation of Laser Doppler Flowmetry and Transillumination Laser Speckle Contrast Imaging to Measure Blood Flow Change in Ischemia Mouse Hindlimb Models

    … with cost or diameter resolution. The use of lasers to measure blood flow helps resolve these issues. Therefore, the studies in this thesis aimed to adapt two methods of measuring blood flow with lasers within the confines of the lab: Laser Doppler Flowmetry (LDF) using probes to measure …

    calpoly Repository record for Evaluation of Laser Doppler Flowmetry and Transillumination Laser Speckle Contrast Imaging to Measure Blood Flow Change in Ischemia Mouse Hindlimb Models (opens in a new tab)

  5. A Multimethod Investigation of Women's Sexual Arousal

    … genital response—the litmus test strip and the laser Doppler imager—were used concurrently to provide the first empirical evidence of the positive relationship between genital lubrication and blood flow during sexual arousal. Both measures detected a genital response and were suitable for …

    queens Repository record for A Multimethod Investigation of Women's Sexual Arousal (opens in a new tab)

  6. The development of biomedical instrumentation using backscattered laser light

    … in the microcirculation using the techniques of laser Doppler flowmetry and pulse oximetry. An investigation of the responses of Doppler flowmeters using different signal processing bandwidths and laser sources revealed two major findings. Firstly, that careful choice of processing bandwidth is …

    oxford-brookes Repository record for The development of biomedical instrumentation using backscattered laser light (opens in a new tab) Download PDF for The development of biomedical instrumentation using backscattered laser light (opens in a new tab)

  7. Echo Planar Functional MR Imaging: To Study the Hemodynamics of Renal Function

    … the results using implanted optical fibers and Laser Doppler Flowmetry. The fibers were implanted in three regions of the kidney for Laser-Doppler flowmetry. Comparison of the laser flowmetry signals obtained with the infusion of diuretic : furosemide indicated a decrease in renal blood flow in …

    marquette Repository record for Echo Planar Functional MR Imaging: To Study the Hemodynamics of Renal Function (opens in a new tab)

  8. Complexity of flow motion

    … derived from skin microvascular networks using Laser Doppler flowmetry (LDF) have been broadly investigated using both linear and nonlinear dynamical methods providing significant information about the microvascular function. This study aims to explore complexity methods that can quantify the …

    soton Download PDF for Complexity of flow motion (opens in a new tab)

  9. A study of the mechanical and microcirculatory properties in skin subject to venous ulceration

    … durometry, uniaxial extensometry and laser Doppler flowmetry were chosen for the measurements. Durometry and extensometiy were found reliable. In controls, measurements demonstrated regional variations in the mechanical properties, and differences with age. In the elderly, …

    soton Download PDF for A study of the mechanical and microcirculatory properties in skin subject to venous ulceration (opens in a new tab)

  10. Dento-alveolar distraction and resulting tooth vitality

    … measurements of the teeth following distraction. Laser Doppler Flowmetry was used pre and post treatment to evaluate vitality. The transport segments were harvested with surrounding bone and analyzed under μCT. Results: There was no loss in vitality in the distracted teeth. No root resorption was …

    tamu Repository record for Dento-alveolar distraction and resulting tooth vitality (opens in a new tab)

  11. Tissue Response of the Lower Extremities During Controlled Loading

    In this study, a rate controlled indentor with Laser Doppler flowmetry (LDF) was used to load tissue, measuring both the reaction force and local tissue perfusion at two sites on the posterior calf. These tests were conducted on eight subjects with varying vascular health to identify potential new …

    marquette Repository record for Tissue Response of the Lower Extremities During Controlled Loading (opens in a new tab)

  12. Microvascular Function in Metabolically Healthy Groups Differing in BMI and Waist Circumference

    … by measuring skin blood flow (SkBF) using laser Doppler flowmetry during postocclusive reactive hyperemia (PORH). The area under the SkBF time curve during the 60-second PORH response was used to quantify the magnitude of the microvascular response. RESULTS: Group I (control) had a …

    byu Repository record for Microvascular Function in Metabolically Healthy Groups Differing in BMI and Waist Circumference (opens in a new tab) Download PDF for Microvascular Function in Metabolically Healthy Groups Differing in BMI and Waist Circumference (opens in a new tab)

  13. Micro- and macro-vascular function in obstructive sleep apnoea

    … controls, using flow mediated dilatation (FMD), laser Doppler flowmetry (LDF), flow cytometry in addition to studying vascular elastic properties. I also performed myocardial contrast echocardiography (MCE) and real time three-dimensional echocardiography (RT3DE). All these tests were repreated …

    birmingham Download PDF for Micro- and macro-vascular function in obstructive sleep apnoea (opens in a new tab)

  14. Age Attenuated Cutaneous Vasoconstrictor Response to Norepinephrine Is Apparent with Bretylium Tosylate

    … pretreated. Skin blood flow was measured by laser-Doppler flowmetry and expressed as cutaneous vascular conductance (laser-Doppler flux/mean arterial blood pressure). The EC₅₀ of the dose response curves were similar between young and old subjects (EC₅₀ = -5.18±0.27 and -5.46±0.23 log M, …

    mo-state Repository record for Age Attenuated Cutaneous Vasoconstrictor Response to Norepinephrine Is Apparent with Bretylium Tosylate (opens in a new tab)

  15. The Effect of Methylphenidate on Cutaneous Blood Flow During Passive Hyperthermia: The Role of Nitric Oxide

    … mg) ingestion in 6 adult males (23 ± 2 y) using laser-Doppler flowmetry and L-NAME to inhibit NOS (Nitric Oxide Synthase). Increasing Tc led to higher forearm cutaneous vascular conductance (CVC) (p < 0.05) and area under the curve of CVC (AUC) (p < 0.001) measures. L-NAME had a significant …

    brock Repository record for The Effect of Methylphenidate on Cutaneous Blood Flow During Passive Hyperthermia: The Role of Nitric Oxide (opens in a new tab)

  16. Test methods for assessing topical formulations

    … during product assessment. The performance of laser Doppler flowmetry for monitoring cutaneous vasodilation has been evaluated using various nicotinic acid esters as model compounds. Results indicate that the time taken for the nicotinates to elicit a response by the flowmeter, is the most …

    aston Download PDF for Test methods for assessing topical formulations (opens in a new tab)

  17. Insulin-induced endothelial cell proliferation and viability in stretched murine skin and cell culture

    … and sternum served as postoperative controls. Laser Doppler flowmetry demonstrated a three-fold increase in flap perfusion at postoperative day 7. A stretch-induced six-fold increase in EC mitogenesis accompanied enhancements in blood flow and extracorporal wound healing over the sternum. …

    wvu Repository record for Insulin-induced endothelial cell proliferation and viability in stretched murine skin and cell culture (opens in a new tab)