Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 7 of 7 for “"Lateral Pile Resistance"”.
-
Lateral Resistance of Pipe Piles Behind a 20-Foot-Tall MSE Wall with Welded-Wire Reinforcements
Pile foundations for bridges must often resist lateral loads produced by earthquakes and thermal expansion and contraction of the superstructure. Right-of-way constraints near bridge abutments are leading to an increased use of mechanically stabilized earth (MSE) walls below the abutment. Previous …
-
Kinematic Demands on Pile-Supported Wharves Due to Liquefaction-Induced Lateral Ground Deformations
Kinematic demands from lateral soil deformations can be a major cause of damage to maritime and highway transportation structures such as wharves, ports, and bridges. Data from five centrifuge tests on pile-supported wharves were used to evaluate the accuracy of Newmark Sliding Block Analysis in …
-
Lateral Resistance of Piles Near Vertical MSE Abutment Walls
A full scale MSE wall was constructed and piles were driven at various distances behind the wall. Lateral load testing was conducted and the performance of the pile, wall, and reinforcement were measured. The piles were 12.75 inch pipe piles, and the wall was reinforced with welded wire grid …
-
Lateral Resistance of Piles at the Crest of Slopes in Sand
Pile foundations near the crest of a slope are often required to resist lateral loads. This is particularly important for piles at the abutments of bridges. However, limited full-scale test data are available to indicate how the lateral resistance of a pile would be affected when it is located near …
-
Lateral Resistance of Pipe Piles Near 20-ft Tall MSE Abutment Wall with Strip Reinforcements
Full scale lateral load testing was performed on four 12.75x0.375 pipe piles spaced at 3.9, 2.9, 2.8, and 1.7 pile diameters behind an MSE wall which was constructed for this research to determine appropriate reduction factors for lateral pile resistance based on pile spacing behind the back face …
-
Lateral Resistance of 24-inch Statically Loaded and 12.75-Inch Cyclically Loaded Pipe Piles Near a 20-ft Mechanically Stabilized Earth (MSE) Wall
Installing load bearing piles within the reinforcement zone of mechanically stabilized earth (MSE) retaining walls is common practice in the construction industry. Bridge abutments are often constructed in this manner to adapt to increasing right-of-way constraints, and must be capable of …
-
Lateral Resistance of Grouped Piles Near 20-ft Tall MSE Abutment Wall with Strip Reinforcements
… Young University and I performed full-scale lateral load tests on individual and grouped 12.75x0.375 inch pipe piles spaced at varying distances behind an MSE wall. The individually loaded pile which acted as a control was spaced at 4.0 pile diameters from the wall face, and the three grouped …