Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 103 for “"Lateral Resistance"”.
-
Axial and Lateral Resistance of Non-Displacement Piles
… or horizontal loads, the mechanisms of the resistance mobilization and the implementation of the research findings in pile design practice. A series of three-dimesional finite element analyses were performed with an advanced, two-surface constitutive sand model to investigate the response of …
-
Lateral Resistance of Piles Near Vertical MSE Abutment Walls
… driven at various distances behind the wall. Lateral load testing was conducted and the performance of the pile, wall, and reinforcement were measured. The piles were 12.75 inch pipe piles, and the wall was reinforced with welded wire grid reinforcement. The objective of the testing was to …
-
Lateral Resistance of Piles Near Vertical MSE Abutment Walls
Full scale lateral load tests were performed on five piles located at various distances behind MSE walls. Three of the five test piles were production piles used to support bridges, and the other two piles were located behind a MSE wing walls adjacent to the bridge abutment. The objective of the …
-
Railroad Tie Lateral Resistance on Open Deck Plate Girder Bridges
… such as hook bolts. These fasteners provide lateral resistance for the bridge ties. Currently there are no provisions to assist in the calculation of lateral resistance provided by railroad ties on open-deck bridges, and as a result there are no specific requirements for the spacing of deck …
-
Lateral Resistance of Piles at the Crest of Slopes in Sand
… crest of a slope are often required to resist lateral loads. This is particularly important for piles at the abutments of bridges. However, limited full-scale test data are available to indicate how the lateral resistance of a pile would be affected when it is located near the crest of a slope. …
-
Impact of Mass Mixing on the Lateral Resistance of Driven-Pile Foundations
… better understand the effect of soil mixing on lateral resistance of pile caps. To do this, in-situ soil mixing was used to strengthen weak clay adjacent to a pile cap of a driven pile foundation. The mass stabilization method or mass mixing was used to treat an 11 ft wide, 4 ft thick, and 10 ft …
-
Lateral Resistance of Piles Near Vertical MSE Abutment Walls at Provo Center Street
Full scale lateral load tests were performed on four piles located at various distances behind MSE walls. Three of the four test piles were production piles used to support bridges, and the other pile a production pile used as part of the bridge abutment. The objective of the testing was to …
-
The Effect of Flowable Fill on the Lateral Resistance of Driven-Pile Foundations
… the piles showed no appreciable increase in lateral resistance, this was partially due to the fact that the flowable fill placed had an unconfined compressive strength of 30 psi. Flowable fill was also used to replace a 12 ft wide, 6 ft thick, and 6 ft deep zone consisting of an average 475 …
-
Determination of Lateral Resistance of Deck Tie Fasteners in Smooth Top Bridge Girders
… preliminary design aids for the determination of lateral resistance capacity and spacing requirements of deck tie fasteners in curved railroad bridges with smooth top girders. In railroad bridge design, required lateral resistance dictates the spacing of deck tie fasteners. Currently, no …
-
Examination of the Lateral Resistance of Cross-Laminated Timber in Panel-Panel Connections
… The viability of CLT as an element to resist lateral forces from racking has been of great interest (Dujic et al. 2004, Blass and Fellmoser 2004, and Moosbrugger et al. 2006). However, most research to date has been conducted on full-scale wall panels connected with proprietary fasteners …
-
Lateral resistance of new mid-ply shear wall (MPSW2) connections – performance of different materials
… systems with the objective to understand the lateral resistance of these connections and develop reliable models for further analysis. The research includes monotonic and reversed cyclic loading tests with loading directions parallel to the grain, specific gravity, and moisture content tests, …
-
Lateral resistance of traditional Japanese post-and-beam frames under monotonic and cyclic loading conditions
… and OSB sheathed frames) to determine the lateral loading resistance under monotonic and cyclic loading procedures. Twelve tests were conducted on 2.62 x 2.70 m frames, constructed with British Columbia Hem-fir timber and oriented strand board panels as sheathing (JIS - Japanese grade) …
-
Lateral Resistance of Grouped Piles Near 20-ft Tall MSE Abutment Wall with Strip Reinforcements
… Young University and I performed full-scale lateral load tests on individual and grouped 12.75x0.375 inch pipe piles spaced at varying distances behind an MSE wall. The individually loaded pile which acted as a control was spaced at 4.0 pile diameters from the wall face, and the three grouped …
-
Lateral Resistance of Pipe Piles Near 20-ft Tall MSE Abutment Wall with Strip Reinforcements
Full scale lateral load testing was performed on four 12.75x0.375 pipe piles spaced at 3.9, 2.9, 2.8, and 1.7 pile diameters behind an MSE wall which was constructed for this research to determine appropriate reduction factors for lateral pile resistance based on pile spacing behind the back face …
-
Effectiveness of Compacted Fill and Rammed Aggregate Piers for Increasing Lateral Resistance of Pile Foundations
… founded in soft clay. The compacted fill used to laterally reinforce an area of 11 ft by 5 ft by 6 ft deep adjacent to the pile cap was clean concrete sand. The thirty-inch diameter RAPs were installed in three staggered rows to a depth of 12.5 ft below the ground surface adjacent to the pile cap …
-
Lateral Resistance of Pipe Piles Behind a 20-Foot-Tall MSE Wall with Welded-Wire Reinforcements
Pile foundations for bridges must often resist lateral loads produced by earthquakes and thermal expansion and contraction of the superstructure. Right-of-way constraints near bridge abutments are leading to an increased use of mechanically stabilized earth (MSE) walls below the abutment. Previous …
-
Lateral Resistance of Piles near 15 Foot Vertical MSE Abutment Walls Reinforced with Ribbed Steel Strips
ABSTRACTLateral Resistance of Piles near 15 Foot Vertical MSE AbutmentWalls Reinforced with Ribbed Steel StripsJarell Jen Chou HanDepartment of Civil and Environmental Engineering, BYUMaster of ScienceA full scale MSE wall was constructed and piles were driven at various distances behind the wall. …
-
Preliminary analysis and design of a test setup for evaluating lateral resistance of steel gravity framing systems
… few frames of the building that resists lateral loads, and the remainder of the structure is designed to resist only gravity loads. The elements of this gravity system are connected using “simple shear” connections that are designed and assumed to behave as “perfect pins” that have no …
-
Lateral Resistance of H-Piles and Square Piles Behind an MSE Wall with Ribbed Strip and Welded Wire Reinforcements
… pile foundations behind MSE walls to help resist lateral loading from seismic and thermal expansion and contraction loads. Overdesign of pile spacing and sizes occur owing to a lack of design code guidance for piles behind an MSE wall. However, space constraints necessitate the installation of …
-
Lateral Resistance of 24-inch Statically Loaded and 12.75-Inch Cyclically Loaded Pipe Piles Near a 20-ft Mechanically Stabilized Earth (MSE) Wall
… Previous researchers have concluded that lateral pile resistance is reduced when pile are placed next to MSE walls but no design codes have been established to address this issue. Full –scale testing of statically applied lateral loads to four 24”x0.5” pipe piles, and cyclically applied …
Page 1 of 6