Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 89 for “"Lateral force resisting system"”

  1. Bio-Inspired Segmented Self-Centering Rocking Frame

    … and modeling of a human spine-inspired seismic lateral force resisting system. The overall goal is to create a design for a lateral force resisting system that reflects human spine behavior that is both practical and effective. The first phase of this project involved a literature review of the …

    vt Repository record for Bio-Inspired Segmented Self-Centering Rocking Frame (opens in a new tab)

  2. Eccentrically braced steel frames as a seismic force resisting system

    Braced frames are a common seismic lateral force resisting system used in steel structure. Eccentrically braced frames (EBFs) are a relatively new lateral force resisting system developed to resist seismic events in a predictable manner. Properly designed and detailed EBFs behave in a ductile …

    ksu Repository record for Eccentrically braced steel frames as a seismic force resisting system (opens in a new tab)

  3. Inelastic Analysis of Steel Moment Resisting Frames in Light-Framed Wood Buildings

    … quantitative analysis of steel moment resisting frames as the lateral force-resisting system for light-framed wood buildings was completed to identify issues requiring more advanced study. A two-story prototype building was evaluated. The lateral force-resisting system of the building …

    sjsu Repository record for Inelastic Analysis of Steel Moment Resisting Frames in Light-Framed Wood Buildings (opens in a new tab)

  4. Enhancing Seismic Resiliency of Steel Buildings through Three-Dimensional Modeling of Diaphragm System Interaction with Braced Frame

    … designed to meet the component deformation and force capacities. The lateral-force resisting system, key for developing successful seismic performance, has two main parts: 1) the Vertical Lateral-force resisting system (VLFRS) of which a common example in steel buildings is the braced frame, and …

    jhu Repository record for Enhancing Seismic Resiliency of Steel Buildings through Three-Dimensional Modeling of Diaphragm System Interaction with Braced Frame (opens in a new tab)

  5. Buckling restrained braced frames as a seismic force resisting system

    … continually look for new and better methods of resisting seismic forces. Buckling restrained braced frames (BRBF) are a relatively new lateral force resisting system developed to resist highly unpredictable seismic forces in a very predictable way. Generally, structures with a more ductile …

    ksu Repository record for Buckling restrained braced frames as a seismic force resisting system (opens in a new tab)

  6. Design and construction of tall mass timber buildings with resilient post-tensioned mass timber rocking walls

    … Mass timber, especially in the form of gravity systems, has been an appealing alternative to building with other nonrenewable materials for the past couple of decades. Mass timber lateral systems, particularly in the form of post-tensioned mass timber rocking walls, have been proven to be a …

    colo-mines Repository record for Design and construction of tall mass timber buildings with resilient post-tensioned mass timber rocking walls (opens in a new tab)

  7. Experimental and Analytical Inelastic Behavior of C- and T- Shaped Composite Plate Shear Walls/Concrete-Filled (C-PSW/CF)

    … Wall/Concrete Filled (C-PSW/CF) is a special lateral-force resisting system consisting a sandwiched panel of two steel plates with concrete infill in between them, ideally suited for core-wall structures in high-rise construction. The steel plates are connected to each other using tie bars …

    buffalo Repository record for Experimental and Analytical Inelastic Behavior of C- and T- Shaped Composite Plate Shear Walls/Concrete-Filled (C-PSW/CF) (opens in a new tab)

  8. Beam-column connection flexural behavior and seismic collapse performance of concentrically braced frames

    … and field observations demonstrated that reserve lateral force-resisting capacity due to the flexural strength of connections outside the primary lateral force-resisting system of steel frames can maintain structural stability if the primary system is damaged. Several experimental studies were …

    uiuc Repository record for Beam-column connection flexural behavior and seismic collapse performance of concentrically braced frames (opens in a new tab)

  9. Multi-hazard performance of steel moment frame buildings with collapse prevention systems in the central and eastern United States

    … the potential for using a conventional main lateral-force resisting system, combined with the reserve strength in the gravity framing, and or auxiliary collapse-inhibiting mechanisms deployed throughout the building, or enhanced shear tab connections, to provide adequate serviceability …

    vt Repository record for Multi-hazard performance of steel moment frame buildings with collapse prevention systems in the central and eastern United States (opens in a new tab)

  10. Behavior and large-scale experimental testing of Steel Plate Shear Walls with Coupling

    … Steel Plate Shear Wall (SPSW) seismic lateral force resisting system. The SPSW system is composed of a steel frame with web plates between the beams and columns. In North America, the web plates of the SPSW are typically slender and unstiffened and dissipate energy through yielding of a …

    uiuc Repository record for Behavior and large-scale experimental testing of Steel Plate Shear Walls with Coupling (opens in a new tab)

  11. An approach to light-frame disaster relief housing

    … loads determined for the region. The structural system is designed using bamboo and includes a lateral force resisting system, and gravity force resisting system, and roof and floor diaphragms. The structural system ties into the foundation, which was designed to withstand flood loads and provide …

    santa-clara Repository record for An approach to light-frame disaster relief housing (opens in a new tab)

  12. Ductile Design and Predicted Inelastic Response of Steel Moment Frame Buildings for Extreme Wind Loads

    … due to the inherent differences between seismic forces and wind forces. Current wind design practice follows a linear method to find a design windspeed for the location where the structure will be built. Once the design windspeed has been determined, the lateral force resisting system is designed …

    byu Repository record for Ductile Design and Predicted Inelastic Response of Steel Moment Frame Buildings for Extreme Wind Loads (opens in a new tab)

  13. Seismic behavior and design of steel plate shear walls with beam-connected plates

    Steel plate shear walls (SPSW) are a reliable lateral force-resisting system with high ductility, stable hysteretic response, and high lateral stiffness. The main lateral force-resisting elements of a SPSW are thin steel infill plates (web plates) that are connected to columns and beams on four …

    texas Repository record for Seismic behavior and design of steel plate shear walls with beam-connected plates (opens in a new tab)

  14. Analytical Investigation into the Effect of Axial Restraint on the Stiffness and Ductility of Diagonally Reinforced Concrete Coupling Beams

    … on the stiffness and ductility of diagonally reinforced concrete coupling beams are investigated analytically through the use of finite element analysis. To provide accurate result without undue computational expense, a mesh sensitivity study is performed to determine the optimal mesh of the …

    ohiolink Repository record for Analytical Investigation into the Effect of Axial Restraint on the Stiffness and Ductility of Diagonally Reinforced Concrete Coupling Beams (opens in a new tab)

  15. STRUCTURAL ASSESSMENT OF MULTIPLE STORY STEEL BUILDINGS SUBJECTED TO BLAST LOADS

    … order to analyze the effects of blast loads on lateral force resisting systems in hardened multistory steel buildings. The results obtained are targeted towards improving the design of buildings such as hospitals and defense offices which must maintain some level of serviceable operations in the …

    ohiolink Repository record for STRUCTURAL ASSESSMENT OF MULTIPLE STORY STEEL BUILDINGS SUBJECTED TO BLAST LOADS (opens in a new tab)

  16. Evaluating the Use of Ductile Envelope Connectors for Improved Blast Protection of Buildings

    … the energy from a blast event, leaving the lateral force resisting system (LFRS) and envelope panel undamaged.

    ohiolink Repository record for Evaluating the Use of Ductile Envelope Connectors for Improved Blast Protection of Buildings (opens in a new tab)

  17. Performance of concrete Special Moment Frames during Mainshock-Aftershock sequences with varying dominant frequency ranges of ground motions

    … looks at concrete Special Moment Frames as the lateral force-resisting system. Five sequences were included in the study varying either the stiffness of the structure or the frequencies of the earthquakes. The structural damage was quantified by plastic hinge formation and story displacement …

    texas Repository record for Performance of concrete Special Moment Frames during Mainshock-Aftershock sequences with varying dominant frequency ranges of ground motions (opens in a new tab)

  18. Comparison of structural steel lateral force resisting systems for a theoretical hospital grid system

    … computer modeling was used to explore a set of lateral force resisting system (LFRS) options for a building based on this optimum bay size and importance category. The structural material was first narrowed down to steel, and then moment frames and braced frames are examined. The LFRS was …

    ksu Repository record for Comparison of structural steel lateral force resisting systems for a theoretical hospital grid system (opens in a new tab)

  19. Modal investigation of the Usibelli Building using spectral and dynamic analysis

    … a computer model of the building’s structural Lateral Force Resisting System. Power spectrum density plots were generated using a Fast Fourier transform routine within MATLAB to identify the natural periods of the building. A building model was created in RISA-3D using construction plan sets to …

    alaska Repository record for Modal investigation of the Usibelli Building using spectral and dynamic analysis (opens in a new tab)

Page 1 of 5