Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 19 of 19 for “"Lead Screw"”.
-
Friction-induced Vibration in Lead Screw Systems
Lead screw drives are used in various motion delivery systems ranging from manufacturing to high precision medical devices. Lead screws come in many different shapes and sizes; they may be big enough to move a 140 tons theatre stage or small enough to be used in a 10ml liquid dispensing micro-pump. …
-
Design and Performance Evaluation of Linear and Axial-Flux Magnetic Gears
… of magnetic gears; first a magnetically-geared lead screw is proposed, which converts a low speed linear motion to a high speed rotary motion. The proposed actuator is a combination of two previously proposed actuators, the linear magnetic gear and the magnetic lead screw. Unlike these two …
-
Modeling, Simulation and Optimization of Electromagnetic Systems
… is proposed in double-sided magnetic lead screw (MLS). An analytical model is developed based on the subdomain method to calculate the magnetic field distribution. This allows calculating the electromagnetic performances such as the generated thrust force. The analytical model is …
-
High-Speed Applications for Electromagnetic Propulsion Technology
In this thesis, different types of the magnetic lead screw systems are considered, and the effects of the key design parameters, such as magnet thickness, air-gap length, pole-pitch, number of pole-pairs, dimension etc. on the force/torque transmission are investigated. Moreover, research into the …
-
Construction and preliminary test of a traversing stagnation pressure probe for a labor scale aerothermopressor
… were constructed for these probes. One employs a lead screw and universal joint, geared drive with a counter to determine the position of the probe within the duct. The other arrangement merely provides support for the probe and traversing is done by hand with the probe position determined by a …
-
DESIGN OF A NOVEL ROBOTIC SURGICAL INSTRUMENT
… The design of the transmission mechanism (lead screw plus slider-crank) has been analysed and an optimization algorithm for the slider-crank parameters has been developed. Design calculations have been conducted to analyse the kinematics and static loading of the device and finite element …
-
Optimal trajectory generation and precision tracking control for multi-axis machines
… filter. The structural dynamics of the ball screw mechanism are identified by conducting frequency response tests, while the axis is already in motion, in order to decouple the interfering effect of stick-slip friction. The torsional vibrations of the lead screw, as well as translational …
-
Synthesis and Design of a Bimodal Rotary Series Elastic Actuator
… actuated with a pantograph linkage and ACME lead screw. This configuration produced 11 Nm of holding torque experimentally but was theoretically shown to produce up to 51.4 Nm with larger motors. The elastic element was designed using finite element analysis (FEA) and tested experimentally to …
-
Development and evaluation of an improved positioning scheme for a cyclotron ion source
… design uses stepper motors and a differential lead- screw drive system controlled by a personal computer.</p> <p>A mathematical model describing the three degree-of-freedom system is developed and evaluated. The resultant closed-form solution is incorporated into a C program which operates on …
-
A Study Exploring the Use of Artificial Ligaments to Enhance the Human-Robot Interface Via Force Distribution Manipulation in Biomimetic Cuff Systems
… Powered by a step motor, the rig makes use of a lead screw to translate rotational motion into linear translation. Overall, a cuff system and testing rig have been designed and fabricated. Some future work to consider includes evaluating wearable ankle robots at the human-robot interface level …
-
Electromagnetic design, analysis, and optimization of an interior permanent magnet motor for robotic application
… fixed transmission (e.g., a gear stage driving a lead screw or linkage), actuator selection should be based on torque-speed capability under electrical limits rather than torque at a single low-speed point. This thesis evaluates the potential of an interior permanent-magnet synchronous motor (IPM) …
-
Trans-Rotary Magnetic Gear for Wave Energy Application
This dissertation looks into a type of magnetic gear, referred to as the Trans-Rotary Magnetic Gear (TROMAG), for reciprocating Wave Energy Converters (WECs). A TROMAG consists of two main parts: a translator that is coupled, mechanically or magnetically, to a buoy and a rotor that is coupled to a …
-
Projeto e desenvolvimento de um fuso magnético de relutância variável
Esta dissertação aborda o desenvolvimento de um fuso magnético de relutância variável com topologia de caráter inovador. Este dispositivo magnético é composto de um translator, que se desloca linearmente ao longo de um eixo, e um rotor que gira em torno do mesmo eixo. Ele é capaz de converter, sem …
-
Návrh lisu na ovoce
Domácí výroba ovocných šťáv a moštů zažívá v posledních letech rostoucí popularitu. Tato bakalářská práce se zaměřuje na návrh lisu na ovoce, schopného vyvinout přítlačnou sílu až 3 tuny s možností jak automatického, tak ručního pohonu. Rešeršní část práce odhaluje mezeru na trhu, kde dostupné …
-
Testování dlouhodobé přesnosti a opakovatelnosti lineárních polohovacích zařízení
Měření skutečných vlastností lineárních polohovacích mechanismů je důležitou součástí jejich návrhu. Umožňuje důkladně porozumět klíčovým prvkům, které mohou být zdrojem nepřesného polohování. Tato práce má za úkol ve spolupráci s firmou Thermo Fisher Scientific Brno s.r.o. připravit a otestovat …
-
Komplexní model elektro-mechanické soustavy
Tato bakalářská práce se zabývá komplexními modely elektro-mechanických soustav. Tvoří ji literární rešerše na téma diagnostika založená na modelech a praktická část, zabývající se tvorbou daného modelu DC motoru s elektrickou, mechanickou a teplotní částí pomocí knihovny Simscape v programu …
-
Návrh přenosného dílenského zvedacího zařízení pro motorové vozidlo
Táto bakalárska práca sa venuje problematike mobilných zdvíhacích zariadení pre osobné automobily. Obsahuje kritickú rešerš, v ktorej sú porovnané existujúce mobilné zdviháky, vlastný návrh mobilného zdvíhacieho zariadenia, jeho rozmerové a pevnostné výpočty, voľbu materiálu a komponentov a …
-
Planetové, cykloidní, šnekové, šroubové, harmonické převodovky
Tato bakalářská práce se zaměřuje na planetové, cykloidní, harmonické, šroubové a šnekové převodovky, poskytuje pohled na konstrukci, výpočty a aplikace těchto mechanismů v přenosu mechanické energie. Obsahuje přehledné schematické nákresy, konstrukční podklady a výpočty převodových poměrů, s …
-
Testing and Advancement of a Variable Stiffness Transverse Plane Adapter for Use in a Lower Limb Prosthesis
… the position of a lever arm via an ACME lead screw. The change in position of the lever arm in relation to a central torsion spring effectively varies the mechanical advantage by modifying the lever arm length. This allows for infinitely variable stiffness between 0.10 Nm/° and fully …