Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 27 for “"Lead and Copper Rule"”.

  1. Addressing gaps in the US EPA Lead and Copper Rule: Developing guidance and improving citizen science tools to mitigate corrosion in public water systems and premise plumbing

    Lead and copper in drinking water are known to pose aesthetic and health concerns for humans and pets. The United States Environmental Protection Agency (US EPA) Lead and Copper Rule (LCR) set 90th percentile action levels for lead (15 ppb) and copper (1.3 mg/L), above which utilities must …

    vt Repository record for Addressing gaps in the US EPA Lead and Copper Rule: Developing guidance and improving citizen science tools to mitigate corrosion in public water systems and premise plumbing (opens in a new tab)

  2. Drinking Water Quality of Seattle Public Schools: A Case of Environmental Equity

    … widespread public outcry over the discovery of lead contamination in water, a significant amount of uncertainty remains around the quality and safety of publicly sourced drinking water throughout the United States. This research investigates the water-quality testing reports of the Seattle …

    washington Repository record for Drinking Water Quality of Seattle Public Schools: A Case of Environmental Equity (opens in a new tab)

  3. Copper Corrosion Demonstration Testing Using Electrochemical Techniques

    The Lead and Copper Rule (LCR), promulgated in 1991, required public water systems to minimize lead and copper corrosion within distribution systems and household plumbing systems. Using treatment chemicals, water quality can be adjusted to produce corrosion resistant deposits on metal surfaces. …

    sdstate Repository record for Copper Corrosion Demonstration Testing Using Electrochemical Techniques (opens in a new tab)

  4. LIMESTONE CONTACTORS AS A CORROSION CONTROL TECHNOLOGY FOR SMALL PUBLIC WATER SYSTEMS: An Educational Module for Drinking Water Professionals

    … contactors technology for small water systems and discusses the process and methodology involved in developing the educational module on limestone contactors. It includes most of the narrative texts presented in the module. Both this thesis and the module are intended to be used as an …

    ut-knoxville Repository record for LIMESTONE CONTACTORS AS A CORROSION CONTROL TECHNOLOGY FOR SMALL PUBLIC WATER SYSTEMS: An Educational Module for Drinking Water Professionals (opens in a new tab)

  5. Sensing harmful ions in water by using water-gated thin-film transistor sensors

    … to detect waterborne analytes (e.g. K+, Na+ and Ca2+) with the help of organic macrocyclic ionophores (sensitisers) incorporated within the membrane in WGTFT’s architecture. The response characteristics of such WGTFT sensors underwent the Nikolsky-Eisenman (modified Nernstian) law, with a …

    whiterose Download PDF for Sensing harmful ions in water by using water-gated thin-film transistor sensors (opens in a new tab)

  6. Bench- and Pilot-Scale Corrosion Control Inhibitor Effectiveness Studies for a Community's Blended Surficial and Brackish Groundwater Supply

    … Environmental Protection Agency regulates the lead and copper content of a public water system's finished water at the consumer's tap, through the Safe Drinking Water Act's Lead and Copper Rule (LCR), promulgated in 1991. This rule was recently changed through the LCR Revisions (LCRR), that …

    ucf Repository record for Bench- and Pilot-Scale Corrosion Control Inhibitor Effectiveness Studies for a Community's Blended Surficial and Brackish Groundwater Supply (opens in a new tab)

  7. Characterizing Waterborne Lead in Private Water Systems

    Lead is a common additive in plumbing components despite its known adverse health effects. Recent research has attributed cases of elevated blood lead levels in children and even fetal death with the consumption of drinking water containing high levels of lead. Although the federal Environmental …

    vt Repository record for Characterizing Waterborne Lead in Private Water Systems (opens in a new tab)

  8. Reconsidering Lead Corrosion in Drinking Water: Product Testing, Direct Chloramine Attack and Galvanic Corrosion

    The ban on lead plumbing materials in the Safe Drinking Water Act (1986) and the EPA Lead and Copper Rule (1991) have successfully reduced lead contamination of potable water supplies. The success of these regulations gave rise to a belief that serious lead contamination was an important past …

    vt Repository record for Reconsidering Lead Corrosion in Drinking Water: Product Testing, Direct Chloramine Attack and Galvanic Corrosion (opens in a new tab)

  9. Examining Aspects of Copper and Brass Corrosion in Drinking Water

    … water industry complies with the new arsenic standard and new treatments are installed, unintended consequences might be expected in relation to corrosion control when sulfate/chloride ratio, pH, phosphate, iron, aluminum, bicarbonate and organic matter levels are altered. In some cases, these …

    vt Repository record for Examining Aspects of Copper and Brass Corrosion in Drinking Water (opens in a new tab)

  10. New Insights into Lead and Copper Corrosion: Impacts of Galvanic Corrosion, Flow Pattern, Potential Reversal, and Natural Organic Matter

    The EPA Lead and Copper Rule set Action Limits for lead and copper concentrations in potable water, but accelerated corrosion of lead in potable water systems due to a galvanic connection to copper remains a significant health risk to consumers. In addition to elevated lead release due to galvanic …

    vt Repository record for New Insights into Lead and Copper Corrosion: Impacts of Galvanic Corrosion, Flow Pattern, Potential Reversal, and Natural Organic Matter (opens in a new tab)

  11. The Impacts of Water Supply Processes on Macronutrient Cycling Across the United States

    … of the macronutrients carbon (C), nitrogen (N) and phosphorus (P) worldwide. This has resulted in a need for more effective nutrient management practices that are informed by accurate nutrient budgets. This thesis uses publicly available data to assess the impacts that human uses of fresh water …

    lancaster Download PDF for The Impacts of Water Supply Processes on Macronutrient Cycling Across the United States (opens in a new tab)

  12. Effects Of Orthophosphate Corrosion Inhibitor In Blended Water Quality Environments

    … orthophosphate (OP) inhibitor addition on iron, copper, and lead corrosion on coupons exposed to different blends of groundwater, surface water, and desalinated seawater. The effectiveness of OP inhibitor addition on iron, copper, and lead release was analyzed by statistical comparison between OP …

    ucf Repository record for Effects Of Orthophosphate Corrosion Inhibitor In Blended Water Quality Environments (opens in a new tab)

  13. Lead(IV) Oxide in Drinking Water Systems: Formation, Dissolution, Redox-driven Recrystallization, and Implications for Lead Control

    Lead (Pb) in tap water is mainly contributed by lead service lines (LSLs). The dissolved lead concentration is controlled by the solubilities of lead corrosion products that form on the inner surface of LSLs. Among these lead corrosion products, lead(IV) oxide (PbO2) has the lowest solubility and …

    wustl Repository record for Lead(IV) Oxide in Drinking Water Systems: Formation, Dissolution, Redox-driven Recrystallization, and Implications for Lead Control (opens in a new tab)

  14. Effects Of Source Water Blending Following Treatment With Sodium Silicate As A Corrosion Inhibitor On Metal Release Within A Wat

    A study was conducted to investigate and quantify the effects of corrosion inhibitors on metal release within a pilot distribution system while varying the source water. The pilot distribution system consisted of pre-existing facilities from Taylor et al (2005). Iron, copper, and lead release data …

    ucf Repository record for Effects Of Source Water Blending Following Treatment With Sodium Silicate As A Corrosion Inhibitor On Metal Release Within A Wat (opens in a new tab)

  15. Lead and Copper Contamination in Potable Water: Impacts of Redox Gradients, Water Age, Water Main Pipe Materials and Temperature

    Potable water can become contaminated with lead and copper due to the corrosion of pipes, faucets, and fixtures. The US Environmental Protection Agency Lead and Copper Rule (LCR) is intended to target sampling at high-risk sites to help protect public health by minimizing lead and copper levels in …

    vt Repository record for Lead and Copper Contamination in Potable Water: Impacts of Redox Gradients, Water Age, Water Main Pipe Materials and Temperature (opens in a new tab)

  16. Biostability In Drinking Water Distribution Systems In A Changing Water Quality Environment Using Corrosion Inhibitors

    … to quantity the effect of inhibitor type and dose on bacterial growth (biofilm and bulk water). Water and pipe coupon samples were taken and examined during the experiments. The coupons were exposed to drinking water at approximately 20°C for at least 5 weeks to allow the formation of a …

    ucf Repository record for Biostability In Drinking Water Distribution Systems In A Changing Water Quality Environment Using Corrosion Inhibitors (opens in a new tab)

  17. Using Electrochemical Monitoring To Predict Metal Release In Drinking Water Distribution Systems

    Corrosion of distribution system piping and home plumbing materials is a major concern in the water community. Iron release adverse affects aesthetic water quality and the release of copper and lead is regulated by the Lead and Copper rule (LCR) and can adversely affect consumer health. Corrosion …

    ucf Repository record for Using Electrochemical Monitoring To Predict Metal Release In Drinking Water Distribution Systems (opens in a new tab)

  18. In-plant And Distribution System Corrosion Control For Reverse Osmosis, Nanofiltration, And Anion Exchange Process Blends

    … water treatment facilities (WTFs) can improve and enhance water quality; however, these same modifications or improvements may adversely affect finished water provided to the consumer by public water systems (PWSs) that embrace these advanced technologies. Process modification or improvements …

    ucf Repository record for In-plant And Distribution System Corrosion Control For Reverse Osmosis, Nanofiltration, And Anion Exchange Process Blends (opens in a new tab)

  19. Understanding Mechanisms of Water Lead Contamination by Nitrate Spallation Corrosion and Lead Removal by Point-of-Use (POU) Filters

    Lead enters drinking water by a process of corrosion, dissolution or particle detachment from lead bearing plumbing materials. Preventing contamination of water from lead-tin solder corrosion and achieving effective removal of particulate lead by point-of-use (POU) filters are important public …

    vt Repository record for Understanding Mechanisms of Water Lead Contamination by Nitrate Spallation Corrosion and Lead Removal by Point-of-Use (POU) Filters (opens in a new tab)

  20. Lead (Pb) Contamination of Potable Water: Public Health Impacts, Galvanic Corrosion and Quantification Considerations

    The issue of lead exposure through drinking water was re-examined in light of modern public health goals, recent high-profile cases of elevated lead in water, and emerging concerns regarding the efficacy of legally mandated remedial strategies. A critical literature review revealed that serious …

    vt Repository record for Lead (Pb) Contamination of Potable Water: Public Health Impacts, Galvanic Corrosion and Quantification Considerations (opens in a new tab)

Page 1 of 2