Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 5 of 5 for “"Leakage jets"”.

  1. The application of passive flow control to bileaflet mechanical heart valve leakage jets

    … and exposure time found in the highly transient leakage jet emanating from the b-datum gap during valve closure is sufficient to cause hemolysis and platelet activation. Regions of flow stasis in the valve vicinity may also allow activated platelets to aggregate and form thrombus. This thesis …

    gatech Repository record for The application of passive flow control to bileaflet mechanical heart valve leakage jets (opens in a new tab)

  2. The Development of a Novel in vitro Flow System to Evaluate Platelet Activation and Procoagulant Potential Induced by Bileaflet Mechanical Heart Valve Leakage Jets

    … higher levels of TAT and also formed jets that were subject to increased entrainment of the stagnant fluid in the chamber. This entrainment enables more mixing of the shear-activated platelets with the surrounding flow, which can propagate the coagulation cascade, thus increasing the …

    gatech Repository record for The Development of a Novel in vitro Flow System to Evaluate Platelet Activation and Procoagulant Potential Induced by Bileaflet Mechanical Heart Valve Leakage Jets (opens in a new tab)

  3. An In Vitro Investigation of the Flow Fields Through Bileaflet and Polymeric Prosthetic Heart Valves

    … recirculation during ventricular diastole while leakage jets over and adjacent to leaflets were prominent during ventricular systole. CM hinge flow had higher RSS than in the SJM hinge. The large gap width hinge had the largest leakage jet size and highest RSS (>400 Pa) during ventricular …

    gatech Repository record for An In Vitro Investigation of the Flow Fields Through Bileaflet and Polymeric Prosthetic Heart Valves (opens in a new tab)

  4. Influence of the Implant Location on the Hinge and Leakage Flow Fields Through Bileaflet Mechanical Heart Valves

    … The present study aimed to investigate the leakage, hinge, and near hinge flow fields of two BMHV under simulated physiologic aortic flow conditions and to compare these results with previous findings in the mitral position to better understand how the implant location influences the valve …

    gatech Repository record for Influence of the Implant Location on the Hinge and Leakage Flow Fields Through Bileaflet Mechanical Heart Valves (opens in a new tab)

  5. Simulation of 3-D viscous compressible flow in multistage turbomachinery by finite element methods

    … migration from upstream blade rows, shocks, tip leakage jets, and vortices interact together as the flow convects through the stages. These interactions contribute significantly to the aerodynamic losses of the system and degrade the performance of the machine. The unsteadiness also leads to …

    concordia Download PDF for Simulation of 3-D viscous compressible flow in multistage turbomachinery by finite element methods (opens in a new tab)