Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 32 for “"Least squares curve fitting"”
-
Phase Shift Determination for Elastic Potential Scattering, Using the IBM 360-50 Computer
… distribution. This was accomplished using a least squares curve fitting routine.
-
An automated least-squares parameter identification technique and optimal PID control
… theory and application. A so-called automated least squares parameter identification algorithm is developed and implemented with a HP desktop computer. This technique can automatically model most stable SISO processes in the first-order-lag-plus-delay (FOLPD) or first-order-lag (POL) form based …
-
Real-time computer optimized scanning potential coulometry for multi-component trace analysis
… found on the electrolysis current. Non-linear least squares curve fitting methods accurately resolved iron-platinum and silver-iron interferences to give accurate determinations for iron and silver. The resolving capability of this method was tested using theoretically generated scanning …
-
FLUORESCENCE SPECTROSCOPY ANALYSIS THROUGH CONVOLUTIONAL NEURAL NETWORKS
… 2,500 frames against the conventional non-linear least squares curve fitting approach in Imaging FCS method, in terms of mean squared error. We demonstrate using scatter plots that our network predictions for lipid bilayer data are comparable to Imaging FCS.
-
Hefner model parameters for power IGBTS under pulsed power conditions
… both experimental and simulated data with a least squares curve fitting technique, the parameters necessary to model a given IGBT can be determined. This thesis presents two sets of these seventeen parameters that correspond to two different models of power IGBTs. Specifically, these …
-
Dispersion in bi-modal oil shales
… velocity rates were analyzed with the help of a least squares curve fitting computer model, CFITIM, developed by Van Genuchten (1981). Emphasis was placed on the identification of transport mechanisms which could explain the observed asymetry of the breakthrough curves. Comparison of the column …
-
Characterization of a lithium niobate piezoelectric transformer
… Beam currents have been determined using least-squares curve fitting with experimental and modeled results. Further characterization of the beam interactions with the PT was done by examining the direct bremsstrahlung x-ray spectra that were produced and the x-ray fluorescence peaks …
-
Intermolecular potential combining rules utilizing corresponding states correlations for pure substances having nonspherical molecules
… from the data by means of a nonlinear, least squares curve fitting technique. Correlations are given for the potential parameters of each substance in terms of its critical temperature, critical volume, and acentric factor. The accuracy of these correlations is near to that of the Pitzer …
-
Mach flow angularity probe curve fitting/calibration routine
… in a flow field has been developed. Using a least squares curve fitting program, the misalignment angles of a mach flow angularity probe are determined using pressure data measured from all five orifices during a wind tunnel test. Calibration curves are then determined using a differential …
-
High-sensitivity spectral fluorescence lifetime imaging for resolving spectroscopically overlapping species
… for this purpose use analog light detection with least squares curve-fitting analysis and improvements in sensitivity are needed. To this end, a microscope has been constructed with high throughput and single-photon detection capability. The fluorescence is separated through use of a prism …
-
An experimental study on higher order waves and hydrodynamic loading on vertical surface piercing cylinders
… using a Fast Fourier Transform technique and a least squares curve fitting method to separate the wave of interest from the side effects and identify its principal parameters. Several side effects were quantified in the process. Wave forces on a vertical cylinder to second order were …
-
An Adaptive Algorithm to Identify Ambiguous Prostate Capsule Boundary Lines for Three-Dimensional Reconstruction and Quantitation
… capsule. We also present an algorithm based on a least squares curve fitting technique that uses a prostate shape equation to merge previously detected capsule parts with the curve equation to produce an approximated curve that represents the prostate capsule. We have tested our algorithms using …
-
Dynamic characteristics of pneumatic actuator and valve systems.
… presented and the results are correlated using a least squares curve fitting technique.
-
Physico-chemical studies on copolymers of 2-methyleneglutaronitrile and selected derivatives
… involvement of such complexes using a non-linear least squares curve fitting analysis of the compositions of copolymers prepared over a wide comonomer composition range. The analysis coupled with a statistical testing method reveals that in both systems, invoking complex participation does not …
-
Improving eye-gaze tracking accuracy through personalized calibration of a user's aspherical corneal model
… eye parameters by statistical modeling through least squares curve fitting. Compared to a current approach referred to here as the Hennessey's calibration method, this approach offers significant advantages, including improved, individual calibration. Through analysis and comparison of this new …
-
Real time trajectory generation and interpolation
… of the drives are not violated. Commonly used least squares curve fitting of discrete data points forces the curve to weave through the data points and results in a fluctuating toolpath. By making use of the defined basis function distributions of the NURBS control points, a higher smoothness …
-
Experimental Investigation of Temperature Effect on Uniaxial Tensile Test
… followed by graphical inspection and non-linear least-squares curve fitting. Temperature distributions were measured using a high speed data-acquisition system at a transfer frequency of 104 Hz. For tests in air, temperature rises varied from 118 to 25 °C and 75 to 3 °C for 310SS and I.F. steel …
-
Spatial and Temporal Performance Characteristics in a Two-Dimensional Human Motion Analysis System Using Digital Video Capture
… cameras produced a frame duplication artefact. Least squares curve-fitting using a sinusoidal function revealed RMS differences between 3-5% for angular position and 5-15% for angular speed compared to the captured motion data. It was shown that some digital-video cameras and computer playback …
-
Experimental Identification of Nonlinear Systems
… of the frequency-response function in a least-squares curve-fitting algorithm. The algorithm is improved by making use of experimentally known information about the location of the bifurcation points. The method is validated by using the parameters extracted to predict the force-response …
Page 1 of 2