Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 23 for “"Lge-Mri"”
-
Development of a Method for Registering Surface of Left Atrium determined by LGE-MRI to Electroanatomical Maps
… gadolinium-enhanced magnetic resonance imaging (LGE-MRI) may aid in guiding AF cardiac ablation therapy by determination of fibrosis in the LA. To locate fibrosis for cardiac ablation, however, precise registration between EAMs and LGE-MRI data is crucial. The purpose of this thesis was to …
-
Automated Left Atrium Segmentation in LGE-MRI: A Cross-Dataset Evaluation of Foundation and 3D Deep Learning Models
… gadolinium-enhanced magnetic resonance imaging (LGE-MRI) is a key modality for non-invasivevisualization of atrial fibrosis, yet quantitative interpretation of these images dependson accurate and consistent anatomical segmentation. Manual delineation remains com-mon in practice but is …
-
Left atrial parameterisation and multi-modal data analysis: application to atrial fibrillation
… enhancement magnetic resonance imaging (LGE-MRI) data, (2) a framework for obtaining a standardised two-dimensional representation of the left atrial cavity, and (3) a methodology to detect and measure the incompleteness of ablation lesions after pulmonary vein isolation (PVI). Finally, …
-
Image Processing Methods for Myocardial Scar Analysis from 3D Late-Gadolinium Enhanced Cardiac Magnetic Resonance Images
… gadolinium-enhanced magnetic resonance imaging (LGEMRI) is widely used to detect and quantify myocardial scar regions of the heart. However, due to the anisotropic spatial dimensions in 2D LGE-MR images, creating scar geometry from these images results in substantial reconstruction errors. For …
-
A Deep Learning-based Pipeline to Generate Patient-specific Anatomical Models of the Heart Using Cardiac MRI
… Cardiac magnetic resonance imaging (MRI) provides images with high-resolution and superior soft tissue contrast, rendering it as the gold standard modality for imaging cardiac anatomy. To obtain meaningful information from such image-based personalized anatomical models of the heart, …
-
Multi-Modality Correspondence to Enhance Arrhythmogenic Atrial Substrate Identification: Guiding Persistent Atrial Fibrillation Ablation Therapy
… Gadolinium-verstärkte Magnetresonanztomographie (LGE-MRI). Beide werden jedoch dadurch behindert, dass es keinen Konsens über eine präzise Methode zur Identifizierung des pathologischen Substrats gibt. Die eindeutige Identifizierung mittels Low Voltage Mapping wird erschwert, da die Auswirkungen …
-
Machine Learning Aided Analysis of Contrast-enhanced MRIs for Targeted Ablation of Atrial Fibrillation
… contrast-enhancing agents are used in 30% of all MRI (LGE-MRI) scans worldwide to improve the visibility of structures often associated with disease, such as fibrosis (scar tissue). Recent clinical studies using LGE-MRI suggest that atrial scar tissue is an important contributor to the structural …
-
SOCRATIS: Segmentation Of Cardiac Regions And Total Infarct Scar
… enhancement magnetic resonance images (LGE-MRI). Manual segmentation of scar from LGE-MRI varies in size, shape, heterogeneity, artifacts, and image resolution. The process is time consuming, and influenced by the observer's experience (bias effect). Here we propose a framework that …
-
Image-Based Modelling of the Electrophysiological and Structural Effects of Fibrosis on the Mechanisms of Atrial Fibrillation
… based on magnetic resonance imaging (MRI) from AF patients.<br/><br/>The computational model of the 3D human atria integrated the Visible Female cardiac geometry, rule-based fibre orientation, region-specific atrial electrophysiology and its changes due to AF-induced ionic remodelling. …
-
Pre-clinical Validation and Clinical Translation of Magnetic Resonance Imaging Markers To Improve Radiofrequency Ablation (RFA) Treatment of Ventricular Tachycardia
… (native T1w) and late gadolinium enhancement (LGE) magnetic resonance imaging (MRI) are used to characterize the RFA lesions following conventional clinical ablation strategies. The objective of the first experimental study was to validate the structural characteristics of the ablation lesion …
-
Biological and Social Factors Influencing Symptoms and Quality of Life in Women and Men with Atrial Fibrillation
… cardiac late gadolinium enhancement (LGE) MRI at an academic medical center in the Pacific Northwest. LA fibrosis (%), EAT volume, and EAT index were quantified using LGE-MRI, with an EAT subsample of 30 subjects. Plasma adipokines, leptin and adiponectin, were measured by enzyme …
-
Investigating left ventricular infarct extension after myocardial infarction using cardiac imaging and patient-specific modelling
… from cardiac magnetic resonance imaging (MRI) of 6 MI patients, the correlation between infarct extension and regional mechanics impairment was studied. Prior to the modelling, a 2D-4D registration-cum-segmentation framework for the delineation of LV in late gadolinium enhanced (LGE) MRI …
-
Deep Learning for Improving the Detection, Prognosis, and Treatment of Atrial Fibrillation
… gadolinium-enhanced magnetic resonance imaging (LGE-MRI). This was capable of performing segmentation and the extraction of key biomarkers including the bi-atrial chamber measurements, anatomic structure, fibrosis distribution, and wall thickness variation. The pipeline was trained and validated …
-
Cardiovascular Imaging of Myocardial Viability after Acute Myocardial Infarction
… Manganese-enhanced magnetic resonance imaging (MEMRI) could provide an assessment on cardiac structure and function as well as in vivo monitoring of intracellular calcium ion (Ca⁺²) changes. As a central regulator of cardiac contractility, intracellular Ca⁺² changes could be used to assess viable …
-
Development of native and contrast enhanced magnetic resonance imaging for the characterization of cardiovascular disease
Late gadolinium enhancement (LGEJ imaging is a widely used cardiovascular MRI technique. My work focused on developing new LGE MRI sequences to; identify plaque in the aortic vessel wall, to visualize areas of ventricular scar after myocardial infarction and pulmonary vein and atrial wall lesions …
-
Four-Dimensional Cardiac Magnetic Resonance Analysis in Patients with Atrial Fibrillation
… (4D) flow magnetic resonance imaging (MRI), enable detailed assessment of time-resolved three-dimensional blood flow within the LA. This technique allows quantitative visualization of intra-atrial flow patterns, wall shear stress, and stasis, providing novel insights into the interplay …
-
ADVANCED MRI FOR CARDIAC ASSESSMENT IN MICE
… in mice, in vivo magnetic resonance imaging (MRI) can be used to evaluate heart anatomy and function at multiple levels. Volumetric measurements of ventricle size at each phase of the heart cycle (obtained with cine MRI) can be used as a sensitive measure for heart failure. Cine MRI is applied …
-
Imaging and Therapy of Stem Cell Derived Extracellular Vesicles in a Mouse Model of Cardiac Ischaemia
… noninvasive cardiac imaging using preclinical MRI and ultrasound technologies. I tested the in vivo benefit of sEVs over a saline control when delivered intramyocardially at the site and time of ischaemia via subsequent serial assessment of cardiac function and infarct size. My results showed I …
-
Automatic Cardiac Segmentation of Complex Morphologies, Modalities and Tissues
… segmentation within magnetic resonance imaging (MRI) images, highlighting the challenges posed by complex shapes and ill-defined borders. It introduces the M&Ms-2 challenge, a substantial dataset encompassing diverse pathologies, multiple views, and various scanners. The chapter discusses the …
-
Machine Learning Based Cardiac Scar Detection in Computed Tomography
… interventions. Late gadolinium enhancement (LGE) MRI is the gold standard for scar imaging; however, there are common instances where it is contraindicated. Computed tomography angiography (CTA) is an alternative imaging modality that has fewer contraindications, fewer artefacts and is faster …
Page 1 of 2