Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 29 for “"Light Cure"”.
-
The Evaluation of Light Cure Baseplate Material
The study was undertaken to evaluate light cure resin as an alternative to a current self cure material. Light cure materials are supplied by the manufacturer ready mixed in the form of sheets, rope or gel as opposed to the raw chemicals which have to be mixed before or during use. Laboratory tests …
-
Effect of Light-Cure Initiation Time on Polymerization and Orthodontic Bond Strength with a Resin-Modified Glass-Ionomer
… this study was to examine the effect of visible light<–>cure (VLC) delay on the polymerization efficiency and orthodontic bond strength of a dual<–>cured RMGI. Methods: An RMGI light<–>cured immediately, 2.5, 5, or 10 minutes after mixing comprised the experimental groups. Isothermal and dynamic …
-
A Comparison of Bond Strength Between Three Glass Ionomer Cements Used for the Retention of Orthodontic Bands
… at 1 hour and 24 hours using laser and common light cure techniques. The sample consisted of one hundred twenty sound extracted human molars divided into 5 groups: Ketac-Cem (self-cure), Ultra Band-Lok (light-cure), Ultra Band-Lok (laser cure), 3M Experimental (light-cure) and 3M Experimental …
-
Resistencia al cizallamiento e índice adhesivo remanente (ARI) utilizando primers hidrofílico e hidrofóbico expuestos a contaminación con agua y saliva
… (Transbond™ MIP) e hidrofóbico (Transbond™ XT Light Cure Adhesive y Rely-a-bond®) sobre esmalte de dientes bovino expuestos a contaminación (agua y saliva) y sin contaminación. Materiales y Métodos: Se utilizaron 99 incisivos permanentes de bovino y se dividieron en nueve grupos de estudio, …
-
Light-Activation Influence on the Thermal Analysis of a Resin-Modified Glass-Ionomer
The acid-base and light polymerization reactions in resin modified glass ionomers (RMGI) have been shown to compete and possibly inhibit one another during early RMGI development. Earlier beginning times of light polymerization initiation may limit the acid-base reaction and if time allowed for the …
-
The influence of delayed light curing on the polymerization contraction stress and degree of conversion in dual-cured resin luting agents
… (PCS)and degree of conversion (DC) of a dual-cured resin luting agent, and 2) To determine the amount of delay in photo-initiation of the dual-cured resin cements that can achieve a reduced PCS value with the highest possible DC. The amount of PCS and DC of a dual-cured resin luting agent was …
-
Microleakage of temporary restorations in endodontically accessed teeth; thermocycling, brushing, and coating effects: an in vitro study
… (3M ESPE), 2. Ketac Molar (3M ESPE), 3. Riva Light Cure GlC (SDI). Each type of restoration had one subgroup with a coating (Cavit-Ketac Glaze, Ketac Molar- Ketac Glaze, Riva Light Cure GIC – Riva Coat) and the other without coating. Restored teeth were placed in artificial saliva at 37°C for …
-
Ličio disilikato restauracijų cementavimas: metodikos ir cementavimo medžiagos pasirinkimas /
… Excel 365. Results. Dentists frequently use dual cure cement when luting onlays and crowns (86% each) and light cure cement for veneers (74%). Dentists with less clinical experience (up to 10 years) are more likely to use preheated composite resin as a luting agent for lithium disilicate onlay …
-
Comparing the Vertical Misfit of Casts Produced By Two Verification Jigs
… with verification jigs made of acrylic resin and light cure Triad. Materials and Methods: 10 GC Pattern resin Pattern verifications jigs and 10 Triad gel verification jigs fabricated of a master cast of a mandibular model of 4 internal hex implants. A stone base was fabricated for each …
-
Polymerization shrinkage stress of light curing dental composites
… mm gap between them. The resin was injected and light cured for 20 seconds. The load curve was recorded until 5 mins after the end of light cure. The stress values were calculated in MPa from the division of contraction forced recorded at 20 s. 60 s.180 s. and 300 s. Statistical analysis was done …
-
Accuracy of Two Indirect Bonding Transfer Methods: A Three-Dimensional, In-vivo analysis
… randomly assigned to either a transparent tray light-cure or an opaque tray chemical-cure indirect bonding system. A total of 129 teeth were analyzed for the transparent tray group and 99 teeth for the opaque tray group. An intraoral scanner was used to generate three-dimension .stl models of …
-
Comparative analysis of the mechanical properties of fiber and stainless steel multistranded wires used for lingual fixed retention
… (ESRE) were polymerized employing Stickresin (Light cure enamel adhesives), the second one (ESFT) employing Flow Tain (Light cured composite), whilst the specimens for the third group (ES) were not combined with resin. All samples were loaded in tensile up to fracture in a universal tensile …
-
Assessing the Interdimensional Fit of Archwire-Bracket Slot Engagement Using Microcomputed Tomography
… retains an archwire. Using TransbondTM XT light cure adhesive by 3M Unitek, these brackets were bonded to a stone model representing the maxillary left quadrant. A .017x.025 inch nickel-titanium archwire was engaged in the bracket slots. The sample was scanned using microcomputed …
-
A Comparison of Bond Strength Between Direct and Indirect Bonding Methods
… strength from a bracket directly bonded with a light cured adhesive. Three groups of 20 teeth were used. Three different bonding materials were used to bond brackets to the teeth. The control group used a light cured, highly filled orthodontic adhesive, Transbond XT (3M/Unitek Corporation, …
-
Mitigating Distortion of Light-Polymerized Composite Trial Bases
Triad Visible Light Cure (VLC) Denture Base Material, a light-polymerizing resin material, is commonly used by clinicians to make trial bases during the fabrication of dentures and in planning the prosthetic and surgical rehabilitation of edentulous patients. A well-known drawback to this material, …
-
Effects Of Light Curing Bonding Agent With Dual Cure Cement On The Retention Of Zirconia And Lithium Disilicate Crowns: An In-Vitro Study.
… adhesive with resin cement and different light curing protocols.Methods: Sixty extracted sound non carious human teeth (second premolars) were stored in formalternate solution (FormalternateTM, Concentrate, 500 mL, Canada) and the roots were notched and mounted into acrylic resin (Yates …
-
Translucency And Stain Resistance Of A Light Cured Pontic Paste
Objectives: Light-cured pontic pastes can be applied to the internal aspect of clear retainer/aligner trays at sites of missing teeth. Ideally, the pontic tooth should appear visually opaque and resist staining. The aim of this study was to determine if the number of coats of the paste will affect …
-
Enamel Demineralization Around Bonded Orthdontic Appliances Using Resin Coatings
… fluoride. Ortho-coat is a fluoride releasing, light cure, hydrophilic resin that coats both the bracket and tooth surface preventing decalcification. The aim of this study was to investigate the barrier effect of Opalseal and Ortho-coat compared to both a fluoride varnish group and a control …
-
Efeito crônico do LED de alta potência na retina de rato wistar
Introduction: The increase in the power of light-emitting diode (LED) light cure has contributed to reduce the curing time of restorative and orthodontic procedures. However, the effect of the LED on the retina of those who make the chronic use of light units without using protection filters is …
-
Effect of Etch Time on SBS of Machinable Lithium Disilicate Glass Ceramics Using Variolink Esthetic LC
… aperture, onto the prepared ceramic surface and light cured for 60 seconds, using a 3M Elipar curing light. The bonding procedure was repeated for 3 rounds, each time varying the duration of etching: in round 1, per the manufacturer’s instructions, in round 2 a 60 second etch and in round 3 per …
Page 1 of 2