Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 12 of 12 for “"Light obscuration"”

  1. Design and analysis of the Hobby-Eberly Telescope Dark Energy Experiment bridge

    … frequency response and limit deflections and light obscuration. Considerable fabrication challenges are overcome to allow integration of precision hardware required for positioning the corrector optics to a precision of less than 5 microns along the 4-meter travel range. This thesis provides …

    texas Repository record for Design and analysis of the Hobby-Eberly Telescope Dark Energy Experiment bridge (opens in a new tab)

  2. Analyzing Photo-Electric Smoke Detector Response Based On Aspirated Smoke Detector Obscuration

    Accurate obscuration levels at the response time of photo-electric smoke detectors are needed for proper detection modeling and analysis. In recent works, obscuration meters were used to measure the obscuration level at photo-electric detector response. In this study, aspirated smoke detectors …

    maryland Repository record for Analyzing Photo-Electric Smoke Detector Response Based On Aspirated Smoke Detector Obscuration (opens in a new tab)

  3. A Functional Suitability Assessment of Aseptically Reprocessed Bromobutyl Parenteral Packaging Components

    … one orthogonal characterization technique: HIAC light obscuration, membrane microscopy, and Micro Flow Imaging, respectively. Visual inspection and dimensional analysis were also evaluated using vendor specifications for the components. Results demonstrated that reprocessed stoppers retained …

    ku Repository record for A Functional Suitability Assessment of Aseptically Reprocessed Bromobutyl Parenteral Packaging Components (opens in a new tab)

  4. DETECTION OF SIGNATURES FROM INTERNAL CONTAMINANT SOURCES USING INTELLIGENT ALGORITHMS

    … in false alarms, leading to uncertainties for flight crews. The escalating costs of diversions and growing awareness of associated health risks underscore the need for more reliable detection and discrimination from false alarms. This study harnesses advanced multi-sensor array technologies, …

    maryland Repository record for DETECTION OF SIGNATURES FROM INTERNAL CONTAMINANT SOURCES USING INTELLIGENT ALGORITHMS (opens in a new tab)

  5. An analysis of the grain refinement of magnesium by zirconium

    … samples, while an AccuSizer 770 Photozone/Light Obscuration instrument was used to measure total particle size distributions in the master alloy and grain refined samples. Transmission Electron Microscopy (TEM) was used to identify particles that likely act as suitable heterogeneous …

    alabama Repository record for An analysis of the grain refinement of magnesium by zirconium (opens in a new tab)

  6. Advancing Sub-Visible Particle Characterization in Inhaled Biologics

    … of the API. Conventional methods, such as Light Obscuration, are commonly used to quantify sub-visible particles, but often face challenges in detecting small and translucent particles. This thesis explores how continuous flow microscopy, specifically micro-flow imaging (MFI), can be used …

    chalmers Repository record for Advancing Sub-Visible Particle Characterization in Inhaled Biologics (opens in a new tab)

  7. The Scalability of Smoke Density and the Viability of New Detection Methods in Aircrafts

    … all found to follow patterns similar to that of light obscuration measurements and were thus deemed viable options for use in cargo compartments. Carbon dioxide and the loss of oxygen were detected 100-600 seconds faster than visible smoke for smoldering polyurethane and smoldering cotton tests, …

    maryland Repository record for The Scalability of Smoke Density and the Viability of New Detection Methods in Aircrafts (opens in a new tab)

  8. On the development of analytical methods for percutaneous transluminal coronary angioplasty catheters and drug eluting stents

    … of interventional medical devices. A novel light obscuration method is applied to the measurement of particulate matter during an in vitro clinical procedure in the sub-visible range of 2 to 125 µm. The methodology involves a break from the standard approach of sampling a portion of the …

    galway Repository record for On the development of analytical methods for percutaneous transluminal coronary angioplasty catheters and drug eluting stents (opens in a new tab)

  9. Comparisons of Two Different Analytical Methodologies for the Characterization of Sub-Visible Particles in Therapeutic Protein Formulations

    … testing of parenteral drug products by either light obscuration (LO) or light microscopy. According to the USP/EP, the LO method requires the use of four measurements consuming a total volume of 25 ml per sample. This large sample volume makes the compendia test not only cost-intensive for …

    ku Repository record for Comparisons of Two Different Analytical Methodologies for the Characterization of Sub-Visible Particles in Therapeutic Protein Formulations (opens in a new tab)

  10. Development of a Quality System to Control DNA, Endotoxin and Particulates as part of an Extracorporeal Bioartificial Liver Medical Device

    … down to 1μm were measured using laser light obscuration. Initially the removal of particulates from alginate as a starting material (alginate prior to encapsulation) was shown, using filtration by depth charge filter, sand bed filtration and gas solid cyclonic filtration. Encapsulated …

    ucl Repository record for Development of a Quality System to Control DNA, Endotoxin and Particulates as part of an Extracorporeal Bioartificial Liver Medical Device (opens in a new tab)

  11. Evaluation of dynamic light scattering as a technique for the routine monitoring of therapeutic proteins on stability

    … and can be used where appropriate. Dynamic Light Scattering (DLS) is one such technique, that has been described on several occasions as an early indicator of protein aggregation. Some benefits of DLS over other aggregation-monitoring techniques, is its ability to analyse proteins in their …

    cork Repository record for Evaluation of dynamic light scattering as a technique for the routine monitoring of therapeutic proteins on stability (opens in a new tab)

  12. Asymmetrical flow field-flow-fractionation in pharmaceutical analytics

    … 4, which provides an insight into multi-angle light scattering. The Theoretical Section is summarized in Chapter 5. Chapter 6 attends to the general applicability of (semi-)chromatographic AF4 in protein analysis. The correlation of cross flow progression with increased resolution was …

    lmu-germany Repository record for Asymmetrical flow field-flow-fractionation in pharmaceutical analytics (opens in a new tab)