Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 514 for “"Limit of detection (LoD)"”

  1. Bayesian Solution to the Analysis of Data with Values below the Limit of Detection (LOD)

    … (chapter III), the mixture model consisting of a censored lognormal distribution and a point mass distribution (chapter IV), and the mixture model with random effects (chapter V), for the analyses of data with values below the Limit of Detection (LOD). The Markov chain Monte Carlo methods …

    ohiolink Repository record for Bayesian Solution to the Analysis of Data with Values below the Limit of Detection (LOD) (opens in a new tab)

  2. Dual-pulse laser induced breakdown spectroscopy in the vacuum ultraviolet with ambient gas: spectroscopic analysis and optimization of limit of detection of carbon and sulfur in steel

    … to background ratio (SBR) and concomitantly the limit of detection (LOD). Three types of gases, nitrogen, argon and helium were investigated individually as ambient environment. The variation in signal gain with ambient gas pressure was measured. The feasibility study of dual-pulse (DP) LIBS) in …

    dcu Repository record for Dual-pulse laser induced breakdown spectroscopy in the vacuum ultraviolet with ambient gas: spectroscopic analysis and optimization of limit of detection of carbon and sulfur in steel (opens in a new tab)

  3. A polarization isolation method for measurement of fluorescence assays in a microfluidic system using organic electronics for application to point-of-care diagnostics

    … integrated on-chip fluorescence detector with limit of detection (LOD) of 1 nanomoles(nM) of a fluorescence dye which is 1000 times less than that reported in current literature. The on-chip fluorescence detector has been fabricated from scratch using novel organic electronic devices with a …

    ohiolink Repository record for A polarization isolation method for measurement of fluorescence assays in a microfluidic system using organic electronics for application to point-of-care diagnostics (opens in a new tab)

  4. Development of Simplified Analytical methods for In-situ Detection of Ammonia and Urea in Aqueous Solutions

    In-field analysis of nitrogen-containing compounds such as ammonia and urea remains challenging due to the limitations of conventional methods such as non-portability, the toxicity of reactants, and the need for a trained operator. This study presents a colorimetric pH detection paper-based sensing …

    calgary Repository record for Development of Simplified Analytical methods for In-situ Detection of Ammonia and Urea in Aqueous Solutions (opens in a new tab)

  5. Development and application of polyclonal and monoclonal-antibody based enzyme-linked immunosorbent assays for the analysis of neonicotinoid insecticides imidacloprid and thiamethoxam

    The sensitivity of previously developed enzyme-linked immunosorbent assay (ELISA) for imidacloprid was considerably improved with a purified polyclonal antibody and a direct competitive assay format (dcELISA). Under the optimized conditions, the half-maximal inhibition concentration (I50) and the …

    hawaii Repository record for Development and application of polyclonal and monoclonal-antibody based enzyme-linked immunosorbent assays for the analysis of neonicotinoid insecticides imidacloprid and thiamethoxam (opens in a new tab)

  6. Laser Spectroscopy Sensors for Measurement of Trace Gaseous Formaldehyde

    … water extraction and chemical reactions that are often required in conventional methods. In this LIF approach, the third harmonic of a nontunable Nd:YAG laser at 355 nm is used as a selective excitation wavelength for formaldehyde. Studies at alternative excitation wavelengths have also been …

    ohiolink Repository record for Laser Spectroscopy Sensors for Measurement of Trace Gaseous Formaldehyde (opens in a new tab)

  7. Analysis of Bivariate Censored Longitudinal Data: A Case Study

    Laboratory measurements that are below the limit of detection (LOD) are common in continuous longitudinal data in the biomedical sciences. The presence of these left-censored values, or non-detects (NDs), complicates the statistical analysis of such data since improper treatments of NDs may lead to …

    washington Repository record for Analysis of Bivariate Censored Longitudinal Data: A Case Study (opens in a new tab)

  8. Luminescence detection in eVOLVER for autonomous bioreactor control

    We describe the design, implementation, and limitations of a luminescence detection system for the eVOLVER parallel benchtop bioreactor system. This addition aims to expand eVOLVER's functionality, particularly in Phage Assisted Continuous Evolution (PACE) platforms by allowing real-time automated …

    bu Repository record for Luminescence detection in eVOLVER for autonomous bioreactor control (opens in a new tab)

  9. Desenvolvimento de método analítico para quantificação de lactonas macrocíclicas em músculo bovino por cromatografia líquida de alta eficiência acoplada à espectrometria de massas (LC-MS/MS)

    The control of chemical residues in foods of animal origin is extremely important to guarantee the quality of the product and, therefore, the health of the consumer. Macrocyclic lactones are veterinary drugs approved for use and have a maximum residue limit in food. National and international …

    brazil-uerj Repository record for Desenvolvimento de método analítico para quantificação de lactonas macrocíclicas em músculo bovino por cromatografia líquida de alta eficiência acoplada à espectrometria de massas (LC-MS/MS) (opens in a new tab)

  10. Development of a Non-Faradaic Impedimetric Biosensor Based on Reduced Graphene Oxide for the Detection of Brain-Derived Neurotrophic Factor (BDNF)

    Neurological disorders affect millions of people worldwide. In the case of Alzheimer’s disease (AD), the rising number of cases significantly increases global healthcare costs. Therefore, early detection of biomarkers at the onset of the disease is essential for early diagnosis. This study presents …

    denver Repository record for Development of a Non-Faradaic Impedimetric Biosensor Based on Reduced Graphene Oxide for the Detection of Brain-Derived Neurotrophic Factor (BDNF) (opens in a new tab)

  11. Comparing Machine Reading Substitution To Alternative Statistical Treatment Methods For Left-Censored Data: Considerations To Limit Bias In Maternal-Infant Research On Environmental Chemicals (MIREC) Study

    … refers to missing data on the left side of a distribution due to falling below a threshold such as the limit of detection (LOD). A variety of methods for treatment of this issue have been proposed in the context of environmental datasets. This thesis compares five approaches; single-value …

    carleton Repository record for Comparing Machine Reading Substitution To Alternative Statistical Treatment Methods For Left-Censored Data: Considerations To Limit Bias In Maternal-Infant Research On Environmental Chemicals (MIREC) Study (opens in a new tab)

  12. Entwicklung einer sensitiven HPLC-Methode zur Bestimmung der Kontamination von Oberflächen mit Gemcitabin aus Wischproben

    Monitoring of work surfaces in health-care settings still shows detectable levels of antineoplastic drugs. The implementation of recent guidelines for the protection of healthcare workers’ safety and health has already resulted in decreased contamination levels of antineoplastic drugs, although …

    lmu-germany Repository record for Entwicklung einer sensitiven HPLC-Methode zur Bestimmung der Kontamination von Oberflächen mit Gemcitabin aus Wischproben (opens in a new tab)

  13. Signal processing and amplifier design for inexpensive genetic analysis instruments

    … Tool Kit (TTK). By using a photodiode instead of photomultiplier tubes in the optical detection, the AML has lowered the cost and size compared to commercial LIF-CE products. However, maintaining an adequate signal-to-noise (SNR) and limit of detection (LOD) is a challenge. By implementing a …

    alberta Repository record for Signal processing and amplifier design for inexpensive genetic analysis instruments (opens in a new tab)

  14. Microfluidics Sensor to Detect Water Salinity and Bacteria Using Optical and Electrical Methods

    Contaminants of various sources pollute waters worldwide and pose serious health issues to humans. Thereby, regular monitoring of the water quality is crucial. In this respect, this thesis aims to design an inexpensive microfluidic-based sensor with two microwire electrodes to narrow the gap …

    york Repository record for Microfluidics Sensor to Detect Water Salinity and Bacteria Using Optical and Electrical Methods (opens in a new tab)

  15. Antibody-based detection and quantification of Pectobacterium carotovorum ssp. carotovorum

    … (Pcc) is implicated in the destruction of ornamental plants in greenhouse recirculating systems. PCR-based detection and quantification of Pcc requires expensive instrumentation and knowledgeable users. This thesis describes the production of polyclonal antibodies and a single-domain …

    guelph Repository record for Antibody-based detection and quantification of Pectobacterium carotovorum ssp. carotovorum (opens in a new tab)

  16. Nanomaterial-based Electrochemical Immunosensors for the Detection of Cardiovascular Biomarkers

    Cardiovascular disease is one of the leading causes of premature death worldwide, and the determination of C-reactive protein (CRP) from human serum is of vital importance for the diagnosis of the disease. For this study, we have developed an electrochemical immunosensor based on onion-like …

    guelph Repository record for Nanomaterial-based Electrochemical Immunosensors for the Detection of Cardiovascular Biomarkers (opens in a new tab)

  17. Nanoporous Microcantilevers with Plasmonic Absorbers for Photothermal Infrared Spectroscopy

    … high power infrared (IR) spectroscopy. For standoff spectroscopy, a plasmonic enhanced AAO cantilever was shown to improve characteristic peak depth 10-fold and 7-fold compared to silicon and AAO bimetallic cantilevers, respectively. The limit of detection (LOD) of the plasmonic AAO cantilever …

    calgary Repository record for Nanoporous Microcantilevers with Plasmonic Absorbers for Photothermal Infrared Spectroscopy (opens in a new tab)

  18. Applications of capillary electrophoresis in the analysis of natural products

    This work focuses on the analytical applicability of capillary electrophoresis (CE) in the analysis of natural products. To obtain enough selectivity and sensitivity, various detection methods--- optical, electrochemical and hyphenating detections --- were tested and applied in this thesis. Five …

    nus Repository record for Applications of capillary electrophoresis in the analysis of natural products (opens in a new tab)

  19. Novel Technologies for Highly Sensitive Protein Quantification in Blood Plasma and Extracellular Vesicles

    Proteins and extracellular vesicles (EVs) in biofluids can be used as crucial biomarkers to diagnose diseases early, which can be lifesaving. This thesis describes the development of sensitive and simple technologies to detect and quantify proteins and EVs in human blood plasma. Firstly, a method …

    guelph Repository record for Novel Technologies for Highly Sensitive Protein Quantification in Blood Plasma and Extracellular Vesicles (opens in a new tab)

  20. Αξιολόγηση μεθόδου ποσοτικού και επιβεβαιωτικού προσδιορισμού ενδογενών αναβολικών στεροειδών σε ούρα αθλητών

    … (inter-day precision), το όριο ανίχνευσης ( limit of detection, LOD) και ποσοτικοποίησης (limit of quantification,LOQ), καθώς και την συνδυασμένη τυπική αβεβαιότητα της μεθόδου uc. Με βάσει τα αποτελέσματα επικύρωσης, οι δύο μέθοδοι κρίθηκαν κατάλληλες και πληρούν τις προδιαγραφές του …

    athens Repository record for Αξιολόγηση μεθόδου ποσοτικού και επιβεβαιωτικού προσδιορισμού ενδογενών αναβολικών στεροειδών σε ούρα αθλητών (opens in a new tab)

Page 1 of 26