Data Processing Methods And Their Effects On The Limits Of Agreement And Reliability Of Automated Submaximal Threshold Calculations
… intensity constitutes an important component of exercise prescription, but its individualization poses challenges. Previous research underscores the greater efficacy of physiological threshold-based cardiovascular exercise intensity prescription, when compared to standardized percentages of …
-
Συσχέτιση της εκτίμησης της ταχύτητας μετάδοσης του σφυγμικού κύματος ανάμεσα στις συσκευές Arteriograph και Complior σε ασθενείς με καρδιαγγειακά νοσήματα
Purpose: Pulse wave velocity (PWV) is a marker of arterial stiffness with major prognostic value. We compared Arteriograph and Complior devices with the Mobil-O-Graph for assessment of PWV and central systolic blood pressure (cSBP).Materials and Methods: We studied 316 consecutive subjects (age: …
-
Validation of Optical Coherence Tomography-Based Crystalline Lens Thickness Measurements in Children
<p>The purpose of this study was to evaluate the validity and repeatability of crystalline lens thickness measurements obtained by anterior segment optical coherence tomography (OCT). Optical coherence tomography utilizes infrared light and partial-coherence interferometry to produce a …
-
Gestational weight gain and birth outcomes in U.S. and Tanzanian populations
… age births, but gaps remain in our understanding of these relationships. Study 1 evaluated predictors and outcomes associated with area under the gestational weight gain curve. Compared to the middle quintile, the highest quintile of accumulated pound-days was associated with a decreased hazard of …
-
A Validation Study: Fitbit Charge 2 Heart Rate Measurement at Rest and During Cognitive-Emotional Stressors
Previous studies emphasize concurrent validity of wearable devices during physical activity. We investigate device agreement between Fitbit Charge 2 (FBC2) Heart Rate (HR) and electrocardiography (ECG) under sedentary conditions. In a sample of 32 post-secondary students, agreement was observed …
-
The Reliability and Validity of Measuring Devices for Measuring Mechanical Power
The Reliability and Validity of Measuring Devices for Measuring Mechanical Power The primary purpose of this paper is to validate a 3-D motion capture system as a reliable and valid measurement tool to be used in the practical setting for measuring bar velocity and mechanical power output. One …
-
Methods for determining lung function from tracer gas concentrations
… (FRC) or the ventilation-volume homogeneity of ventilated patients has been a long held goal. Such measures have the potential to greatly improve the treatment of patients by preventing ventilator related lung injuries. Many methods have been proposed, but none have seen routine clinical use. …
-
Three dimensional body imaging for assessment of body composition
… photonic imaging devices for assessment of body size and shape. In aim one, laser imaging measurements of circumference, volume, and % fat were examined in 70 women. Bland-Altman analysis indicated minimal error in girth of the waist and hip by laser imaging as compared to tape measure …
-
Monitoring des zerebralen Sauerstoffpartialdrucks - Vergleich zweier Mikrosonden -
… gewonnen. Zur Messung des zerebralen Sauerstoffpartialdrucks (PbrO2) wurde neben dem Goldstandard der Licox-Sonde CC1.SB (LX, Integra Neuroscience, France) eine neue Sonde - die Neurovent-PTO Sonde (NV, Raumedic, Deutschland) vorgestellt. Bisher gab es keine prospektiven Daten über den …
-
LungFIT : validating a smartphone application for pulmonary rehabilitation
… Obstructive Pulmonary Disease (COPD) symptoms of dyspnea, exercise intolerance, and reduced health related quality of life are best treated with pulmonary rehabilitation (PR). Despite benefits, transportation, availability of PR programs, and social support barriers limit PR access. …
-
Noninvasive evaluation of cardiac function using Computed Tomography and Magnetic Resonance Imaging
Objectives To evaluate the accuracy of computed tomography (CT) in the assessment of left ventricular (LV) function and compare with magnetic resonance imaging (MRI). Methods We have systematically reviewed MEDLINE, EMBASE, and ISI Web of Science. The inclusion criteria were: ejection fraction …
-
Nutzen des kapillären PO2 in der Diagnostik von hypoxämischen COPD-Patienten
… (PaO2) with capillary (PcO2) partial pressure of oxygen in hypoxemic COPD patients because capillary blood gas analysis (CBG) is increasingly being used as an alternative to arterial blood gas analysis (ABG) in a non-intensive care unit setting, although the agreement between PcO2 and PaO2 has …
-
Accuracy and reliability of single camera measurements of ankle clonus and quadriceps hyperreflexia
… provide valid and reproducible measurements of ankle clonus and quadriceps hyperreflexia. However, measuring the PFRTA and QRTA requires high fidelity motion capture systems that are limited to laboratory settings by cost and complexity. The aim of this study was to evaluate a simple, …
-
Estimation of gestational age by the use of fetal parameters : placentome, femur length, and biparietal diameter : a dissertation presented in partial fulfillment of the requirements for the degree of Master of Veterinary Studies at Massey University, Institute of Veterinary, Animal and Biomedical Sciences, Massey University, Palmerston North, New Zealand
… involved 23 beef cows and 60 dairy cows. The aim of the study was to test and assess the agreement between actual gestational age and that predicted using a model developed in previous studies based on placentome length (gestational age = placentome*2.88 - 6.11; Adeyinka et al., (2014) and to …
-
Validity of six field and laboratory methods for measurement of body composition in 10-14 year old boys
OBJECTIVE; The primary objective of this study was to determine the validity of the following six body composition measurement methods against a 3-component reference method: total body water (TBW) by isotope dilution; air displacement plethysmography (BODPOD); estimation from body density using …
-
Respiratory monitoring by inductive plethysmography in unrestrained subjects using position sensor-adjusted calibration
… (RIP) is promising for noninvasive monitoring of breathing patterns in unrestrained subjects. However, its use has been hampered by requiring recalibration after changes in body position. OBJECTIVES: To facilitate RIP application in unrestrained subjects, we developed a technique for adjustment …
-
Validierung der nicht-invasiven Hämoglobinmessung Masimo SpHb bei Frauen zur elektiven Sectio caesarea
… bereits validierten Messmethoden wie dem Point-of-Care Gerät (POC-Hb) und dem Hämatologie-Analysator (Labor-Hb) im Labor. Unsere Hypothese lautet, dass das durch die nicht-invasive Messung ermittelte SpHb unter elektiver Sectio caesarea mit dem invasiv bestimmten Labor-Hb und POC-Hb …
-
The Evaluation of an Instrumented Paddle Device for Analysing Kayak Sprint Performance
… instrumented equipment has unlocked new methods of quantifying and analysing performance. While some research has identified key biomechanical factors associated with performance, there is limited information available from on-water paddling and from new instrumented paddle devices. Thus, this …
-
Comparison of Body Composition Assessment Techniques in Older Adults
… health assessments in older adults. The purpose of this study was to evaluate percent body fat (%BF) estimations in older adults by the Tanita, a two-compartment model (Siri 2-C) and dual energy x-ray absorptiometry (DXA) compared to a three-compartment model (Lohman 3-C). Fifty-two females and …
-
The revised digital transcutaneous PCO2/SpO2 Ear Sensor is a reliable noninvasive monitoring tool in patients after cardiac surgery
OBJECTIVE: The aim of this study was to validate the revised SenTec V-Sign 2 sensor (SenTec AG, Therwil, Switzerland) for combined noninvasive continuous assessment of pulse rate, pulse oximetry (SpO(2)), and transcutaneous carbon dioxide tension (PtcCO(2)) in adults after cardiac surgery. DESIGN: …