Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 20 for “"Linac-MR"”

  1. Intrafractional Tumour-Tracked Irradiation using a Linac-MR

    … mobile tumours. By utilizing the intrafractional MR imaging feature of linac-MR, this thesis seeks to develop a direct, non-surrogate based intrafractional tumour tracking system, and physically demonstrate its feasibility by delivering highly conformal dose to a moving target undergoing simulated …

    alberta Repository record for Intrafractional Tumour-Tracked Irradiation using a Linac-MR (opens in a new tab)

  2. Surface and Buildup Dose Effects in a Linac-MR

    Magnetic resonance imaging (MRI) can visualize solid tumours in real time and its integration with a linear accelerator offers the possibility to track tumours during irradiation. However, irradiating a patient inside a linac-MR poses several challenges. MRI uses radiofrequency (RF) coils to …

    alberta Repository record for Surface and Buildup Dose Effects in a Linac-MR (opens in a new tab)

  3. Receive Radio-Frequency Coils for a Parallel B0 Linac-MR

    The rotating B0 linac-MR is a new type of radiotherapy treatment machine that combines radiation delivery from a linear accelerator (linac) with a magnetic resonance imaging (MRI) system for real-time tumour tracking. This kind of combined technology aims to achieve tighter margins in cancer …

    alberta Repository record for Receive Radio-Frequency Coils for a Parallel B0 Linac-MR (opens in a new tab)

  4. Real-Time MLC Control and Latency Characterization on a Linac-MR

    … therapeutic ratios. Magnetic resonance imaging (MRI) guided implementations on linac-MR (LMR) systems are particularly promising due to superior soft-tissue contrast and the absence of imaging dose. However, inherent system latencies in MRI-based tracking arising from image acquisition, image …

    alberta Repository record for Real-Time MLC Control and Latency Characterization on a Linac-MR (opens in a new tab)

  5. Characterization of Radiation Induced Current in RF coils of Linac-MR Systems

    Real-time MR imaging of the cancer patients undergoing external beam radiation treatment represents the next generation in image guided radiotherapy. However, the radio frequency (RF) coil of the MRI is exposed to the pulsed radiation of the linear accelerator in the systems where a medical linear …

    alberta Repository record for Characterization of Radiation Induced Current in RF coils of Linac-MR Systems (opens in a new tab)

  6. Three dimensional simulation and magnetic decoupling of the linac in a linac-MR system

    … integrating an in-line 6 MV linear accelerator (linac) to a magnetic resonance (MR) imager in either a parallel or transverse configuration. In either configuration, magnetic interference in the linac is caused by its immersion in the magnetic fringe fields of the MR imager. Thus in order to …

    alberta Repository record for Three dimensional simulation and magnetic decoupling of the linac in a linac-MR system (opens in a new tab)

  7. Tumor Autocontouring and Motion Prediction for Non-Invasive Intrafractional Tumor-Tracked Radiotherapy on a Linac-MR

    … healthy tissues. The recently developed hybrid linac-MR systems are capable of intrafractional MR imaging and concurrent delivery of therapeutic beam. These features of linac-MR systems enable direct monitoring and tracking of the tumor in real time, allowing for non-invasive intrafractional …

    alberta Repository record for Tumor Autocontouring and Motion Prediction for Non-Invasive Intrafractional Tumor-Tracked Radiotherapy on a Linac-MR (opens in a new tab)

  8. The performance and magnetic shielding of a 6 MV in-line linac in a parallel linac-MR configuration

    … the integration of a linear accelerator (linac) with a magnetic resonance (MR) imager has been proposed. This thesis presents work that investigated performance and magnetic shielding of a linac in the presence of parallel magnetic flux densities. This work used computer simulations and …

    alberta Repository record for The performance and magnetic shielding of a 6 MV in-line linac in a parallel linac-MR configuration (opens in a new tab)

  9. Design and simulation of a short, 10 MV, variable energy linear accelerator for use in linac-MR systems

    Hybrid linac-MR devices are currently being designed and constructed by several groups around the world which combine a linear accelerator with an MRI in order to enable real-time 3D imaging to visualize tumor movement during external beam radiotherapy treatments. Each of the current systems is …

    alberta Repository record for Design and simulation of a short, 10 MV, variable energy linear accelerator for use in linac-MR systems (opens in a new tab)

  10. Skin Dose in Longitudinal and Transverse Linac-MRIs using Monte-Carlo and realistic 3D MRI field models

    The integration of a clinical linear accelerator (linac) with a magnetic resonance imaging (MRI) system would provide real-time tumor tracking. The magnetic fields of linac-MR systems modify the path of contaminant electrons in photon beams, which alters patient skin dose. In this work, we used …

    alberta Repository record for Skin Dose in Longitudinal and Transverse Linac-MRIs using Monte-Carlo and realistic 3D MRI field models (opens in a new tab)

  11. Lung Patient Treatment Plan Optimization in the Presence of Magnetic Fields

    The integration of clinical linear accelerators (linacs) with magnetic resonance imaging (MRI) systems represent the next generation of image guidance technologies in radiotherapy. Linac-MR systems have several potential advantages over the current X-ray based state-of-the-art image guidance …

    alberta Repository record for Lung Patient Treatment Plan Optimization in the Presence of Magnetic Fields (opens in a new tab)

  12. Real Time Tracking of Lung Tumours Using Low Field MRI: A Feasibility Study

    … work is to evaluate the feasibility of low field MR based real time lung tumour tracking, a promising application of proposed linac-MR system. In this work, motion phantoms replicating low field MR contrast parameters for thoracic anatomy of lung cancer patients are imaged with fast imaging …

    alberta Repository record for Real Time Tracking of Lung Tumours Using Low Field MRI: A Feasibility Study (opens in a new tab)

  13. Ensembles of Neural Networks for Tumour Motion Prediction

    … can be initiated sufficiently in advance. For MR-based tracking, this latency is relatively long compared to other imaging techniques. Accurate motion prediction therefore requires a more sophisticated approach than those used for short-latency hardware. A novel application of long short-term …

    alberta Repository record for Ensembles of Neural Networks for Tumour Motion Prediction (opens in a new tab)

  14. Dose Response of Selected Radiation Detectors in a Magnetic Field

    With the advent and development of hybrid Linac-MR technology, we will be able to track and treat lesions in real time. This will permit the narrowing of radiotherapy margins and escalation of dose, augmenting the therapeutic outcome of radiotherapy. The addition of a magnetic field to the …

    alberta Repository record for Dose Response of Selected Radiation Detectors in a Magnetic Field (opens in a new tab)

  15. Optimization of a Non-axial Magnet Design for a Hybrid Radiation Treatment and MR Imaging System

    A prototype rotating hybrid magnetic resonance (MR) imaging system and linac has been developed to allow for simultaneous imaging and radiation delivery parallel to B_0. However, the design of a compact magnet capable of rotation in a small vault with sufficient patient access and a typical …

    alberta Repository record for Optimization of a Non-axial Magnet Design for a Hybrid Radiation Treatment and MR Imaging System (opens in a new tab)

  16. Time Domain Principal Component Analysis for Rapid, Real-Time 2D MRI Reconstruction from Undersampled Data

    Hybrid Linac-MR systems are becoming more mainstream for use in external beam radiotherapy treatments for cancer patients. The addition of an MR scanner to a linear accelerator (Linac) can allow for real-time structure tracking (such as a tumour) and on-the-fly adjustments of the radiation beam. …

    alberta Repository record for Time Domain Principal Component Analysis for Rapid, Real-Time 2D MRI Reconstruction from Undersampled Data (opens in a new tab)

  17. Measurements of radiation induced currents in RF coil conductors

    The integration of a clinical linear accelerator (linac) with a magnetic resonance imager (MRI) will offer real time images during treatment, making tumor tracking possible. One of the challenges of the integration is removing any mutual interference between the two systems. Methods of removing or …

    alberta Repository record for Measurements of radiation induced currents in RF coil conductors (opens in a new tab)

  18. Highly Accelerated MRI: Prior Data Assisted Compressed Sensing for Lung Tumour Tracking

    Hybrid magnetic resonance imaging (MRI) and radiation therapy devices are capable of imaging in real-time to track intrafractional lung tumour motion during radiotherapy. In the real time tumour tracking treatment scheme, MR images are acquired in real time, then the tumour target is localized …

    alberta Repository record for Highly Accelerated MRI: Prior Data Assisted Compressed Sensing for Lung Tumour Tracking (opens in a new tab)

  19. Magnet Design and Optimization for an Integrated Linac-MRI System

    A promising approach to the development of an integrated system for magnetic resonance imaging-guided radiotherapy involves the rigid coupling of a medical linear accelerator to a rotating biplanar magnet assembly. Through near real-time volumetric imaging during irradiation, this hybrid system …

    alberta Repository record for Magnet Design and Optimization for an Integrated Linac-MRI System (opens in a new tab)