Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 31 for “"Line outage"”.
-
IMPROVED LINE OUTAGE DETECTION USING SYNCHROPHASOR MEASUREMENTS
… One such application is the detection of line outages in remote or unobserved parts of the system. Two such methods of line outage detection are examined. First, principal component analysis is used to show that highly accurate line outage detection is possible. Using concepts similar to …
-
Quickest change detection with applications to line outage detection
… change detection (QCD) theory in the problem of line outage detection and identification. We start by discussing fundamental results of sequential hypothesis testing and QCD, and by proposing an algorithm for the QCD setting under transient dynamics. Following, we apply these results in the line …
-
A Line Outage Study for Prediction of Static Power Flow Redistribution
Transmission line is a crucial role in power transmission network which connects generating units to consumers. Some unpredicted failure events such as lightening or system faults can cause transmission line tripped, which may bring about a large interruption to the system and causes damage. When …
-
POWER SYSTEM TRANSMISSION LINE OUTAGE DETECTION AND IDENTIFICATION: A PHYSICS-INFORMED DATA-DRIVEN APPROACH
… three methods for real-time power system line outage detection and identification. (1) Using voltage phase angle data collected from PMUs, a real-time dynamic outage detection scheme based on alternating current (AC) power flow model and statistical change detection theory is proposed. The …
-
Small signal analysis of power systems: Eigenvalue tracking method and eigenvalue estimation contingency screening for DSA
… second part of this dissertation develops a new line outage screening method for dynamic security analysis (DSA). The new screening method extends the use of distribution factors commonly used in static security analysis (SSA) to DSA by using the factors with eigenvalue sensitivities to estimate …
-
Real-time power system topology change detection and identification
… assumed to be known. Instead of relying on offline models as with traditional methods, the proposed method is model-free, and exploits the high-speed synchronized measurements provided by phasor measurement units (PMUs). In this framework, a statistical quickest change algorithm is applied to …
-
Synchronized measurement data conditioning and real-time applications
… of generation trip/load shedding and line outage events detection and localization based on high-density PMU measurements are investigated in Chapters 3 and 4 respectively. Four different types of abnormal synchronized measurements are identified from the PMU measurements of a power …
-
Identification of Critical Lines for Power System Operational Reliability Assessment
… reliably. Identifying the stressed or critical line or lines to ensure successful power transmission is crucial. Three critical line identification methods are developed. One method is based on large-scale sensitivity analysis when a line outage becomes unsolvable. The other two methods try to …
-
Data analysis of cascading outages using historical data to mitigate blackouts
… transmission system is a sequence of dependent outages that successively weakens the transmission system. It is caused by initial outages and then propagates as a series of dependent outages. Cascading is one of the main causes of blackouts in high voltage transmission networks. Utilities are …
-
Load Flow and Contingency Analysis in Power Systems
… with a graphic system which displays a single line diagram of the system on the graphic screen along with relevant data and informs the operator of any change by flashing the faulted bus or the line outage.
-
Development of a Fault Detection Model for Cyber Physical Power System
… intruding in the SG is considered the effect of line outages on SG is discussed when there is an attack from any hacker that altered the information of phasor measurement unit (PMU). Power World Simulator is used to simulate IEEE 13-Bus and 39-Bus systems, having renewable energy generators to …
-
Simplified reliability calculations for distribution systems
… and includes 69kV and 161kV transmission line outage rates and durations and data applicable to 23.9kV, 69kV and 161kV substation components.</p><p>Although the results of this study indicate that a Main and Transfer Bus design with oil circuit breaker similar to existing 69kV designs …
-
Flexible AC transmission system compensation on a utility transmission system
… to the McCullough-Arden #2 230kV transmission line will increase bulk power transfers into this area by 108 MW while mitigating a line outage and releasing increased power flows on a critically loaded line. This study also shows that the power system modeled will reach a steady-state condition …
-
Fast power network detection of topology change locations using PMU measurements
… be continuously updated for the purpose of on-line analysis. Several topology processing schemes have been developed in the literature to accomplish this task. The majority of these schemes process breaker statuses to detect changes in system topology. Transformer tap positions as well as …
-
Real-time power system operational reliability tools
… of the system, which is typically obtained offline. As such, the effectiveness of these tools is highly dependent on the accuracy of the model from which such sensitivities are computed, which may be compromised due to erroneous input parameters, undetected topology changes, and changes in …
-
Reliability of electric generation with transmission constraints
… to 1) calculate the cumulative probabilistic line flows from random generator failures and 2) perform load-generator reductions to remove line overloads. The additional EUE and LOLP due to transmission constraints is calculated. New piecewise-quadratic (PQ) convolution methods are used to …
-
H2 Control for Improved Stability of Multi-area Electric Power System with High Levels of Inverter-Based Generation
… (RBRM) that accounts for the probability of a line outage versus the severity of impact. This allows system planners to judiciously allocate expenses for reliability improvements based on the greatest economic benefit. The second approach is the synchrophasor validation method (SVM) which …
-
Measurement-based tools for power system monitoring and operations
This thesis proposes several online power system monitoring and operations tools that leverage real-time measurements with little or no reliance on models obtained offline. Instead of relying on offline models, which can be grossly inaccurate, as in conventional power system monitoring and …
-
On-line Monitoring and Oscillatory Stability Margin Prediction in Power Systems Based on System Identification
… requiring artificial disturbances (e. g. a line outage), allowing these critical modes to be used as an on-line index, which is referred here to as System Identification Stability Indices (SISI) to predict the closest oscillatory instability. The SISI is not only independent of system models …
-
Ecological Uniqueness for Understanding Component Importance in Power Grids
… These engineering methods include the Normalized Line Outage Distribution Factor (NLODF) and the Topological and Impedance Element Ranking metric (TIER), for transmission line analysis, and the Controllability Index (CI) and centrality measures of betweenness centrality (BC), degree centrality …
Page 1 of 2